Field evaluation unit CES-FD-AS2A with ASi connection
- Connection of a CES read head or CKS Electronic-Key adapter via M8 plug connector(s)
- Evaluation of transponder data
- Integrated ASi connection, permanently connected PUR cable
- Unicode
- Highest safety at category 4 / PL e according to EN ISO 13849-1
Description
Unicode evaluation
Each actuator/key contains a transponder with a high coding level in accordance with EN ISO 14119. The evaluation unit only recognizes taught-in actuators. Further actuators can be taught-in. Only the last actuator learned is recognized.
AS-Interface
ASi-3 protocol
PUR connection cable, connecting cable with flying lead, 2-wire
AS-Interface inputs
D0, D1, D2, D3 Detection of actuators/keys
Evaluation takes place via a safety monitor
LED function display
The STATE LED indicates the status of the switch
The DIA LED indicates whether an error has been detected in the switch
Dimensional drawings
1 | LED status indication |
2 | Cable end sleeve |
Connection examples
Technical data
Electrical connection values
ASI data in | |
according to AS-Interface Safety ta Work | D0 - D3 (Key / actuator detection) |
ASI slave type | |
min. | EA code: 0 |
max. | ID code: B |
ASI voltage | |
DC | 19 ... 31.6 V |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Turn-on time | |
Safety outputs | max. 300 ms |
Risk time according to EN 60947-5-3 | max. 260 ms |
Safety class | III |
Current consumption | |
total | max. 50 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Mechanical values and environment
Connection type | |
Evaluation | Connection cable, connecting cable PUR with plug connector(s) M8X1 3-pin |
Read head | PUR connection cable, connecting cable with flying lead, 2-core |
Ready delay | 0.5 s |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65/IP67 |
Cable ambient temperature (dynamic) | -5 ... +65 °C |
Cable ambient temperature (static) | -20 ... +55 °C |
Material | |
Housing | Plastic, PBT |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | ||
---|---|---|---|---|---|---|
Monitoring of the guard position | Lesekopf CES-A-LMN | PL e | - | 4.5x10-9 | 4 | 20 y |
Safe key detection | Lesekopf CKS-A-L.. | PL e | - | 4.5x10-9 | 3 | 20 y |
Miscellaneous
The following applies to the approval according to UL | Mode only with UL Class 2 power supply |
Accessories
CKS-A-L1B-SC-113130
- Key adapter with integrated CES read head
- Simple connection via plug connector M8
- Front cover: red
- High degree of protection IP67
- LED indicator
CKS-A-L1B-SC-158081
- Key adapter with integrated CES read head
- Simple connection via plug connector M8
- Front cover: black
- High degree of protection IP67
- LED indicator
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Other Documents
Ordering data
Ordernumber | 172238 |
Item designation | CES-FD-AS2A-U-01-U002-172238 |
Gross weight | 0,07kg |
Customs tariff number | 85365019000 |
ECLASS | 27-27-24-03 Safety-related transponder switch |