HomeProductsTransponder-coded read heads with external evaluationField evaluation unit CES-FDCES-FD-AP-U-01-USI-166446
Field evaluation unit CES-FD-AP-…
- connection of a CES/CKS read head
- Evaluation of signals in the field
- EUCHNER AP interface
- Suitable for separate operation (no series connection)
- Unicode
- Direct connection to IP67 field modules (e.g. ET200pro)
- Connecting cables PUR, with plug connector: - M8 angled / 3-pin (read head connection) - M12 straight / 5-pin (AP interface)

Description
Short circuit monitoring
The switch generates its own clock signal on the output lines FO1A/FO1B. Pay attention to this aspect when connecting to control systems and relays.
Category according to EN ISO 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4 / PL e according to EN ISO 13849-1
Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must always be evaluated.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
Connection for control system


Dimensional drawings

1 | LED status indication |
2 | Coding lug |
Connection examples

Technical data
Approvals


Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | <= 10 |
Electrical connection values
Fuse | |
external (operating voltage) | 0.25 ... 8 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Operating voltage DC | |
UB (PELV, see operating instructions) (reverse polarity protected, regulated, residual ripple<5%) | 24 V DC -15% ... +15% (The device tolerates voltage interruptions in the operating voltage, e.g. test pulses, of up to 5 ms. These voltage interruptions are also output on the safety outputs.) |
Turn-on time | |
Safety outputs | max. 400 ms |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Risk time according to EN 60947-5-3 | max. 260 ms |
Safety class | III |
Current consumption | max. 45 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety outputs FO1A / FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
HIGH U(FO1A) / U(FO1B) | UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
rated conditional short-circuit current | 100 A |
Discrepancy time | max. 10 ms |
Utilization category | |
DC-13 | 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Off-state current Ir | max. 0.25 mA |
Switching current | |
per safety output | 1 ... 150 mA |
Test pulse duration | max. 0.3 ms (Applies to a load with C<= 30 nF and R<= 20 kohm) |
Test pulse interval | min. 100 ms |
Mechanical values and environment
Connection type | Connecting cable PUR with plug connector M12, 5-pin; pin 5 not used |
Tightening torque | max. 1 Nm |
Ready delay | 1 s |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65/IP67 |
Cable ambient temperature (dynamic) | -5 ... +65 °C |
Cable ambient temperature (static) | -20 ... +65 °C |
Material | |
Housing | Plastic, PBT |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Mission time | 20 y |
Monitoring of the guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.5 x 10-9 |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures |
In combination with read head CES-A-LMN-SC and actuator CES-A-BMB
Switch-on distance | 5 mm (With read head CES-A-LMN-SC and actuator CES-A-BMB) |
Secured switch-off distance sar | max. 10 mm (With read head CES-A-LMN-SC and actuator CES-A-BMB) |
Secured switching distance sao | min. 3.4 mm (With read head CES-A-LMN-SC and actuator CES-A-BMB) |
Switching hysteresis | 0.05 ... 0.2 mm (With read head CES-A-LMN-SC and actuator CES-A-BMB) |
Accessories
Connection material
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
Other Documents
Approvals and certificates
c UL us
Doc. no.
Version
Language
Size

c UL us
Doc. no.
Version
Language
Size
0,3 MB
Sales documents
Flexibel sicher - Transpondercodierte Sicherheitssysteme CES
Doc. no.
Version
Language
Size

Flexibel sicher - Transpondercodierte Sicherheitssysteme CES
Doc. no.
119922
Version
06-06/22
Language
Size
8,4 MB
UQS document
Bescheinigung
Doc. no.
Version
Language
Size

Bescheinigung
Doc. no.
ECO2116784
Version
Language
Size
0,2 MB
Ordering data
Ordernumber | 166446 |
Item designation | CES-FD-AP-U-01-USI-166446 |
Gross weight | 0,85kg |
Customs tariff number | 85365019 |
ECLASS | 27-27-24-03 Safety-related transponder switch |