AS-Interface Safety at Work safety monitor with integrated Gateway GMOx
- Two AS-i masters
- Display and pushbuttons for diagnostics and adjustment
- Memory card for different programs
- Adjustable time-delay
- 16 OSSDs
Description
Gateway to Profibus
For connection to a Profibus DP as a slave and as a master for two AS-i buses according to specification 3.0. Detection of ground shunt, double addressing and EMC problems.
Rapid setup with the display without PC. Direct display of faults with plain-text messages. Comprehensive AS-i diagnostics integrated. AS-i configuration software is available.
OSSDs (Output Signal Switching Devices), AS-i outputs
- Two OSSDs with two redundant normally closed contacts each
- Two OSSDs with semiconductor outputs
- 12 additional safe AS-i outputs can be controlled
Inputs
- 4 inputs, freely selectable
Logic functions
Programmable with AsiMon software. All safety components can be programmed with different functions as inputs. The inputs can be linked with AND or OR gates or via logic functions such as FlipFlop, switch-on delay, OFF time or pulses.
Different programs can be stored on a memory card.
AS-Interface monitor
The monitor controls two AS-i circuits with up to 62 safe slaves and up to 16 outputs.
Display and pushbuttons
The display is used to operate the gateway functionality as well as the monitor at the same time. The diagnostics and maintenance functions are considerably expanded compared to the SFM monitors. They can also be launched on the display without a PC monitor.
Incorporated security functions allow the programmed functionality to be protected and monitored.
Power supply
Type N permits connection of several GMOx devices to the same power supply unit.
Important: A connection kit must be ordered for each safety monitor. See Accessories.
Dimensional drawings
Connection examples
Technical data
Approvals
Operating and display elements
Display | LCD AS-i slave address indication, error messages |
LED display | |
LED prj mode, configuration mode active | |
LED AS-i active AS-i operation normal | |
LED U AS-i voltage OK | |
LED prg enable automatic slave programming possible | |
LED AUX auxiliary power is present | |
LED PROFIBUS master detected | |
LED config error configuration error | |
4 x LEDs EDM / start state of the inputs for the external device monitoring circuits: LED off: open, LED on: closed | |
4 x LEDs, output circuits, state of the output circuits: LED off: open, LED on: closed | |
LED power, power supply ON |
Item | Color | Extras | Slide-in label | Version | Note slide-in label | Switching element | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
Pushbutton | 4 |
Electrical connection values
Power consumption | 9 W | ||||||||||||
Connection cross section | |||||||||||||
2x | 0.5 ... 1.5 mm² | ||||||||||||
2x | AWG 24 to 12 | ||||||||||||
Response delay | |||||||||||||
Safety circuit off | max. 40 ms | ||||||||||||
ASI operating current | max. 300 mA | ||||||||||||
AS-Interface protocol | ASi-3 | ||||||||||||
ASI voltage | 30 V | ||||||||||||
ASI cycle time | 150 μs 150 x (number of slaves + 2) | Outputs | |||||||||||
| |||||||||||||
Rated insulation voltage Ui | 500 V | Inputs | |||||||||||
| |||||||||||||
Switch-on delay | 10 s | ||||||||||||
Card slot | yes (Memory card to store the configuration data) |
Mechanical values and environment
Number of OSSDs | 16 (4 fed out) |
Number of masters | 2 |
Mounting type | TH 35 mounting rail (EN IEC 60715) |
Degree of protection | IP20 |
Ambient temperature | 0 ... +55 °C |
Material | |
Housing | Stainless steel |
permissible shock and vibration load | According to EN 61 131-2 |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Mission time | 20 y |
Category | 4 |
Performance Level | PL e |
PFHD | 5.36 x 10-9 |
SIL CL | 3 |
Miscellaneous
in compliance with | EN 61 000-6-2, EN 61 000-6-4, EN 62 061, IEC 61 508, EN ISO 13 849-1 |
Interface
Bus data protocol | PROFIBUS according to EN 50 170-3 |
Data rate | 9.6 ... 12000 kbit/s |
Date interface | Serial interface RS 232 |
Periphery | Decentralized peripheral equipment mapping of the AS-i slaves as I/O process data in the PROFIBUS; complete diagnostics and configuration via PROFIBUS DP master |
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Notice de montage Passerelle AS-i 3.0 PROFIBUS avec moniteur de sécurité intégré
Instrucciones de montaje Pasarela AS-i 3.0 PROFIBUS con monitor de seguridad integrado
Montageanweisung AS-i 3.0 PROFIBUS-Gateway mit integriertem Sicherheitsmonitor
Istruzioni per il montaggio Gateway AS-i 3.0 PROFIBUS con monitor di sicurezza integrato
Other Documents
Ordering data
Ordernumber | 103302 |
Item designation | GMOX-PR-22DN-C16 |
Gross weight | 0,959kg |
Customs tariff number | 85371098 |
ECLASS | 27-24-31-01 Configurable control component |