HomeProductsTransponder-coded safety switches with guard lockingCTPCTP-APCTP-L1-AP-U-HA-AZ-SA-EX-136675
Transponder-coded safety switch CTP-AP, M12, ATEX
- ATEX version
- Suitable for use in zones 2 and 22 (gases and dusts)
- Safety switch with guard locking and integrated evaluation electronics
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4 / PL e according to EN ISO 13849-1
- With plug connector M12
- Unicode
- Door monitoring output OD
- Guard lock monitoring output OL
- Approach directions A, B and C (delivery state)
Description
Unicode evaluation
Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.
Guard locking type
CTP‑L1 | Guard locking actuated by spring force and power-ON released (closed-circuit current principle). |
Connector assignment
Dimensional drawings
1 | Auxiliary release |
2 | Locking screw |
3 | LEDs |
4 | Protective plate |
5 | Grounding terminal - for preventing electrostatic charging. Ground switch via cable. Cable cross-section 4...6 mm² |
Connection examples
Technical data
Approvals
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | 10 % |
Electrical connection values
Fuse | |
external (operating voltage UB) | 0.25 ... 8 A |
external (solenoid operating voltage IMP) | 0.5 ... 8 A |
Power consumption | 6 W |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
Operating voltage DC | |
UUB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Utilization category | |
DC-13 | 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads) |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV |
Solenoid duty cycle | 100 % |
Switching load | |
according to UL | 24V DC, Class 2 (alternatively, see operating instructions) |
Safety class | |
EN IEC 61140 | III |
Current consumption | |
IIMP | 400 mA |
IUB | 40 mA |
Test pulse duration | max. 0.3 ms (Applies to a load with C<= 30 nF and R<= 20 kohm) |
Test pulse interval | min. 100 ms |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring output OD, OL | |
Output type | p-switching, short circuit-proof |
Output voltage | 0.8xUB ... UB V DC |
Switching current | 1 ... 50 mA |
Safety outputs FO1A / FO1B | |
Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1.5 ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Discrepancy time | |
both safety outputs | max. 10 ms Acc. to EN IEC 60947-5-3 |
Turn-on time | max. 400 ms |
Off-state current Ir | max. 0.25 mA |
Switching current | |
per safety output FO1A / FO1B | 1 ... 150 mA |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection type | 1 plug connector M12, 8-pin |
Extraction force | 20 N |
Ready delay | max. 1 s |
Actuating force | 10 N |
Installation orientation | any |
Switching frequency | max. 0.5 Hz |
Mechanical life | 1 x 10⁶ |
Overtravel | 5 mm |
Retention force | 20 N |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65/IP66 (screwed tight plug connector/mating component) |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Material | |
Safety switch housing | Reinforced thermoplastic |
Switch head cover | Die-cast zinc |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N (Fzh = Fmax/1.3, depending on the actuator used) |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of guard locking | PL e | - | 4.1x10-9 | 4 | 20 y |
PL | Maximum SIL | Category | Mission time | |
---|---|---|---|---|
Control of guard locking | Depending on external control of guard locking | 20 y |
Miscellaneous
Explosion protection | |
incl. cover hood | II3G Ex ec IIC T4 Gc X / II3D Ex tc IIIC T110°C Dc X |
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
Accessories
Actuator
Hinged actuator for safety switch CTP-EX, ATEX
166340
A-C-H-RL-LS-EX-166340
A-C-H-RL-LS-EX-166340
- Hinged actuator for doors hinged on the left
- ATEX version
- Suitable for use in zones 2 and 22 (gases and dusts)
- Two safety screws included
166341
A-C-H-RR-LS-EX-166341
A-C-H-RR-LS-EX-166341
- Hinged actuator for doors hinged on the right
- ATEX version
- Suitable for use in zones 2 and 22 (gases and dusts)
- Two safety screws included
Connection material
Mounting accessories
Efficient protection against tampering for safety switch mounting
161344
AM-C-SW4-V3-161344
AM-C-SW4-V3-161344
- Plastic inserts for hexagon socket screws a/f 4
- Efficient protection against tampering for safety switch mounting
- The packaging includes inserts for 18 screws
161348
AM-C-SW5-V3-161348
AM-C-SW5-V3-161348
- Plastic inserts for hexagon socket screws a/f 5
- Efficient protection against tampering for safety switch mounting
- The packaging includes inserts for 18 screws
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2127608
Version
Language
Size
0,2 MB
Instructions
Operating Instructions Transponder-Coded Safety Switch With Guard Locking CTP-AP-...-EX Unicode/Multicode
Doc. no.
Version
Language
Size
Operating Instructions Transponder-Coded Safety Switch With Guard Locking CTP-AP-...-EX Unicode/Multicode
Doc. no.
2127610
Version
05-08/20
Language
Size
2,0 MB
Mode d'emploi Interrupteur de sécurité à codage par transpondeur avec interverrouillage CTP-AP-...-EX uni-/multicode
Doc. no.
2127610
Version
05-08/20
Language
Size
2,0 MB
Manual de instrucciones Interruptor de seguridad con codificación por transponder con bloqueo CTP-AP-...-EX Unicode/Multicode
Doc. no.
2127610
Version
05-08/20
Language
Size
2,0 MB
Betriebsanleitung Transpondercodierter Sicherheitsschalter mit Zuhaltung CTP-AP-...-EX Uni-/Multicode
Doc. no.
2127610
Version
05-08/20
Language
Size
2,0 MB
Istruzioni di impiego Finecorsa di sicurezza con codifica a transponder con meccanismo di ritenuta CTP-AP-...-EX Uni-/Multicode
Doc. no.
2127610
Version
05-08/20
Language
Size
2,0 MB
Other Documents
Approvals and certificates
FCC
Doc. no.
Version
Language
Size
FCC
Doc. no.
Version
Language
Size
0,1 MB
c UL us
Doc. no.
Version
Language
Size
c UL us
Doc. no.
Version
Language
Size
0,3 MB
Sales documents
ATEX Interrupteurs de sécurité pour atmosphères explosibles
Doc. no.
Version
Language
Size
ATEX Interrupteurs de sécurité pour atmosphères explosibles
Doc. no.
136806
Version
06-07/24
Language
Size
1,4 MB
ATEX Safety switches for potentially explosive atmospheres
Doc. no.
Version
Language
Size
ATEX Safety switches for potentially explosive atmospheres
Doc. no.
136805
Version
06-07/24
Language
Size
1,4 MB
ATEX Sicherheitsschalter für explosionsgefährdete Bereiche
Doc. no.
Version
Language
Size
ATEX Sicherheitsschalter für explosionsgefährdete Bereiche
Doc. no.
136804
Version
06-07/24
Language
Size
1,4 MB
Ordering data
Ordernumber | 136675 |
Item designation | CTP-L1-AP-U-HA-AZ-SA-EX-136675 |
Gross weight | 0,99kg |
Customs tariff number | 85365019000 |