Data carrier CIS3 horizontal
Ismertetés
Assembly Instructions
On mounting the read head and data carrier, it is to be ensured the crossing direction as per the direction of the arrow on the active face of the read head or read/write head is observed.
Programming
The data carrier can be written (programmed) for read-only operation with a maximum of 32 hexadecimal digits (value from 0hexto Fhex) on customer request. Standard filler digit after the customer-specific defined digits is Ehex.
The housing is permanently laser marked with the digits programmed (not including filler digits) in hexadecimal notation.
Dimensional drawings
Műszaki adatok
Approvals
Electrical connection values
Number of read cycles | not limited |
Number of write cycles | max. 100000 |
Data retention time | max. 10 y at +50 °C |
Power supply | Inductive via read head |
Storage capacity | 16 B read/write (storage capacity 128 bits or 32 digits) |
Mechanical values and environment
Mounting type | screws, surface mounting |
Degree of protection | IP67 |
Ambient temperature | -40 ... +85 °C |
Material | |
Housing | PPS plastic |
Method of operation | Operating frequency 125kHz |
Letöltések
Teljes csomag
Minden fontos dokumentum letöltése egyetlen kattintással.
Tartalom:
- A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
- A használati utasítást kiegészítő adatlapok
- A megfelelőségi nyilatkozat
Egyedi dokumentumok
Egyéb dokumentumok
Rendelési adatok
Rend. sz. | 040045 |
Cikk neve | CIS3P35X16SH01KH |
Súly | 0,005kg |
Vámtarifaszám | 85389099990 |
ECLASS | 27-28-04-02 Identification, RFID Transponder |