EUCHNER – More than safety.
EUCHNER – More than safety.

CET1-AX-LRA-00-50X-SC (Rend. sz. 102988)

Read head CET1-AX-..., 2 plug connectors M8, with guard locking and guard lock monitoring

  • Read head with guard locking
  • Locking force up to 6500 N
  • Up to category 4 / PL e according to EN ISO 13849-1
  • With 2 plug connectors M8
  • 2 LEDs (1 freely configurable)
  • Approach direction A (delivery state)
CET1-AX-LRA-00-50X-SC (Rend. sz. 102988)

Ismertetés

Combination options

Suitable for connection to a CES-AZ evaluation unit

Approach direction

Horizontal

Can be adjusted in 90° steps

Solenoid operating voltage

  • DC 24 V +10%, -15%

Guard locking type

CET1

Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid.

LED function display

LED red

illuminates when solenoid is switched on

LED green

freely configurable

Category according to EN ISO 13849-1

Important: The category according to EN ISO 13849-1 depends on the evaluation unit used and on the installation orientation.

Notes

  • Special connecting cables from EUCHNER are required for the connection. Please take into account in the order!
  • The device may be operated only in conjunction with the actuator CET-A-.... The actuator must be ordered separately.

Auxiliary release

This is used for releasing the guard locking with the aid of a tool. The auxiliary release must be sealed to prevent tampering (for example with sealing lacquer).

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Műszaki adatok

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/5DGUV_ET 20018_ET 20019

Electrical connection values

Power consumption
Solenoid 11 W
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 0.8 kV
Operating voltage DC
LED 24 V DC -15% ... +15% reverse polarity protected
Solenoid operating voltage DC
UCM 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV
Solenoid duty cycle 100 %
Safety class
EN IEC 61140 III
Current consumption
LED max. 6 mA
ICM 450 mA Solenoid
Degree of contamination (external, according to EN 60947-1) 3

Mechanical values and environment

Approach speed max. 20 m/min
Connection type 2 plug connectors M8, 4-pin and 3-pin
Installation orientation any
Switching frequency 1 Hz
Degree of freedom X ±5 mm
Degree of freedom Y ±5 mm
Degree of freedom Z ±4 mm
Mechanical life 2 x 10⁶
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67 (with screwed tight plug connector)
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Material
Ramp Stainless steel
Safety switch Die-cast aluminum
Locking force Fmax 6500 N
Locking force FZh 5000 N
Guard locking principle Closed-circuit current principle

Tartozékok

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 4,9 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 102988
Cikk neve CET1-AX-LRA-00-50X-SC
Súly 1,1kg
Vámtarifaszám 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu

Cookie-értesítés

Műszakilag szükséges sütiket használunk, amelyek a weboldal működéséhez elengedhetetlenek. Ezenkívül statisztikai sütit használunk a weboldalunk használatának elemzésére és kínálatunk folyamatos fejlesztésére. Ön maga döntheti el, hogy beleegyezik-e a statisztikai cookie használatába. További információk az adatvédelmi szabályzatunkban találhatók.