EUCHNER – More than safety.
EUCHNER – More than safety.

MGB-L2HECB-PN-L-105284 (Order no. 105284)

Locking set MGB-L2...-PN... (guard locking by solenoid force) with 11 controls and indicators, push-pull plug, RC12

  • Guard locking with guard lock monitoring
  • Emergency stop according to ISO 13850
  • 8 illuminated pushbuttons
  • Operating mode selector
  • 1 indicator
  • including adhesive labels
  • Push-pull plug
  • including terminal plug for enabling switch (RC12, 12-pin)
  • Pre-assembled on mounting plates
  • Integrated Profinet RT switch
  • With escape release
  • Multicode
MGB-L2HECB-PN-L-105284 (Order no. 105284)

Description

Profinet connection

Connection via push-pull plugs according to IEC 61076-3-117

Profinet RT switch

Point-to-point topology network structure due to integrated RT switch.

Flexible use as interlocking or guard locking

By means of the corresponding evaluation of the safe device data by the control system, use can be as either interlocking or guard locking (with or without monitoring).

Escape release

The escape release enables people accidentally shut in to open the guard locked door from the danger zone.

Dimension drawing
Dimension drawing
MGB: impact test
MGB: mounting door on right, without escape release
MGB: mounting door on left, with escape release
MGB: mounting door on left, without escape release
MGB: in use
MGB: deactivating guard lock monitoring
MGB: pushbutton lens replacement
MGB: activating release monitoring
MGB: activating guard lock monitoring

Dimensional drawings

Dimensional drawings

Technical data

Approvals

TUEV Süd München_M6A 040393 0042 Rev. 00c_UL_us_E155795_3/9ProfiNET_Z10436_Version2024EAC_RU C-DE.HX37.B.14157/20DGUV_LB.520.38/09260/I_

Escape release MGB-E-A2-106051 (Order no. 106051)

Escape release MGB-E-A2-106051  (Order no. 106051)

Mechanical values and environment

Installation orientation any
Mechanical life 1 x 10⁶
Ambient temperature -30 ... +55 °C
Material
Housing Die-cast zinc/stainless steel, powder-coated

Miscellaneous

Product version number V2.0.0
Additional feature with mounting plate

Handle modules MGB-H-AA1A6-L-111839 (Order no. 111839)

Handle modules MGB-H-AA1A6-L-111839  (Order no. 111839)

Mechanical values and environment

Installation orientation Door hinge DIN left
Degree of protection IP65
Ambient temperature -20 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Miscellaneous

Product version number V3.0.0
Additional feature with mounting plate and automatic lockout mechanism

Locking modules MGB-L2CB-PN-L-106224 (Order no. 106224)

Locking modules MGB-L2CB-PN-L-106224  (Order no. 106224)

Workspace

Secured switch-off distance sar
Door position max. 65 mm

Operating and display elements

Occupancy diagram
B2
L2
C3
ItemColorExtrasSwitching elementSlide-in labelNote slide-in labelVersionNumberDesignation1LED
1white1NOIlluminated pushbutton
11RedCover for indicators
12white1NOIlluminated pushbutton
13Code 2 of 3Entsichert / Unsecured ; Sonderfunktion / Special function ; S-Bereich Gesichert / S-Zone SecuredOperating mode selector
2white1NOIlluminated pushbutton
3white1NOIlluminated pushbutton
4white1NOIlluminated pushbutton
5white1NOIlluminated pushbutton
6white1NOIlluminated pushbutton
72 PDEmergency stop
8white1NOIlluminated pushbutton

Electrical connection values

Connecting cable
Ethernet Profinet I/O cable, at least cat. 5e
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
maximum feed-in current in the connection block
X1, X2 max. 4000 mA
Safety class III
Current consumption max. 500 mA
Transponder coding Multicode
Degree of contamination (external, according to EN 60947-1) 3
Power supply X1
Fuse
external min. 1 A slow blow
Operating voltage DC
L1 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... +10% (For looping through for connected devices)
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (For looping through for connected devices)

Mechanical values and environment

Connection type
Push-pull power (X1 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
for enabling switch Plug connector RC12 (X14)
Push-pull power (X2 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45 (X3 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45 (X4 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).)
Installation orientation Door hinge DIN left
Switching frequency 0.25 Hz
Mechanical life
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
1 x 10⁶
Response time
Bolt position max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Emergency stop / machine stop max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Enabling switch max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Guard locking max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Operating mode selector max. 220 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Door position max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP54
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel
Locking force FZh 2000 N
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Enabling switch evaluation
Category 4
Performance Level PL e
PFHD 4.1 x 10-8

Miscellaneous

Slide-in label
NumberLabelingNote
Schutztür Öffnen
Anlage Start
Safety Gate Open
Line Start
Kühlwasser ein
S-Zone Secured
Cooling Water Extraction On
Anlage Stopp
Cooling Water Extraction Off
S-Zone Reset
Line Stop
S-Bereich Gesichert
S-Bereich Quittieren
Kühlwasser aus
Product version number V3.30.10

Interface

Bus data protocol Profinet (IEC 61158 type 10)
Safety data protocol Profisafe (IEC 61784-3-3)
Date interface
Ethernet

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 6,1 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 105284
Item designation MGB-L2HECB-PN-L-105284
Gross weight 7,827kg
Customs tariff number 85371098
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.