Read head CEM-A-LE05H-S2... with guard locking without guard lock monitoring with adjustable adhesive force
- Read head with guard locking without guard lock monitoring
- Locking force 650 N
- Adjustable adhesive force
- Up to category 4 according to EN ISO 13849-1
- Two safety screws M5x16 included

Ismertetés
Combination options
Suitable for connection to a CES-AZ evaluation unit
Adjustable adhesive force
This version has an adhesive force also with the guard locking switched off. In this way it is intended, for example, to prevent the safety door from opening due to vibration or similar. The adhesive force can be adjusted using a programming adapter to 70 N, 110 N or 150 N.
Important: To change the preset adhesive force, you will need a programming adapter.
Approach direction

Typical actuating range

Note assured release distance sar = 20 mm for internal component failure. Safety outputs are safely switched off.



Dimensional drawings

Connection examples

Connection examples

CES evaluation unit | |
X1.1 | U |
X1.2 | NC |
X1.3 | 0 V/GND |
X1.4 | Functional earth |
X3.1 | Data line |
X3.3 | Data line |
X3.4 | SH (screen) |
Műszaki adatok
Approvals


Workspace
Secured switch-off distance sar | max. 20 mm |
Secured switching distance sao | |
with center offset m= ±2.5 mm | 0 mm |
Center offset | -2.5 ... +2.5 mm |
Switching hysteresis | |
with center offset m=0 | 0.7 mm |
Electrical connection values
Power consumption | 2.8 W |
Operating voltage DC | |
UB | 24 V DC -15% ... +10% |
UCM | 24 V DC -15% V DC ... +10% V DC |
Solenoid duty cycle | 100 % |
Current consumption | |
at UB at UCM=0 V | 25 mA |
at UCM at 24 V | 10 mA |
at UB at UCM=24 V | 100 mA |
Mechanical values and environment
Connection type | |
X1, solenoid (yellow LED integrated in the plug) | Plug connector M8x1, 4-pin, plug (with snap-action/screw terminal) |
X3, read head | Plug connector M8x1, 3-pin, plug (with snap-action/screw terminal) |
Installation orientation | any |
Switching frequency | |
Solenoid | max. 1 Hz |
Adhesive force | |
adjustable | 70/110/150 (Delivery state 110 N) N |
Cable length | max. 25 m |
Mechanical life | |
in case of use as door stop, and 1 Joule impact energy | 1 x 10⁶ |
Degree of protection | IP67 |
Ambient temperature | -25 ... +50 °C |
Material | |
Housing | Die-cast aluminum |
Solenoid | Steel, nickel plated |
Read head | Plastic (PPS) |
Locking force F | |
(not monitored, in axial direction) at UCM=24 V | 650 N |
Guard locking principle | Open-circuit current principle |
Tartozékok
Letöltések
Teljes csomag
Minden fontos dokumentum letöltése egyetlen kattintással.
Tartalom:
- A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
- A használati utasítást kiegészítő adatlapok
- A megfelelőségi nyilatkozat
Egyedi dokumentumok



Mode d'emploi Tête de lecture CEM-A-LE05H-S2
Manual de instrucciones Cabeza de lectura CEM-A-LE05H-S2
Betriebsanleitung Lesekopf CEM-A-LE05H-S2

Egyéb dokumentumok


Rendelési adatok
Rend. sz. | 104606 |
Cikk neve | CEM-A-LE05H-S2-104606 |
Súly | 0,432kg |
Vámtarifaszám | 85365019000 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |