EUCHNER – More than safety.
EUCHNER – More than safety.

CTM-LBI-BR-U-ZZ-SA-P-161496 (Order no. 161496)

Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version

  • Series connection possible
  • Bistable guard locking
  • Category 4 / PL e according to EN ISO 13849-1
  • Actuation/extension/retention force: 35/30/15 N
  • Plug connector M12, 8-pin
  • Unicode
  • Hygienic version
CTM-LBI-BR-U-ZZ-SA-P-161496 (Order no. 161496)

Description

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.

Guard locking type

CTM‑LBI

Guard locking operated by means of input signal.

This type of guard locking has a function to prevent

  • persons from unintentionally locking themselves inside if the safety door is open in case of a power failure or if the machine is switched off.
  • the deactivation of the activated guard locking in case of a power failure.

series connection

Safety switches in the CTM-...-BR version can be integrated into a BR device chain. Further information on series connection can be found in the operating instructions for the device.

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1FI1BEnable input, channel 2WH
2UBOperating voltage 24 V DCBN
3FO1ASafety output, channel 1GN
4FO1BSafety output, channel 2YE
5OD/CDoor monitoring output/communicationGY
6FI1AEnable input, channel 1PK
70VUBOperating voltage, 0 VBU
8IMPControl input of guard locking solenoidRD
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1LEDs
2Active read head face

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/11FCC_2AJ58-07_ECOLAB_CTM_

Workspace

Repeat accuracy R
according to EN 60947-5-2 10 %

Electrical connection values

Fuse
external (operating voltage UB) 0.7 ... 8 A
Power consumption
at max. switching frequency 3 W
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 0.5 kV
Discrepancy time
both safety outputs max. 10 ms Acc. to EN 60947-5-3
Turn-on time max. 400 ms
Solenoid duty cycle 100 %
Off-state current Ir max. 0.25 mA
Risk time according to EN 60947-5-3 max. 200 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 10 ms
Switching load DC 24V, UL Class 2 (alternatively, see operating instructions)
Safety class III
Test pulse duration max. 0.3 ms
Test pulse interval 100 ms
Degree of contamination (external, according to EN 60947-1) 3
Solenoid IMP
Input voltage
Guard locking not active (open) 20.4 ... 26.4 V DC
Guard locking active (closed) 0 ... 5 V DC
Current consumption
Guard locking not active (open) 20 ... 50 mA
Monitoring output OD/C
Output type p-switching, short circuit-proof
Output voltage 0.8xUB ... UB V DC
Switching current 1 ... 50 mA
Safety input 1
Current consumption max. 7 mA Safety inputs Fl1A/Fl1B
Safety outputs FO1A / FO1B
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage
HIGH U(FO1A) / U(FO1B) UB-1.5 ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Discrepancy time
both safety outputs max. 10 ms Acc. to EN 60947-5-3
Turn-on time max. 400 ms
Utilization category
DC-13 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Off-state current Ir max. 0.25 mA
Risk time according to EN 60947-5-3
Single device max. 200 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 10 ms
Electrical switching frequency max. 0.25 Hz
Switching current
per safety output FO1A / FO1B 1 ... 150 mA
Test pulse duration max. 0.3 ms (Applies to a load with C<= 30 nF and R<= 20 kohm)
Test pulse interval 100 ms
Operating voltage UB
Operating voltage DC
UUB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
Current consumption
IUB at operating voltage UB = 24 V max. 500 mA

Mechanical values and environment

Approach speed max. 20 m/min
Connection type Plug connector M12, 8-pin
Extraction force 30 N
Ready delay 5.5 s
Actuating force 35 N
Installation orientation any
Switching frequency max. 0.25 Hz
Mechanical life 1 x 10⁶
Overtravel 2 mm
Retention force 15 N
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65/IP67/IP69/IP69K (screwed tight plug connector/mating component)
Ambient temperature
with UB = 24 V DC -20 ... +60 °C
Material
Seals Fluorinated rubber (FKM)
Safety switch housing Reinforced thermoplastic
Locking force Fmax 1300 N
Locking force FZh 1000 N
Guard locking principle BiState

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Control of guard lockingPL d21.03x10-7320 y
Monitoring of the guard positionPL e34.11x10-9420 y
Monitoring of guard lockingPL e34.11x10-9420 y


Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 5,6 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 161496
Item designation CTM-LBI-BR-U-ZZ-SA-P-161496
Gross weight 0,26kg
Customs tariff number 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.