EUCHNER – More than safety.
EUCHNER – More than safety.

ZSA2B2CAS1 (Order no. 091580)

ZSA, 3-stage, AS-Interface

  • Housing G1
  • 3-stage function
  • Positively driven contacts
  • Dual-channel version
ZSA2B2CAS1 (Order no. 091580)

Description

AS-Interface inputs

D0, D1

Normally open contact

D2, D3

Normally open contact

3-stage function

Enabling function is active only in the second stage (center position, actuating point). Enabling is canceled when the pushbutton is released or pushed all the way down (panic function).

Dimension drawing
Dimension drawing
Connector assignment
Connector assignment
Travel diagram
Travel diagram

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples
View of connection side

Shift travel diagrams

Shift travel diagrams
closed, enabling
closed
open

Technical data

Approvals

CCC2020980305002418_CQC2009010305380679_2024EAC_RU C-DE.MO05.B.00972/20c_UL_us_E206093_4/2Asi Interface_56202_

Electrical connection values

ASI operating current max. 45 mA
ASI data in
according to AS-i Safety at Work D0, D1, D2, D3 (NO contact E1 on D0, D1 NO contact E2 on D2, D3)
AS-Interface protocol ASi-3
AS-Interface slave type ID-Code: B, EA-Code: 7
ASI voltage 22.5 ... 30 ... 31.6 V
Switching characteristics 3-stage enabling switch
Degree of contamination (external, according to EN 60947-1) 3

Mechanical values and environment

Connection type M12 plug connector, 4-pin
Number of NO contacts 2
Mechanical life
Position 1-2-1 0.1 x 10⁶
Position 1-2-3-1 0.1 x 10⁶
Switching principle Slow-action contact element
Degree of protection
Mating connector inserted and screwed tight IP65
Ambient temperature -5 ... +50 °C
Material Plastic

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Enabling switch
B10D 0.5 x 10⁶

Miscellaneous

in compliance with 60947-5-8

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 0,5 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 091580
Item designation ZSA2B2CAS1
Gross weight 0,183kg
Customs tariff number 85365019000
ECLASS 27-37-12-38 Agreement switch

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.