Read head CET1-AX-... M12, with guard locking and guard lock monitoring, escape release and lockout bar
- Read head with guard locking
- Locking force up to 6500 N
- Up to category 4 / PL e according to EN ISO 13849-1
- With plug connector M12
- With escape release, 75 mm long
- With lockout bar
- 2 LEDs (1 freely configurable)
- Approach direction A (delivery state)

Ismertetés
Lockout mechanism
The lockout bar can be used to prevent maintenance personnel from being unintentionally locked in the danger zone, for example.
Important: The lockout bar is not a safety function..
This device with lockout bar possesses no auxiliary release.
Solenoid operating voltage
- DC 24 V +10%, -15%
Guard locking type
CET1 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. |
LED function display
LED red | illuminates when solenoid is switched on |
LED green | freely configurable |
Category according to EN ISO 13849-1
Important: The category according to EN ISO 13849-1 depends on the evaluation unit used and on the installation orientation.

Notes
- Special connecting cables from EUCHNER are required for the connection. Please take into account in the order!
- The read head CET may be operated only in conjunction with the actuator CET-A-BWK-50X. The actuator must be ordered separately.
Escape release
This is used for manual release of guard locking from the danger zone without tools.


Dimensional drawings

Connection examples

Műszaki adatok
Approvals

Electrical connection values
Power consumption | |
Solenoid | 11 W |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Operating voltage DC | |
LED | 24 V DC -15% ... +15% reverse polarity protected |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV |
Solenoid duty cycle | 100 % |
Safety class | III |
Current consumption | |
ICM | 450 mA Solenoid |
LED | max. 6 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection type | 1 plug connector M12, 8-pin |
Installation orientation | any |
Switching frequency | 1 Hz |
Degree of freedom X | ±5 mm |
Degree of freedom Y | ±5 mm |
Degree of freedom Z | ±4 mm |
Mechanical life | 2 x 10⁶ |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP67 (with screwed tight plug connector) |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Material | |
Safety switch | Die-cast aluminum |
Ramp | Stainless steel |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Guard locking principle | Closed-circuit current principle |
Miscellaneous
C number | |
C2333 | with mounted lockout mechanism |
Tartozékok

AM-C-SW4-V3-161344
- Plastic inserts for hexagon socket screws a/f 4
- Efficient protection against tampering for safety switch mounting
- The packaging includes inserts for 18 screws

AM-C-SW5-V3-161348
- Plastic inserts for hexagon socket screws a/f 5
- Efficient protection against tampering for safety switch mounting
- The packaging includes inserts for 18 screws
Letöltések
Teljes csomag
Minden fontos dokumentum letöltése egyetlen kattintással.
Tartalom:
- A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
- A használati utasítást kiegészítő adatlapok
- A megfelelőségi nyilatkozat
Egyedi dokumentumok



Betriebsanleitung Lesekopf CET-AX mit Zuhaltung und Zuhaltungsüberwachung



Egyéb dokumentumok

Rendelési adatok
Rend. sz. | 111918 |
Cikk neve | CET1-AX-LRA-00-50F-SA-C2333-111918 |
Súly | 1,343kg |
Global Trade Item Number (GTIN) | 4047048006263 |
Vámtarifaszám | 85365019000 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |