Non-contact safety switches CES-I-AR-.-C14-…, with cable end sleeves
- Safety switch with integrated evaluation electronics
- Safety switch CES-C04 encapsulated in epoxy resin
- Tested for material resistance in accordance with Ecolab specifications
- Up to 20 switches in series
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces
- Connecting cable PUR, 20 m, with cable end sleeves
- Multicode
- Monitoring output OD
Description
Actuating range
Typical operating distance
(Only in conjunction with actuator CES-A-BBN-C14)
For a side approach direction for the actuator and safety switch, a minimum distance of s = 10 mm must be maintained so that the actuating range of the side lobes is not entered.
Multicode evaluation
Every suitable actuator is detected by the switch.
Category according to EN 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4/PL e according to EN 13849-1
Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
Terminal assignment
Designation | Function | Connecting cable conductor coloring |
---|---|---|
FI1B | Enable input for channel 2 | WH |
UB | Power supply, DC 24 V | BN |
FO1A | Safety output, channel 1 | GN |
FO1B | Safety output, channel 2 | YE |
OD | Monitoring output | GY |
FI1A | Enable input for channel 1 | PK |
0 V | Ground, DC 0 V | BU |
RST | Reset input | RD |
Dimensional drawings
1 | Active face |
2 | LED status indication |
3 | Cable end sleeve on cable end |
Connection examples
Technical data
Approvals
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | <= 10 |
Electrical connection values
Fuse | |
external (operating voltage) | 0.25 ... 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Operating voltage DC | |
UB | 24 V DC -15% ... +15% regulated, residual ripple<5%, PELV |
Turn-on time | |
Safety outputs | max. 400 ms |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Risk time according to EN 60947-5-3 | max. 260 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 5 ms |
Safety class | III |
Current consumption | max. 35 mA (without taking into account the load currents on the monitoring output and the safety outputs) |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring output OD | |
Output type | Semiconductor output, p-switching, short circuit-proof |
Output voltage | 0.8 x UB ... UB V DC |
Switching current | max. 50 mA |
Safety outputs FO1A / FO1B | |
Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
LOW U (FO1A) / U (FO1B) | 0 ... 1 V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
HIGH U (FO1A) / U (FO1B) | UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
rated conditional short-circuit current | 100 A |
Discrepancy time | max. 10 ms |
Utilization category | |
DC-13 | 24 V 200 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Off-state current Ir | max. 0.25 mA |
Switching current | |
per safety output | 1 ... 200 mA |
Test pulse duration | max. 1.0 ms (Applies to a load with C<= 30 nF and R<= 20 kohm) |
Test pulse interval | min. 140 ms |
Mechanical values and environment
Connection type | Connecting cable PUR, length 20 m |
Tightening torque | |
Fixing screws | 2 Nm |
Ready delay | 10 s |
Dynamic bending radius | 10 x cable diameter |
Static bending radius | 5 x cable diameter |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Mounting distance | |
between switches | min. 80 mm |
Mounting type | non-flush on metal |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65/IP67/IP69/IP69K |
Ambient temperature | |
with UB = 24 V DC | 0 ... +65 °C |
Material | |
Housing | 2-component epoxy resin |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of the guard position | PL e | - | 4.1x10-9 | 4 | 20 y |
In combination with actuator CES-A-BBN-C14-160441
Switch-on distance | |
Installation position A / in z direction | max. 20 mm |
Installation position D / in z direction | max. 15 mm |
Secured switch-off distance sar | |
Installation position A / in y direction | max. 72 mm |
Installation position D / in y direction | max. 68 mm |
Installation position D / in x/z direction | max. 60 mm |
Installation position A / in x/z direction | max. 64 mm |
Secured switching distance sao | |
Installation position D / in z direction | max. 5 mm |
Installation position A / in z direction | max. 10 mm |
Accessories
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Other Documents
Homologation
Homologación
EAC
Homologação
Omologazione
认证
認可
승인
Сертификат
Atest
Engedély
Разрешително
Godkendelse
Heakskiit
Hyväksyntä
Έγκριση
Odobrenje
Atļauja
Patvirtinimas
Goedkeuring
Godkjenning
Dopuszczenie
Godkännande
Dovoljenje
Povolenie
Onay
Дозвіл
Autorisation
Aprobación
ECOLAB
Aprovação
审批
承認
승인
Schválení
Ordering data
Ordernumber | 162596 |
Item designation | CES-I-AR-M-C14-U20-162596 |
Gross weight | 0,073kg |
Customs tariff number | 85365019000 |
ECLASS | 27-27-24-03 Safety-related transponder switch |