Transponder-coded safety switch CTM-LBI-BP, M12
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuation/extension/retention force: 20/18/5 N
- Plug connector M12, 8-pin
- Auxiliary release
- Multicode
![CTM-LBI-BP-M-AZ-SA-166090 (Order no. 166090)](https://assets2.euchner.de/files/71/68/ast_737168_xl.png)
Description
Multicode evaluation
Every suitable actuator is detected by the switch.
Guard locking type
CTM‑LBI | Guard locking operated by means of input signal. |
This type of guard locking has a function to prevent
- persons from unintentionally locking themselves inside if the safety door is open in case of a power failure or if the machine is switched off.
- the deactivation of the activated guard locking in case of a power failure.
Connector assignment
![Dimension drawing](https://assets2.euchner.de/files/29/57/ast_642957_m.png)
![Wiring diagram](https://assets2.euchner.de/files/76/69/ast_1217669_m.png)
Dimensional drawings
![Dimensional drawings](https://assets2.euchner.de/files/29/57/ast_642957.png)
1 | LEDs |
2 | Active read head face |
3 | Auxiliary release |
Connection examples
![Connection examples](https://assets2.euchner.de/files/76/69/ast_1217669.png)
Technical data
Approvals
![EAC_RU C-DE.MO05.B.00971/20](https://assets2.euchner.de/files/06/97/ast_630697_m.png)
![c_UL_us_E155795_3/11](https://assets2.euchner.de/files/08/52/ast_630852_m.png)
![FCC_2AJ58-07_](https://assets2.euchner.de/files/08/42/ast_630842_m.png)
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | 10 % |
Electrical connection values
Fuse | |
external (operating voltage UB) | 0.7 ... 8 A |
Power consumption | |
at max. switching frequency | 3 W |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
Discrepancy time | |
both safety outputs | max. 10 ms Acc. to EN 60947-5-3 |
Turn-on time | max. 400 ms |
Solenoid duty cycle | 100 % |
Off-state current Ir | max. 0.25 mA |
Risk time according to EN 60947-5-3 | max. 200 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 10 ms |
Switching load | DC 24V, UL Class 2 (alternatively, see operating instructions) |
Safety class | |
EN IEC 61140 | III |
Test pulse duration | max. 0.3 ms |
Test pulse interval | 100 ms |
Degree of contamination (external, according to EN 60947-1) | |
Industry | 3 |
Solenoid IMP | |
Input voltage | |
Guard locking active (closed) | 0 ... 5 V DC |
Guard locking not active (open) | 20.4 ... 26.4 V DC |
Current consumption | |
Guard locking not active (open) | 20 ... 50 mA |
Diagnostic output OI, monitoring output OD/C, guard lock monitoring output OL | |
Output type | p-switching, short circuit-proof |
Output voltage | 0.8xUB ... UB V DC |
Switching current | 1 ... 50 mA |
Safety outputs FO1A / FO1B | |
Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
HIGH U(FO1A) / U(FO1B) | UB-1.5 ... UB V DC |
Discrepancy time | |
both safety outputs | max. 10 ms Acc. to EN 60947-5-3 |
Turn-on time | max. 400 ms |
Utilization category | |
DC-13 | 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads) |
Off-state current Ir | max. 0.25 mA |
Risk time according to EN 60947-5-3 | |
Single device | max. 200 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 10 ms |
Electrical switching frequency | max. 0.25 Hz |
Switching current | |
per safety output FO1A / FO1B | 1 ... 150 mA |
Test pulse duration | max. 0.3 ms (Applies to a load with C<= 30 nF and R<= 20 kohm) |
Test pulse interval | 100 ms |
Operating voltage UB | |
Operating voltage DC | |
UUB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV |
Current consumption | |
IUB at operating voltage UB = 24 V | max. 500 mA |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection type | Plug connector M12, 8-pin |
Extraction force | 18 N |
Ready delay | 5.5 s |
Actuating force | 20 N |
Installation orientation | any |
Switching frequency | max. 0.25 Hz |
Mechanical life | 1 x 10⁶ |
Overtravel | 2 mm |
Retention force | 5 N |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65/IP67 (screwed tight plug connector/mating component) |
Ambient temperature | |
at UB = 24 V DC | -20 ... +60 °C |
Material | |
Safety switch housing | Reinforced thermoplastic |
Seals | Fluorinated rubber (FKM) |
Locking force Fmax | 1300 N |
Locking force FZh | 1000 N |
Guard locking principle | BiState |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Control of guard locking | PL d | 2 | 1.03x10-7 | 3 | 20 y |
Monitoring of the guard position | PL e | 3 | 4.11x10-9 | 4 | 20 y |
Monitoring of guard locking | PL e | 3 | 4.11x10-9 | 4 | 20 y |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
Accessories
Actuator
Actuator for safety switch CTM
![A-B-A1-A1-161642](https://assets2.euchner.de/files/59/51/ast_735951_xs.png)
161642
A-B-A1-A1-161642
A-B-A1-A1-161642
- Flexible ball actuator
- Door radii from 150 mm
- Two M4x14 safety screws are included in the scope of delivery.
![A-B-A5-A1-168489](https://assets2.euchner.de/files/96/68/ast_2299668_xs.png)
168489
A-B-A5-A1-168489
A-B-A5-A1-168489
- Ball actuator supported on floating bearing
- With M5 threaded bushings
- Door radii from 150 mm
- Two M4x14 safety screws are included in the scope of delivery.
Connection material
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
![Doc. no. EDC2525461](https://assets2.euchner.de/files/92/28/ast_3159228_thumb.jpg)
EU-Konformitätserklärung
Doc. no.
EDC2525461
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
![Doc. no. EDC20001477](https://assets2.euchner.de/files/92/14/ast_3159214_thumb.jpg)
UKCA-Konformitätserklärung
Doc. no.
EDC20001477
Version
Language
Size
0,1 MB
Instructions
Operating Instructions Transponder-Coded Safety Switch with Guard Locking CTM-LBI-BP/BR Unicode/Multicode with Control of Guard Locking via Control Input IMP
Doc. no.
Version
Language
Size
![Doc. no. 2525462](https://assets2.euchner.de/files/84/25/ast_3208425_thumb.jpg)
Operating Instructions Transponder-Coded Safety Switch with Guard Locking CTM-LBI-BP/BR Unicode/Multicode with Control of Guard Locking via Control Input IMP
Doc. no.
2525462
Version
04/24
Language
Size
2,8 MB
![Doc. no. 2525462](https://assets2.euchner.de/files/84/26/ast_3208426_thumb.jpg)
Mode d’emploi Interrupteur de sécurité à codage par transpondeur avec interverrouillage CTM-LBI-BP/BR Uni-/multicode avec commande de l’interverrouillage via l’entrée de commande IMP
Doc. no.
2525462
Version
04/24
Language
Size
2,8 MB
![Doc. no. 2525462](https://assets2.euchner.de/files/84/27/ast_3208427_thumb.jpg)
Manual de instrucciones Interruptor de seguridad codificado por transponder con bloqueo CTM-LBI-BP/BR Unicode/Multicode con accionamiento del bloqueo a través de la entrada de control IMP
Doc. no.
2525462
Version
04/24
Language
Size
2,8 MB
![Doc. no. 2525462](https://assets2.euchner.de/files/78/63/ast_3207863_thumb.jpg)
Betriebsanleitung Transpondercodierter Sicherheitsschalter mit Zuhaltung CTM-LBI-BP/BR Uni-/Multicode mit Ansteuerung der Zuhaltung über den Steuereingang
Doc. no.
2525462
Version
04/24
Language
Size
2,6 MB
![Doc. no. 2525462](https://assets2.euchner.de/files/84/28/ast_3208428_thumb.jpg)
Návod k použití Bezpečnostní spínač s kódovaným transpondérem a jištěním ochranného krytu CTM-LBI-BP/BR Unicode/Multicode s ovládáním jištění ochranného krytu prostřednictvím řídicího vstupu IMP
Doc. no.
2525462
Version
04/24
Language
Size
3,2 MB
Other Documents
Approvals and certificates
FCC
Doc. no.
Version
Language
Size
![Doc. no.](https://assets2.euchner.de/files/36/35/ast_743635_thumb.jpg)
FCC
Doc. no.
Version
Language
Size
0,1 MB
ISED
Doc. no.
Version
Language
Size
![Doc. no.](https://assets2.euchner.de/files/39/40/ast_1163940_thumb.jpg)
ISED
Doc. no.
Version
Language
Size
1,2 MB
c UL us
Doc. no.
Version
Language
Size
![Doc. no.](https://assets2.euchner.de/files/05/73/ast_2960573_thumb.jpg)
c UL us
Doc. no.
Version
Language
Size
1,0 MB
Sales documents
Communication du futur – industrie 4.0
Doc. no.
Version
Language
Size
![Doc. no. 159044](https://assets2.euchner.de/files/93/41/ast_2899341_thumb.jpg)
Communication du futur – industrie 4.0
Doc. no.
159044
Version
08-03/23
Language
Size
4,7 MB
Future-proof Communication – Industry 4.0
Doc. no.
Version
Language
Size
![Doc. no. 159043](https://assets2.euchner.de/files/92/68/ast_2899268_thumb.jpg)
Future-proof Communication – Industry 4.0
Doc. no.
159043
Version
08-03/23
Language
Size
5,8 MB
La comunicación del futuro: la industria 4.0
Doc. no.
Version
Language
Size
![Doc. no. 159045](https://assets2.euchner.de/files/98/37/ast_2899837_thumb.jpg)
La comunicación del futuro: la industria 4.0
Doc. no.
159045
Version
08-03/23
Language
Size
5,8 MB
Zukunftsfähige Kommunikation – Industrie 4.0
Doc. no.
Version
Language
Size
![Doc. no. 159042](https://assets2.euchner.de/files/91/24/ast_2899124_thumb.jpg)
Zukunftsfähige Kommunikation – Industrie 4.0
Doc. no.
159042
Version
08-03/23
Language
Size
5,8 MB
小型ながら大 きなメリット - ガードロック付きトランスポンダ ー・コーデッド安全スイッチ CTM
Doc. no.
Version
Language
Size
![Doc. no. 166084](https://assets2.euchner.de/files/91/80/ast_1939180_thumb.jpg)
小型ながら大 きなメリット - ガードロック付きトランスポンダ ー・コーデッド安全スイッチ CTM
Doc. no.
166084
Version
03-07/21
Language
Size
4,7 MB
面向未来的通信 – 工业4.0
Doc. no.
Version
Language
Size
![Doc. no. 164814](https://assets2.euchner.de/files/02/80/ast_1630280_thumb.jpg)
面向未来的通信 – 工业4.0
Doc. no.
164814
Version
06-05/21
Language
Size
6,2 MB
UQS document
Bescheinigung
Doc. no.
Version
Language
Size
![Doc. no. ECO20001463](https://assets2.euchner.de/files/03/27/ast_2790327_thumb.jpg)
Bescheinigung
Doc. no.
ECO20001463
Version
Language
Size
0,2 MB
CAD data
Ordering data
Ordernumber | 166090 |
Item designation | CTM-LBI-BP-M-AZ-SA-166090 |
Gross weight | 0,26kg |
Customs tariff number | 85365019 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |