CES-I-AR-M-C14-U20-162596 (Order no. 162596)

Non-contact safety switches CES-I-AR-.-C14-…, with cable end sleeves

  • Safety switch with integrated evaluation electronics
  • Safety switch CES-C04 encapsulated in epoxy resin
  • Tested for material resistance in accordance with Ecolab specifications
  • Up to 20 switches in series
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • Three active faces
  • Connecting cable PUR, 20 m, with cable end sleeves
  • Multicode
  • Monitoring output OD
CES-I-AR-M-C14-U20-162596 (Order no. 162596)

Description

Installation position

Permissible installation position

Actuating range

Typical operating distance
(Only in conjunction with actuator CES-A-BBN-C14)

<p>Typical operating distance<br>(Only in conjunction with actuator CES-A-BBN-C14)</p>

For a side approach direction for the actuator and safety switch, a minimum distance of s = 10 mm must be maintained so that the actuating range of the side lobes is not entered.

Multicode evaluation

Every suitable actuator is detected by the switch.

Category according to EN 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4/PL e according to EN 13849-1

Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated.

LED indicator

STATE

Status LED

DIA

Diagnostics LED

Terminal assignment

DesignationFunctionConnecting cable conductor coloring
FI1BEnable input for channel 2WH
UBPower supply, DC 24 VBN
FO1ASafety output, channel 1GN
FO1BSafety output, channel 2YE
ODMonitoring outputGY
FI1AEnable input for channel 1PK
0 VGround, DC 0 VBU
RSTReset inputRD
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1Active face
2LED status indication
3Cable end sleeve on cable end

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E346349_1/1ECOLAB__

Workspace

Repeat accuracy R
according to EN 60947-5-2 <= 10

Electrical connection values

Fuse
external (operating voltage) 0.25 ... 8 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp 1.5 kV
Operating voltage DC
UB 24 V DC -15% ... +15% regulated, residual ripple<5%, PELV
Turn-on time
Safety outputs max. 400 ms
EMC protection requirements Acc. to EN IEC 60947-5-3
Risk time according to EN 60947-5-3 max. 260 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Safety class III
Current consumption max. 35 mA (without taking into account the load currents on the monitoring output and the safety outputs)
Degree of contamination (external, according to EN 60947-1) 3
Monitoring output OD
Output type Semiconductor output, p-switching, short circuit-proof
Output voltage 0.8 x UB ... UB V DC
Switching current max. 50 mA
Safety outputs FO1A / FO1B
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage
LOW U (FO1A) / U (FO1B) 0 ... 1 V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
HIGH U (FO1A) / U (FO1B) UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
rated conditional short-circuit current 100 A
Discrepancy time max. 10 ms
Utilization category
DC-13 24 V 200 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Off-state current Ir max. 0.25 mA
Switching current
per safety output 1 ... 200 mA
Test pulse duration max. 1.0 ms (Applies to a load with C<= 30 nF and R<= 20 kohm)
Test pulse interval min. 140 ms

Mechanical values and environment

Connection type Connecting cable PUR, length 20 m
Tightening torque
Fixing screws 2 Nm
Ready delay 10 s
Dynamic bending radius 10 x cable diameter
Static bending radius 5 x cable diameter
Installation orientation any
Switching frequency max. 1 Hz
Mounting distance
between switches min. 80 mm
Mounting type non-flush on metal
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65/IP67/IP69/IP69K
Ambient temperature
with UB = 24 V DC 0 ... +65 °C
Material
Housing 2-component epoxy resin

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionPL e-4.1x10-9420 y


In combination with actuator CES-A-BBN-C14-160441

Switch-on distance
Installation position A / in z direction max. 20 mm
Installation position D / in z direction max. 15 mm
Secured switch-off distance sar
Installation position A / in y direction max. 72 mm
Installation position D / in y direction max. 68 mm
Installation position D / in x/z direction max. 60 mm
Installation position A / in x/z direction max. 64 mm
Secured switching distance sao
Installation position D / in z direction max. 5 mm
Installation position A / in z direction max. 10 mm

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 7,5 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 162596
Item designation CES-I-AR-M-C14-U20-162596
Gross weight 0,073kg
Customs tariff number 85365019000
ECLASS 27-27-24-03 Safety-related transponder switch

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.