SN02D12-502-MC1856 (Rend. sz. 089550)

Series SN... 12 mm, mechanical

  • Plunger spacing 12 mm
  • Upright housing, small flange
  • Degree of protection IP67 according to IEC 60529
SN02D12-502-MC1856 (Rend. sz. 089550)

Ismertetés

Switching element

ES 502 E

Snap-action switching contact 1 NC + 1 NO

Dimension drawing
Dimension drawing
Wiring diagram ES 502 E
Wiring diagram ES 502 E
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1Cable 3x0.75, color code DIN 47100
2Operating point
3Free position
4Dog
5View of connection side
6Male Han Q5/0, degree of protection IP44
7Switching element: ES502E snap-action switching contact with 1 normally open and 1 normally closed contact. Double gap contacts, electrically isolated switching contacts.
8Housing without earth conductor!

Connection examples

Connection examples

Connection examples

Connection examples

Műszaki adatok

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/6CCC_2020980305000540_CQC2008010305306206

Electrical connection values

Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 2 kV
Utilization category
AC-15 6 A 50 V
DC-13 6 A 24 V
Short circuit protection according to IEC 60269-1 8A gG
Switching current
min. at DC 12V min. 10 mA

Mechanical values and environment

Approach speed 0.01 ... 40 m/min
Connection type 1 x plug connector Han Q5/0 (Harting plug connector Han Q5/0, 5-pin; only pins 1, 3 and 4 used; with cable 3,000 mm (3x0.75 mm²). Mounted on right.)
Number NC contacts 2
Number of switching elements 2
Number of NO contacts 2
Design upright
Actuating element Chisel plunger
Actuating force min. 20 N
Installation orientation any
Mechanical life 30 x 10⁶
Contact bounce time < 3ms
Switching principle Snap-action switching contact
Operating point accuracy ± 0,002 (The reproducible operating point accuracy refers to the axial travel of the plunger after the switching element ES 502 E has been run-in with approx. 2,000 operating cycles.)
Contact closing time max. 4 ms
Degree of protection IP67 (only in the inserted state, with the related mating connector)
Plunger spacing 12 mm
Ambient temperature -5 ... +80 °C
Material
Contact Silver alloy, gold flashed
Housing Die-cast aluminum, anodized

Miscellaneous

C number
C1856
Additional information Housing without earth conductor! (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN IEC 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent insulation measures.)

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 2,0 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 089550
Cikk neve SN02D12-502-MC1856
Súly 0,578kg
Vámtarifaszám 85365019000
ECLASS 27-27-06-02 Multi-position switch

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu

Cookie-értesítés

Műszakilag szükséges sütiket használunk, amelyek a weboldal működéséhez elengedhetetlenek. Ezenkívül statisztikai sütit használunk a weboldalunk használatának elemzésére és kínálatunk folyamatos fejlesztésére. Ön maga döntheti el, hogy beleegyezik-e a statisztikai cookie használatába. További információk az adatvédelmi szabályzatunkban találhatók.