GSBF02R12-502-MC1806/V10 (Rend. sz. 094147)

Series GSBF... 12/16 mm, mechanical

  • Plunger spacing 12 or 16 mm
  • Upright housing
  • Degree of protection IP67 according to IEC 60529
  • LED function display optional
GSBF02R12-502-MC1806/V10 (Rend. sz. 094147)

Ismertetés

Switching elements

ES 502 E

Snap-action switching contact 1 NC + 1 NO

ES 508

Slow-action switching contact 1 NC

ES 514

Snap-action switching contact 1 NC + 1 NO

On the usage of safety switching elements, the dog distance must be maintained to achieve the positively driven travel. The dogs must be positively mounted according to EN1088, i.e. riveted, welded or secured in some other way against becoming loose.

LED function display (optional)

Function displays are available for the following voltage ranges (see accessories)

LE060

12 ... 60 V AC/DC

LE110

110 V AC ±15%

LE220

220 V AC ±15%

Dimension drawing
Dimension drawing
Wiring diagram ES514
Wiring diagram ES514
Wiring diagram ES 508
Wiring diagram ES 508
Wiring diagram ES 502 E
Wiring diagram ES 502 E

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Connection examples

Connection examples

Connection examples

Connection examples

Műszaki adatok

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/6CCC_2020980305000540_CQC2008010305306206

Electrical connection values

Connection cross section 0.34 ... 1.5 mm²
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2.5 kV
Utilization category
AC-15 6 A 230 V
DC-13 6 A 24 V
AC-12 8 A 250 V
Short circuit protection according to IEC 60269-1 8A gG
Switching current
min. at DC 12V min. 10 mA
thermal rated current Ith 8 A

Mechanical values and environment

Approach speed 0.01 ... 80 m/min
Connection type 2 x M25 x 1.5
Number NC contacts 2
Number of switching elements 2
Number of NO contacts 2
Design upright
Actuating element Roller plunger (Slide bearing)
Actuating force min. 20 N
Installation orientation any
Mechanical life 30 x 10⁶
Contact bounce time < 3ms
Roller diameter 8
Switching principle Snap-action switching contact
Operating point accuracy ± 0,01 (The reproducible operating point accuracy refers to the axial travel of the plunger after the switching element ES 502 E has been run-in with approx. 2,000 operating cycles.)
Contact closing time max. 4 ms
Degree of protection IP67
Plunger spacing 12 mm
Ambient temperature -5 ... +80 °C
Material
Contact Silver alloy, gold flashed
Housing Die-cast aluminum, anodized

Miscellaneous

C number
C1806

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 2,7 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 094147
Cikk neve GSBF02R12-502-MC1806/V10
Súly 5,356kg
Vámtarifaszám 85365019000
ECLASS 27-27-06-02 Multi-position switch

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu

Cookie-értesítés

Műszakilag szükséges sütiket használunk, amelyek a weboldal működéséhez elengedhetetlenek. Ezenkívül statisztikai sütit használunk a weboldalunk használatának elemzésére és kínálatunk folyamatos fejlesztésére. Ön maga döntheti el, hogy beleegyezik-e a statisztikai cookie használatába. További információk az adatvédelmi szabályzatunkban találhatók.