Safety switch CTM-AS
Benefits for you
- Integrated AS-i connection
- Robust housing with degree of protection IP67/IP69/IP69K
- Compact design
- Comprehensive and detailed diagnostics option.
Design and functionality
The CTM-AS can be operated directly on the AS-i bus and provides the control system with both the door position and information about the locking position.Information about a possible malfunction in the switch can also be diagnosed directly in the control system.
Operation on all known AS-i safety monitors in the proven manner is a matter of course.
![Safety switch CTM-AS](https://assets2.euchner.de/files/34/96/ast_2623496.png)
Products (5)
No results found
![CTM-I2-AS2B-U-AZ-SJ-171319](https://assets2.euchner.de/files/83/14/ast_1278314_xs.png)
171319
CTM-I2-AS2B-U-AZ-SJ-171319
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTM-I2-AS2B-U-AZ-SJ-171319
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Guard locking only suitable for process protection: The safety outputs are switched on when the door is closed.
- Locking force up to 1000 N
- Up to category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Auxiliary release
- Unicode
![CTM-L2-AS1B-U-AZ-SJ-163976](https://assets2.euchner.de/files/83/14/ast_1278314_xs.png)
163976
CTM-L2-AS1B-U-AZ-SJ-163976
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTM-L2-AS1B-U-AZ-SJ-163976
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Locking force up to 1000 N
- Up to category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Auxiliary release
- Unicode
![CTM-L2-AS1B-U-AZ-SJ-163977](https://assets2.euchner.de/files/83/14/ast_1278314_xs.png)
163977
CTM-L2-AS1B-U-AZ-SJ-163977
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTM-L2-AS1B-U-AZ-SJ-163977
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Locking force up to 1000 N
- Up to category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Auxiliary release
- Unicode
![CTM-L2-AS1B-U-ZZ-SJ-P-163972](https://assets2.euchner.de/files/56/82/ast_1315682_xs.png)
163972
CTM-L2-AS1B-U-ZZ-SJ-P-163972
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTM-L2-AS1B-U-ZZ-SJ-P-163972
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Locking force up to 1000 N
- Up to category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Unicode
- Hygienic version
![CTM-L2-AS1B-U-ZZ-SJ-P-163974](https://assets2.euchner.de/files/56/82/ast_1315682_xs.png)
163974
CTM-L2-AS1B-U-ZZ-SJ-P-163974
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
CTM-L2-AS1B-U-ZZ-SJ-P-163974
Safety switch CTM-AS – with AS-i connection, plug connector M12 (open-circuit current principle)
- Guard locking only suitable for process protection: The safety outputs are switched on when guard locking is active.
- Locking force up to 1000 N
- Up to category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 35/30/15 N
- Unicode
- Hygienic version