CES-AZ-AES-01B (Order no. 104770)

Evaluation unit CES-AZ-AES-01B (for 1 read head)

  • 1 read head can be connected
  • 2 safety outputs (relay contacts with 2 internally connected NO contacts per output)
  • Start button and feedback loop can be connected
  • Unicode
  • Plug-in connection terminals
  • Category 4 / PL e according to EN ISO 13849-1
CES-AZ-AES-01B (Order no. 104770)

Description

Unicode evaluation

Each actuator is highly coded (unicode). The evaluation unit detects only actuators that have been taught-in. Additional actuators can be taught-in.

Only the last actuator taught-in is detected.

New actuators are taught-in by fitting a jumper.

Guard lock monitoring

Evaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. You will find suitable read heads in the accessories

Category according to EN ISO 13849-1

Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for:

  • Category 4 / PL e according to EN ISO 13849-1

Each safety path is independently safe.

LED indicator

STATE

Status LED

DIA

Diagnostics LED

OUT

Safety output status

Additional connections

TST

Input for self-test

O1

Monitoring output (semiconductor)

DIA

Diagnostic output

Y1, Y2

Feedback loop

J

Teach-in input

S

Start button connection (monitoring of the falling edge)

Important: The plug-in connection terminals are not included and must be ordered separately.

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1Suitable for 35 mm mounting rail according to EN 60715

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20CCC2024010303657879_SafetyModule_CESc_UL_us_E155795_3/1DGUV_ET 20018_ET 20019

Workspace

Repeat accuracy R
according to EN 60947-5-2 max. 10 %

Operating and display elements

LED display
Diagnostics LED
Status LED
Safety contacts status

Electrical connection values

Fuse
external (operating voltage UB) 0.25 ... 8 A
Connection cross section
Plug-in screw / spring terminals 0.25 ... 2.5 mm²
Operating voltage DC
UB 21 ... 24 ... 27 V DC regulated, residual ripple<5%
EMC protection requirements Acc. to EN 60947-5-3
Current consumption
(with relay energized) 150 mA (without taking into account the load currents at the monitoring outputs)
Current via feedback loop 5 ... 8 ... 10 mA
Degree of contamination (external, according to EN 60947-1) 2
permissible resistance in feedback loop max. 600 Ω
Inputs: start button S, test input TST
Input voltage
HIGH 15 ... UB V DC
LOW 0 ... 2 V DC
Input current
HIGH 5 ... 8 ... 10 mA
Monitoring outputs: diagnostics DIA, door monitoring output O1
Output type Semiconductor output, p-switching, short circuit-proof
Output voltage 0.8 x UB ... UB V DC
Switching current max. 20 mA
Safety contacts 13/14, 23/24
Fuse
external (safety circuit) according to EN 60269-1 6 AgG or 6 A circuit breaker (characteristic B or C)
Output type Relay contacts, floating
rated conditional short-circuit current 100 A
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 4 kV
Discrepancy time
(between the operating points of both relays) max. 25 ms
Utilization category
DC-12 30 V 6 A
AC-15 230 V 2 A
AC-12 60 V 0.3 A
AC-12 30 V 6 A
DC-13 24 V 3 A
DC-12 60 V 0.3 A
Switching load
according to c UL us Class 2 max. 30 V AC / Class 2 max. 60V DC
Switching current
at switching voltage AC 5 ... 230 V 10 ... 2000 mA
at switching voltage AC/DC 21 ... 60 V 1 ... 300 mA
at switching voltage AC/DC 5 ... 30 V 10 ... 6000 mA

Mechanical values and environment

Connection type plug-in connection terminals, coded (Terminals not included)
Number of read heads 1 read head can be connected
Ready delay 10 ... 12 s (After the operating voltage is switched on, the relay outputs are switched off and the door monitoring output is set to LOW level during the ready delay. For visual indication of the delay, the green STATE LED flashes at a frequency of approx. 15 Hz.)
Switching frequency max. 0.25 Hz
Atmospheric humidity
not condensing max. 80 % rH
Mounting distance
between evaluation units min. 10 mm
Mounting type TH 35 mounting rail (EN IEC 60715)
Response time
after change in the actuation status max. 210 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum OFF time for the safety outputs following removal of the actuator. In case of EMC interference in excess of the requirements in accordance with EN 60947-5-3, the OFF time can increase to max. 250 ms. After brief actuation
Start button actuating duration (for Manual Start operating mode) min. 250 ms
Start button response delay (for Manual start operating mode) 200 ... 300 ms
Degree of protection IP20
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Dwell time min. 3 s (The dwell time is the time that the actuator must be outside the actuating range.)
Material
Housing Plastic PA6.6
Safety contacts 13/14, 23/24
Number of safety contacts 2 Relay with internally monitored contacts
Mechanical life
Operating cycles (relay) 10 x 10⁶

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Number of switching cycles
≤ 0.1 A at 24 V DC max. 760000 1/y
≤ 1 A at 24 V DC max. 153000 1/y
≤ 3 A at 24 V DC max. 34600 1/y
Diagnostic Coverage (DC) 99 %
Mission time 20 y (This value is dependent on the number of switching cycles and the switching current.)
Monitoring of the guard position
Category 4 (This value is dependent on the number of switching cycles and the switching current.)
Performance Level PL e (This value is dependent on the number of switching cycles and the switching current.)
PFHD 1.9 x 10-8 (This value is dependent on the number of switching cycles and the switching current.)
Safety contacts 13/14, 23/24
Number of switching cycles
≤ 0.1 A at 24 V DC max. 760000 1/y
≤ 3 A at 24 V DC max. 34600 1/y
≤ 1 A at 24 V DC max. 153000 1/y

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measure.

In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V

Mounting distance
between read heads min. 50 mm

In combination with read head CES-A-LMN-SC and actuator CES-A-BDA-18-156935

Actuator distance s
Minimum distance for side approach direction min. 3 mm
Switch-on distance
with center offset m=0 9 mm (These values apply to surface installation of the read head and the actuator.)
Secured switch-off distance sar max. 21 mm
Secured switching distance sao
with center offset m=0 min. 6 mm (These values apply to surface installation of the read head and the actuator.)
Switching hysteresis
with center offset m=0 0.5 ... 1 mm (These values apply to surface installation of the read head and the actuator.)

In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-18-156935

Actuator distance s
Minimum distance for side approach direction min. 5 mm
Switch-on distance
with center offset m=0 16 mm (These values apply to surface installation of the read head and the actuator.)
Secured switch-off distance sar max. 32 mm
Secured switching distance sao
with center offset m=0 min. 10 mm (These values apply to surface installation of the read head and the actuator.)
Switching hysteresis
with center offset m=0 0.5 ... 1.4 mm (These values apply to surface installation of the read head and the actuator.)

In combination with read head CES-A-LMN-SC and actuator CES-A-BDA-20

Switch-on distance
with center offset m=0 9 mm A distance of s = 4 mm must be maintained for a side approach direction. (This value applies to surface installation of the read head in metal and non-metallic installation of the actuator.)
Secured switch-off distance sar
with center offset m=0 max. 26 mm (This value applies to surface installation of the read head in metal and non-metallic installation of the actuator.)
Secured switching distance sao
with center offset m=0 min. 6 mm (This value applies to surface installation of the read head in metal and non-metallic installation of the actuator.)
Switching hysteresis
with center offset m=0 1 ... 1.8 mm (These values apply to surface installation of the read head in metal and non-metallic installation of the actuator.)

In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294 and actuator CES-A-BBN-106600

Switch-on distance
in z direction (with center offset x,y=0), in y direction (with center offset x,z=0) 15 mm (These values apply to surface installation of the read head and the actuator.)
Secured switch-off distance sar
in y direction max. 100 mm
in x or z direction max. 50 mm
Secured switching distance sao
in z direction (with center offset x,y=0), in y direction (with center offset x,z=0) min. 10 mm (These values apply to surface installation of the read head and the actuator.)
Switching hysteresis 1 ... 4 mm (These values apply to surface installation of the read head and the actuator.)

In combination with read head CES-A-LQA-SC and actuator CES-A-BQA

Switch-on distance
for vertical approach direction (center offset m=0) 23 mm (These values apply to surface installation of the read head and the actuator.)
for side approach direction (distance in x direction 10 mm) +/- 28 mm (These values apply to surface installation of the read head and the actuator.)
Secured switch-off distance sar max. 60 mm
Secured switching distance sao
for vertical approach direction (center offset m=0) min. 16 mm (These values apply to surface installation of the read head and the actuator.)
for side approach direction (distance in x direction 10 mm) min. +/- 24 mm (These values apply to surface installation of the read head and the actuator.)
Switching hysteresis
for side approach direction (distance in x direction 10 mm) 1 ... 1.3 mm (These values apply to surface installation of the read head and the actuator.)
for vertical approach direction (center offset m=0) 2 ... 3 mm (These values apply to surface installation of the read head and the actuator.)

In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294 and actuator CES-A-BDN-06-104730

Switch-on distance
in z direction (with center offset x,y=0), in y direction (with center offset x,z=0) 19 mm (These values apply to surface installation of the read head and the actuator.)
Secured switch-off distance sar
in x or z direction max. 50 mm
in y direction max. 100 mm
Secured switching distance sao
in z direction (with center offset x,y=0), in y direction (with center offset x,z=0) min. 14 mm (These values apply to surface installation of the read head and the actuator.)
Switching hysteresis 4 mm (These values apply to surface installation of the read head and the actuator.)

In combination with read head CES-A-LSP-05V-104966 and actuator CES-A-BSP-104970

Switch-on distance
with center offset m=0 20 mm (These values apply to installation of the read head and the actuator in an aluminum profile 45 x 45 mm.)
Secured switch-off distance sar max. 45 mm
Secured switching distance sao
with center offset m=0 min. 10 mm (These values apply to installation of the read head and the actuator in an aluminum profile 45 x 45 mm.)
Switching hysteresis 1 ... 4 mm (These values apply to installation of the read head and the actuator in an aluminum profile 45 x 45 mm.)

In combination with read head CES-A-LMN-SC and actuator CES-A-BBA-071840

Switch-on distance
with center offset m=0 8 mm A distance of s = 3 mm must be maintained for a side approach direction. (This value applies to surface installation of the read head in metal and non-metallic installation of the actuator.)
Secured switch-off distance sar
with center offset m=0 max. 25 mm (This value applies to surface installation of the read head in metal and non-metallic installation of the actuator.)
Secured switching distance sao
with center offset m=0 min. 5 mm (This value applies to surface installation of the read head in metal and non-metallic installation of the actuator.)
Switching hysteresis
with center offset m=0 1 ... 1.8 mm (These values apply to surface installation of the read head in metal and non-metallic installation of the actuator.)

In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BBA-071840, CES-A-BCA

Actuator distance s
Minimum distance for side approach direction min. 3 mm
Switch-on distance
with center offset m=0 15 mm (These values apply to surface installation of the read head and the actuator.)
Secured switch-off distance sar max. 26 mm
Secured switching distance sao
with center offset m=0 min. 10 mm (These values apply to surface installation of the read head and the actuator.)
Switching hysteresis 0.5 ... 2 mm (These values apply to surface installation of the read head and the actuator.)

In combination with read head CES-A-LMN-SC

Mounting distance
between read heads min. 20 mm

In combination with read head CES-A-LQA-SC

Mounting distance
between read heads min. 80 mm

In combination with read head CES-A-LQA-SC and actuator CES-A-BBA-071840, CES-A-BCA

Switch-on distance
for side approach direction (distance in x direction 8 mm) +/- 22 mm (These values apply to surface installation of the read head and the actuator.)
for vertical approach direction (center offset m=0) 15 mm (These values apply to surface installation of the read head and the actuator.)
Secured switch-off distance sar max. 47 mm
Secured switching distance sao
for vertical approach direction (center offset m=0) min. 10 mm (These values apply to surface installation of the read head and the actuator.)
for side approach direction (distance in x direction 8 mm) min. +/- 18 mm (These values apply to surface installation of the read head and the actuator.)
Switching hysteresis
for side approach direction (distance in x direction 8 mm) 1 ... 1.8 mm (These values apply to surface installation of the read head and the actuator.)
for vertical approach direction (center offset m=0) 2 ... 3 mm (These values apply to surface installation of the read head and the actuator.)

In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-20

Actuator distance s
Minimum distance for side approach direction min. 4 mm (on mounting in non-metallic environment)
Switch-on distance
with center offset m=0 16 mm (on mounting in non-metallic environment)
Secured switch-off distance sar max. 33 mm
Secured switching distance sao
with center offset m=0 min. 11 mm (on mounting in non-metallic environment)
Switching hysteresis 0.5 ... 2 mm (on mounting in non-metallic environment)

In combination with read head CES-A-LMN-SC and actuator CES-A-BMB

Actuator distance s
Minimum distance min. 1.2 mm
Switch-on distance
with center offset m=0 5 mm (These values apply to surface installation of the read head in steel.)
Secured switch-off distance sar max. 10 mm
Secured switching distance sao
with center offset m=0 min. 3.5 mm (These values apply to surface installation of the read head in steel.)
Switching hysteresis 0.1 ... 0.3 mm (These values apply to surface installation of the read head in steel.)

In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294

Mounting distance
between read heads min. 160 mm

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 8,3 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 104770
Item designation CES-AZ-AES-01B
Gross weight 0,231kg
European Article Number (EAN) 4047048005648
Customs tariff number 85364110
ECLASS 27-27-24-03 Safety-related transponder switch

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.