CES-AR-CR2-CH-SA-105745 (Order no. 105745)

Non-contact safety switch CES-AR-CR2-... , plug connector M12, PUR

  • Safety switch with integrated evaluation electronics
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Door hinge right
  • Category 4 / PL e according to EN ISO 13849-1
  • Connecting cable PUR, 1 m, plug connector M12, 8-core
  • Multicode
  • Two safety screws M4x14 included
CES-AR-CR2-CH-SA-105745 (Order no. 105745)

Description

Short circuit monitoring

The switch generates its own clock signal on the output lines OA/OB.

Pay attention to this aspect when connecting to control systems and relays.

Multicode evaluation

Every suitable actuator is detected by the switch.

Category according to EN 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4/PL e according to EN 13849-1

Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

LED indicator

STATE

Status LED

DIA

Diagnostics LED

Additional connections

OUT

Monitoring output (semiconductor)

RST

Reset input

Approach directions

<p>Approach directions</p>

Typical actuating range

(actuator CES-A-BLN... in conjunction with safety switch CES-AR-C.2-... in case of mounting on plastic)

For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.

Attention:

The actuating range may vary depending on the substrate material and installation situation.

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1IBEnable input for channel 2WH
2UBPower supply, DC 24 VBN
3OASafety output, channel 1GN
4OBSafety output, channel 2YE
5OUTMonitoring outputGY
6IAEnable input for channel 1PK
70 VGround, DC 0 VBU
8RSTReset inputRD
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1Active face
2Fastening lug with reinforcement plate
3LED status indication
4Active face
5Coding lug

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E346349_1/1

Workspace

Repeat accuracy R
according to EN 60947-5-2 <= 10

Electrical connection values

Fuse
external (operating voltage) 0.25 ... 8 A
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 1.5 kV
Operating voltage DC
UB 24 V DC -15% ... +15% regulated, residual ripple<5%
Turn-on time
Safety outputs max. 400 ms
EMC protection requirements Acc. to EN IEC 60947-5-3
Risk time according to EN 60947-5-3 max. 260 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Safety class III
Current consumption max. 50 mA (without taking into account the load currents on the monitoring output and the safety outputs)
Degree of contamination (external, according to EN 60947-1) 3
Monitoring output OUT
Output type p-switching, short circuit-proof
Output voltage 0.8 x UB ... UB V DC
Switching current max. 50 mA
Safety outputs OA / OB
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage
HIGH U(OA,OB) UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
LOW U(OA,OB) 0 ... 1 V DC
rated conditional short-circuit current 100 A
Discrepancy time max. 10 ms
Utilization category
DC-13 24 V 200 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Off-state current Ir max. 0.25 mA
Switching current
per safety output 1 ... 200 mA
Test pulse duration max. 1 ms (Applies to a load with C<= 30 nF and R<= 20 kohm)
Test pulse interval min. 140 ms

Mechanical values and environment

Connection type Connecting cable PUR, length 1 m, with plug connector M12, 8-pin
Tightening torque
Fixing screws max. 1 Nm
Ready delay 10 s
Dynamic bending radius 10 x cable diameter
Static bending radius 5 x cable diameter
Installation orientation any
Switching frequency max. 1 Hz
Mounting distance
between switches min. 120 mm
Mounting type non-flush on metal
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67
Cable ambient temperature (dynamic) -25 ... +65 °C
Cable ambient temperature (static) -25 ... +65 °C
Material
Housing Plastic, PBT

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionPL e-1.9x10-9420 y


Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures

In combination with actuator CES-A-BDN-06-104730

Switch-on distance 19 mm
Secured switch-off distance sar
in y direction max. 60 mm
in x/z direction max. 40 mm
Secured switching distance sao min. 14 mm
Switching hysteresis 1 ... 2 mm

In combination with actuator CES-A-BLN-R2-100776, CES-A-BLN-U2-103450, CES-A-BLN-L2-104510, CES-A-BLN-U2-112710

Switch-on distance 15 mm
Secured switch-off distance sar
in y direction max. 60 mm
in x/z direction max. 40 mm
Secured switching distance sao min. 10 mm
Switching hysteresis 1 ... 2 mm

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 6,8 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 105745
Item designation CES-AR-CR2-CH-SA-105745
Gross weight 0,11kg
Customs tariff number 85365019000
ECLASS 27-27-24-03 Safety-related transponder switch

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com

Cookie notice

We use technically necessary cookies that are essential for the operation of the website. In addition, we use a statistics cookie to analyze the use of our website and to continuously improve our offer. You can decide for yourself whether you wish to consent to the use of the statistics cookie. Further information can be found in our privacy policy.