HomeProductsTransponder-coded safety switches with guard lockingCTPCTP-APCTP-I2-AP-U-HA-AZC-SA-126258
Transponder-coded safety switch CTP-AP, M12
- Safety switch with guard locking and integrated evaluation electronics
- Guard locking suitable for process protection only
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4 / PL e according to EN ISO 13849-1
- With plug connector M12
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)
Description
Unicode evaluation
Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.
Guard locking type
CTP‑I2 | Guard locking actuated by power-ON and released by spring force (open-circuit current principle). |
Connector assignment
Dimensional drawings
1 | Auxiliary release |
2 | Locking screw |
3 | LEDs |
4 | Plug connector aligned |
Connection examples
Technical data
Approvals
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | 10 % |
Electrical connection values
Fuse | |
external (solenoid operating voltage IMP) | 0.5 ... 8 A |
external (operating voltage UB) | 0.25 ... 8 A |
Power consumption | 6 W |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
Operating voltage DC | |
UUB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Utilization category | |
DC-13 | 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads) |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV |
Solenoid duty cycle | 100 % |
Switching load | |
according to UL | 24V DC, Class 2 (alternatively, see operating instructions) |
Safety class | III |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Test pulse duration | max. 0.3 ms (Applies to a load with C<= 30 nF and R<= 20 kohm) |
Test pulse interval | min. 100 ms |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring output OD, OI, OL | |
Output type | p-switching, short circuit-proof |
Output voltage | 0.8xUB ... UB V DC |
Switching current | 1 ... 50 mA |
Safety outputs FO1A / FO1B | |
Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1.5 ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Discrepancy time | |
both safety outputs | max. 10 ms Acc. to EN IEC 60947-5-3 |
Turn-on time | max. 400 ms |
Off-state current Ir | max. 0.25 mA |
Switching current | |
per safety output FO1A / FO1B | 1 ... 150 mA |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection type | 1 plug connector M12, 8-pin |
Extraction force | 20 N |
Ready delay | max. 1 s |
Actuating force | 10 N |
Installation orientation | any |
Switching frequency | max. 0.5 Hz |
Mechanical life | 1 x 10⁶ |
Overtravel | 5 mm |
Retention force | 20 N |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP67/IP69/IP69K (When inserted and secured) |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Reinforced thermoplastic |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N (Fzh = Fmax/1.3, depending on the actuator used) |
Guard locking principle | Open-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of the guard position | PL e | - | 4.1x10-9 | 4 | 20 y |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
Accessories
Actuator
Hinged actuator for safety switch CTP/CTA
122671
A-C-H-RL-LS-122671
A-C-H-RL-LS-122671
- Hinged actuator for doors hinged on the left
- Two safety screws included
122672
A-C-H-RR-LS-122672
A-C-H-RR-LS-122672
- Hinged actuator for doors hinged on the right
- Two safety screws included
122675
A-C-H-RO-LS-122675
A-C-H-RO-LS-122675
- Hinged actuator for top-hinged doors
- Two safety screws included
122676
A-C-H-RU-LS-122676
A-C-H-RU-LS-122676
- Hinged actuator for bottom-hinged doors
- Two safety screws included
Connection material
Function expansion
Lock for auxiliary release for safety switch CTP/CTA/TP/STP
084177
AE-K-A1-DULK1-84177
AE-K-A1-DULK1-84177
- Lock unique locking
- Key removable in “unlocked” and “locked” positions
086236
AE-K-A1-IULK1-86236
AE-K-A1-IULK1-86236
- Identical locking
- Key removable in “unlocked” and “locked” positions
109212
AE-K-A1-IUK2-109212
AE-K-A1-IUK2-109212
- Identical locking
- Key can be removed only in “unlocked” position
121917
AE-K-A1-ILK1-121917
AE-K-A1-ILK1-121917
- Identical locking
- Key removable in “locked” position
Wire front release (bowden)
096230
AE-B-A1-02,0-096230
AE-B-A1-02,0-096230
- Can be used as escape release or emergency release
- no automatic return
- Sheath length 2 m (rope length 6 m)
097747
AE-B-A1-02,0-F-097747
AE-B-A1-02,0-F-097747
- Can be used as escape release or emergency release
- automatic return
- Sheath length 2 m (rope length 6 m)
098313
AE-B-A1-03,0-098313
AE-B-A1-03,0-098313
- Can be used as escape release or emergency release
- no automatic return
- Sheath length 3 m (rope length 6 m)
098314
AE-B-A1-04,0-098314
AE-B-A1-04,0-098314
- Can be used as escape release or emergency release
- no automatic return
- Sheath length 4 m (rope length 6 m)
111233
AE-B-A1-03,0-F-111233
AE-B-A1-03,0-F-111233
- Can be used as escape release or emergency release
- automatic return
- Sheath length 3 m (rope length 6 m)
125582
AE-B-A1-06,0-125582
AE-B-A1-06,0-125582
- Can be used as escape release or emergency release
- no automatic return
- Rope length 6 m (without sheath)
124770
AE-B-A1-06,0-F-124770
AE-B-A1-06,0-F-124770
- Can be used as escape release or emergency release
- automatic return
- Rope length 6 m (without sheath)
Metal bolt
Bolt for safety switch CTP, CTA
123653
RIEGEL CTP-AC-123653
RIEGEL CTP-AC-123653
- Steel bolt
- For doors hinged on the right and left
- Can be locked in open position with padlocks
- Actuator included
137354
RIEGEL CTP-AC-C2308-137354
RIEGEL CTP-AC-C2308-137354
- Steel bolt
- For doors hinged on the right and left
- Can be locked in open position with padlocks
- Actuator included
- Bolt without door stop, suitable for swing doors
Mounting accessories
Efficient protection against tampering for safety switch mounting
161344
AM-C-SW4-V3-161344
AM-C-SW4-V3-161344
- Plastic inserts for hexagon socket screws a/f 4
- Efficient protection against tampering for safety switch mounting
- The packaging includes inserts for 18 screws
161348
AM-C-SW5-V3-161348
AM-C-SW5-V3-161348
- Plastic inserts for hexagon socket screws a/f 5
- Efficient protection against tampering for safety switch mounting
- The packaging includes inserts for 18 screws
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2123042
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001501
Version
Language
Size
0,1 MB
Instructions
Operating Instructions Transponder-Coded Safety Switch with Guard Locking for Process Protection CTP-I.-AP Unicode/Multicode
Doc. no.
Version
Language
Size
Operating Instructions Transponder-Coded Safety Switch with Guard Locking for Process Protection CTP-I.-AP Unicode/Multicode
Doc. no.
2126290
Version
08-07/24
Language
Size
3,3 MB
Mode d'emploi Interrupteur de sécurité à codage par transpondeur avec interverrouillage pour la protection du process CTP-I.-AP Uni-/multicode
Doc. no.
2126290
Version
08-07/24
Language
Size
3,3 MB
Manual de instrucciones Interruptor de seguridad codificado por transponder con bloqueo para la protección de procesos CTP-I.-AP Unicode/Multicode
Doc. no.
2126290
Version
08-07/24
Language
Size
3,3 MB
Betriebsanleitung Transpondercodierter Sicherheitsschalter mit Zuhaltung für den Prozessschutz CTP-I.-AP Uni-/Multicode
Doc. no.
2126290
Version
08-07/24
Language
Size
3,3 MB
Istruzioni di impiego Finecorsa di sicurezza con codifica a transponder con meccanismo di ritenuta per la protezione del processo CTP-I.-AP Unicode/Multicode
Doc. no.
2126290
Version
08-07/24
Language
Size
3,3 MB
操作説明書 トランスポンダー コーデッド安全スイッチ プロセス保護用ガードロックあり
CTP-I.-AP ユニコード/マルチコード
Doc. no.
2126290
Version
08-07/24
Language
Size
3,7 MB
Other Documents
Approvals and certificates
DGUV
Doc. no.
Version
Language
Size
DGUV
Doc. no.
Version
Language
Size
2,4 MB
FCC
Doc. no.
Version
Language
Size
FCC
Doc. no.
Version
Language
Size
0,1 MB
IC
Doc. no.
Version
Language
Size
IC
Doc. no.
Version
Language
Size
1,8 MB
c UL us
Doc. no.
Version
Language
Size
c UL us
Doc. no.
Version
Language
Size
0,3 MB
Sales documents
UQS document
Bescheinigung
Doc. no.
Version
Language
Size
Bescheinigung
Doc. no.
ECO2123565
Version
Language
Size
0,2 MB
CAD data
Ordering data
Ordernumber | 126258 |
Item designation | CTP-I2-AP-U-HA-AZC-SA-126258 |
Gross weight | 0,588kg |
Customs tariff number | 85365019000 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |