Transponder-coded safety switches with AS-Interface
Description
Transponder-coded safety switches are available both as a guard locking device, as well as an interlocking device of type 4. Unicode and multicode devices are available in both product groups. The interlocking devices feature a particularly compact read head design on the safety door. The guard locking device is a particularly robust solution with a very high locking force that meets PL e due to the integrated transponder technology.Features
- AS-Interface Safety at Work integrated
- Interlocking devices of type 4 with extremely compact read heads
- Metal guard locking devices with very high locking force
- With guard locking devices, both the door position and the locking position are monitored
![Transponder-coded safety switches with AS-Interface](https://assets2.euchner.de/files/95/54/729554.jpg)
You will find further information in our product catalog.
Product finder
Quick search
Degree of protection
Escape release
Connection
Guard locking
Products (20)
No results found
![CES-I-AS2A-M-C04-SC-120546](https://assets2.euchner.de/files/70/65/ast_737065_xs.png)
120546
CES-I-AS2A-M-C04-SC-120546
Safety switch CES-.-AS-C04 with AS-i connection, plug connector M8
CES-I-AS2A-M-C04-SC-120546
Safety switch CES-.-AS-C04 with AS-i connection, plug connector M8
- Very compact design with 3 active faces
- Integrated diagnostic LEDs
- Category 4 / PL e according to EN ISO 13849-1
- Plug connector M8, 3-pin
- Multicode
![CES-I-AS2A-U-C04-SC-120547](https://assets2.euchner.de/files/70/65/ast_737065_xs.png)
120547
CES-I-AS2A-U-C04-SC-120547
Safety switch CES-.-AS-C04 with AS-i connection, plug connector M8
CES-I-AS2A-U-C04-SC-120547
Safety switch CES-.-AS-C04 with AS-i connection, plug connector M8
- Very compact design with 3 active faces
- Integrated diagnostic LEDs
- Category 4 / PL e according to EN ISO 13849-1
- Plug connector M8, 3-pin
- Unicode
![CET3-AS-CRA-AB-50X-1-C2290-165486](https://assets2.euchner.de/files/57/88/ast_735788_xs.png)
165486
CET3-AS-CRA-AB-50X-1-C2290-165486
Safety switch CET-AS – with AS-i connection, closed-circuit current principle, with wire front release (bowden) 4 m
CET3-AS-CRA-AB-50X-1-C2290-165486
Safety switch CET-AS – with AS-i connection, closed-circuit current principle, with wire front release (bowden) 4 m
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Category 4 / PL e according to EN ISO 13849-1
- Unicode
- Wire front release (bowden), automatic return, rope length 4 m
- Approach direction A (delivery state)
![CET3-AS-CRA-AB-50X-SJ-AS1-111214](https://assets2.euchner.de/files/57/78/ast_735778_xs.png)
111214
CET3-AS-CRA-AB-50X-SJ-AS1-111214
Safety switch CET-AS – with AS-i connection, plug connector M12 (closed-circuit current principle)
CET3-AS-CRA-AB-50X-SJ-AS1-111214
Safety switch CET-AS – with AS-i connection, plug connector M12 (closed-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Category 4 / PL e according to EN ISO 13849-1
- Unicode
- Approach direction A (delivery state)
![CET3-AS-CRA-CB-50X-1-116514](https://assets2.euchner.de/files/57/78/ast_735778_xs.png)
116514
CET3-AS-CRA-CB-50X-1-116514
Safety switch CET-AS – with AS-i connection, plug connector M12 (closed-circuit current principle)
CET3-AS-CRA-CB-50X-1-116514
Safety switch CET-AS – with AS-i connection, plug connector M12 (closed-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Category 4 / PL e according to EN ISO 13849-1
- Multicode
- Approach direction A (delivery state)
![CET4-AS-CRA-AB-50X-SJ-AS1-113631](https://assets2.euchner.de/files/57/78/ast_735778_xs.png)
113631
CET4-AS-CRA-AB-50X-SJ-AS1-113631
Safety switch CET-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CET4-AS-CRA-AB-50X-SJ-AS1-113631
Safety switch CET-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Category 4 / PL e according to EN ISO 13849-1
- Unicode
- Approach direction A (delivery state)
![CET4-AS-CRA-CB-50X-1-116515](https://assets2.euchner.de/files/57/78/ast_735778_xs.png)
116515
CET4-AS-CRA-CB-50X-1-116515
Safety switch CET-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CET4-AS-CRA-CB-50X-1-116515
Safety switch CET-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Category 4 / PL e according to EN ISO 13849-1
- Multicode
- Approach direction A (delivery state)
![CET4-AS-CRB-AB-50X-1-120008](https://assets2.euchner.de/files/57/78/ast_735778_xs.png)
120008
CET4-AS-CRB-AB-50X-1-120008
Safety switch CET-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CET4-AS-CRB-AB-50X-1-120008
Safety switch CET-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Category 4 / PL e according to EN ISO 13849-1
- Unicode
- Approach direction B (delivery state)
![CKS-K-AS2A-U-C20-PC-123592](https://assets2.euchner.de/files/70/03/ast_737003_xs.png)
123592
CKS-K-AS2A-U-C20-PC-123592
Key adapter CKS-K-AS with AS-i connection
CKS-K-AS2A-U-C20-PC-123592
Key adapter CKS-K-AS with AS-i connection
- Key adapter with integrated CES read head
- Integrated diagnostic LEDs
- Category 4 / PL e according to EN ISO 13849-1
- Simple connection via AS-i
- High degree of protection IP67
![CTM-I2-AS2B-U-AZ-SJ-171319](https://assets2.euchner.de/files/83/14/ast_1278314_xs.png)
171319
CTM-I2-AS2B-U-AZ-SJ-171319
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTM-I2-AS2B-U-AZ-SJ-171319
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Guard locking only suitable for process protection: The safety outputs are switched on when the door is closed.
- Locking force up to 1000 N
- Up to category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Auxiliary release
- Unicode
![CTM-L2-AS1B-U-AZ-SJ-163976](https://assets2.euchner.de/files/83/14/ast_1278314_xs.png)
163976
CTM-L2-AS1B-U-AZ-SJ-163976
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTM-L2-AS1B-U-AZ-SJ-163976
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Locking force up to 1000 N
- Up to category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Auxiliary release
- Unicode
![CTM-L2-AS1B-U-AZ-SJ-163977](https://assets2.euchner.de/files/83/14/ast_1278314_xs.png)
163977
CTM-L2-AS1B-U-AZ-SJ-163977
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTM-L2-AS1B-U-AZ-SJ-163977
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Locking force up to 1000 N
- Up to category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Auxiliary release
- Unicode
![CTM-L2-AS1B-U-ZZ-SJ-P-163972](https://assets2.euchner.de/files/56/82/ast_1315682_xs.png)
163972
CTM-L2-AS1B-U-ZZ-SJ-P-163972
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTM-L2-AS1B-U-ZZ-SJ-P-163972
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Locking force up to 1000 N
- Up to category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Unicode
- Hygienic version
![CTM-L2-AS1B-U-ZZ-SJ-P-163974](https://assets2.euchner.de/files/56/82/ast_1315682_xs.png)
163974
CTM-L2-AS1B-U-ZZ-SJ-P-163974
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTM-L2-AS1B-U-ZZ-SJ-P-163974
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Locking force up to 1000 N
- Up to category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Unicode
- Hygienic version
![CTP-I2-AS2B-U-HA-AZC-SJ-166889](https://assets2.euchner.de/files/58/40/ast_735840_xs.png)
166889
CTP-I2-AS2B-U-HA-AZC-SJ-166889
Safety switch CTP-I2-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTP-I2-AS2B-U-HA-AZC-SJ-166889
Safety switch CTP-I2-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 3,900 N
- Category 4 / PL e according to EN ISO 13849-1
- Unicode
- Approach directions A, B and C (delivery state)
![CTP-L1-AS1B-M-HA-AZ-SJ-126645](https://assets2.euchner.de/files/58/40/ast_735840_xs.png)
126645
CTP-L1-AS1B-M-HA-AZ-SJ-126645
Safety switch CTP-L1-AS – with AS-i connection, plug connector M12 (closed-circuit current principle)
CTP-L1-AS1B-M-HA-AZ-SJ-126645
Safety switch CTP-L1-AS – with AS-i connection, plug connector M12 (closed-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 3,900 N
- Category 4 / PL e according to EN ISO 13849-1
- Multicode
- Approach directions A, B and C (delivery state)
![CTP-L1-AS1B-U-HA-AE-SJ-126644](https://assets2.euchner.de/files/58/98/ast_735898_xs.png)
126644
CTP-L1-AS1B-U-HA-AE-SJ-126644
Safety switch CTP-L1-AS – with AS-i connection, plug connector M12, with escape release (closed-circuit current principle)
CTP-L1-AS1B-U-HA-AE-SJ-126644
Safety switch CTP-L1-AS – with AS-i connection, plug connector M12, with escape release (closed-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 3,900 N
- Category 4 / PL e according to EN ISO 13849-1
- Unicode
- With escape release
- Approach directions A, B and C (delivery state)
![CTP-L1-AS1B-U-HA-AZ-SJ-124987](https://assets2.euchner.de/files/58/40/ast_735840_xs.png)
124987
CTP-L1-AS1B-U-HA-AZ-SJ-124987
Safety switch CTP-L1-AS – with AS-i connection, plug connector M12 (closed-circuit current principle)
CTP-L1-AS1B-U-HA-AZ-SJ-124987
Safety switch CTP-L1-AS – with AS-i connection, plug connector M12 (closed-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 3,900 N
- Category 4 / PL e according to EN ISO 13849-1
- Unicode
- Approach directions A, B and C (delivery state)
![CTP-L2-AS1B-M-HA-AZ-SJ-126646](https://assets2.euchner.de/files/58/40/ast_735840_xs.png)
126646
CTP-L2-AS1B-M-HA-AZ-SJ-126646
Safety switch CTP-L2-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTP-L2-AS1B-M-HA-AZ-SJ-126646
Safety switch CTP-L2-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 3,900 N
- Category 4 / PL e according to EN ISO 13849-1
- Multicode
- Approach directions A, B and C (delivery state)
![CTP-L2-AS1B-U-HA-AZ-SJ-124988](https://assets2.euchner.de/files/58/40/ast_735840_xs.png)
124988
CTP-L2-AS1B-U-HA-AZ-SJ-124988
Safety switch CTP-L2-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTP-L2-AS1B-U-HA-AZ-SJ-124988
Safety switch CTP-L2-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 3,900 N
- Category 4 / PL e according to EN ISO 13849-1
- Unicode
- Approach directions A, B and C (delivery state)