Locking set MGB-L2...-PN... (guard locking by solenoid force) with 3 control elements, 7/8" and M12 plugs
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850, illuminated
- 2 illuminated pushbuttons
- including adhesive labels
- Connection via 7/8" and M12 plugs
- Pre-assembled on mounting plates
- Integrated Profinet RT switch
- Unicode
Description
Profinet connection
7/8" plugs according to ANSI/B93.55M-1981 and M12 plugs (d-coded) according to IEC 61076-2-101
Profinet RT switch
Point-to-point topology network structure due to integrated RT switch.
Flexible use as interlocking or guard locking
By means of the corresponding evaluation of the safe device data by the control system, use can be as either interlocking or guard locking (with or without monitoring).
Illuminated emergency stop
Emergency stop with illumination that can be controlled as required.
Dimensional drawings
Technical data
Approvals
Handle modules MGB-H-AA1A2-L-106221 (Order no. 106221)
Mechanical values and environment
Installation orientation | Door hinge DIN left |
Degree of protection | IP65 |
Ambient temperature | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Miscellaneous
Product version number | V3.0.0 |
Additional feature | with mounting plate |
Locking modules MGB-L2B-PNA-L-121863 (Order no. 121863)
Workspace
Secured switch-off distance sar | |
Door position | max. 65 mm |
Operating and display elements
Occupancy diagram | |
L0 | |
B1 |
Item | Color | Extras | Switching element | Slide-in label | Note slide-in label | Version | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
90 | 1NO | Illuminated pushbutton | |||||||
93 | 2 PD | Emergency stop illuminated | |||||||
95 | 1NO | Illuminated pushbutton |
Electrical connection values
Connecting cable | |
Ethernet | Profinet I/O cable, at least cat. 5e |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
maximum feed-in current in the connection block | |
X1, X2 | max. 4000 mA |
Safety class | III |
Current consumption | max. 500 mA |
Transponder coding | Unicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Power supply X1 | |
Fuse | |
external | min. 1 A slow blow |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system) |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Mechanical values and environment
Connection type | |
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e | M12, D-coded, screened (X4 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) |
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e | M12, D-coded, screened (X3 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) |
7/8" Power (X2 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) | |
7/8" Power (X1 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) | |
Installation orientation | Door hinge DIN left |
Switching frequency | 0.25 Hz |
Mechanical life | |
1 x 10⁶ | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
Response time | |
Door position | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Guard locking | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Emergency stop / machine stop | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Bolt position | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP54 |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Locking force FZh | 2000 N |
Guard locking principle | Open-circuit current principle |
Miscellaneous
Slide-in label | |||||||
| |||||||
Product version number | V3.30.10 | ||||||
Additional feature | incl. lens set, ID no. 120344 |
Interface
Bus data protocol | Profinet (IEC 61158 type 10) |
Safety data protocol | Profisafe (IEC 61784-3-3) |
Date interface | |
Ethernet |
Components
106221
MGB-H-AA1A2-L-106221
Handle module MGB-H-...
MGB-H-AA1A2-L-106221
Handle module MGB-H-...
- Intelligent bolt tongue
- Lockout mechanism
- Door handle
- Mounting plate
121863
MGB-L2B-PNA-L-121863
Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) with 3 control elements, 7/8" and M12 plugs
MGB-L2B-PNA-L-121863
Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) with 3 control elements, 7/8" and M12 plugs
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850, illuminated
- 2 illuminated pushbuttons
- including adhesive labels
- Connection via 7/8" and M12 plugs
- Pre-assembled on mounting plates
- Integrated Profinet RT switch
- Unicode
Accessories
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2123624
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001506
Version
Language
Size
0,1 MB
Instructions
Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type B
Doc. no.
Version
Language
Size
Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type B
Doc. no.
2115174
Version
03/24
Language
Size
3,9 MB
Betriebsanleitung Sicherheitssysteme MGB-L..B-PN.-… (PROFINET) und mit Datenstruktur Typ B
Doc. no.
2115174
Version
03/24
Language
Size
3,9 MB
Other Documents
Application examples
Approvals and certificates
DGUV
Doc. no.
Version
Language
Size
DGUV
Doc. no.
Version
Language
Size
0,8 MB
ProfiNET
Doc. no.
Version
Language
Size
ProfiNET
Doc. no.
Version
Language
Size
0,2 MB
ProfiNET
Doc. no.
Version
Language
Size
0,2 MB
TUEV Süd München M6A Zertifikat
Doc. no.
Version
Language
Size
TUEV Süd München M6A Zertifikat
Doc. no.
Version
Language
Size
0,3 MB
c UL us
Doc. no.
Version
Language
Size
c UL us
Doc. no.
Version
Language
Size
0,7 MB
Sales documents
Multifunctional Gate Box MGB
Doc. no.
Version
Language
Size
Multifunctional Gate Box MGB
Doc. no.
106109
Version
10-02/18
Language
Size
21,7 MB
Multifunctional Gate Box MGB
Doc. no.
109155
Version
10-02/18
Language
Size
21,7 MB
Multifunctional Gate Box MGB
Doc. no.
114433
Version
10-02/18
Language
Size
8,2 MB
Multifunctional Gate Box MGB
Doc. no.
106108
Version
10-02/18
Language
Size
8,2 MB
多功能系统安全控制系统 MGB
Doc. no.
155883
Version
10-02/18
Language
Size
8,3 MB
Multifunctional Gate Box MGB
Doc. no.
121652
Version
10-02/18
Language
Size
8,0 MB
CAD data
Ordering data
Ordernumber | 121864 |
Item designation | MGB-L2HB-PNA-L-121864 |
Gross weight | 5,842kg |
Customs tariff number | 85371098 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |