EUCHNER – More than safety.
EUCHNER – More than safety.

CES-I-AP-M-C04-USB-117324 (Rend. sz. 117324)

Non-contact safety switches CES-I-AP-.-C04-…, M12

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • Three active faces
  • Connecting cable PUR, 0.22 m, plug connector M12, 5-core
  • Multicode
  • Monitoring output OD
CES-I-AP-M-C04-USB-117324 (Rend. sz. 117324)

Ismertetés

Installation position

Permissible installation position

Multicode evaluation

Every suitable actuator is detected by the switch.

Category according to EN 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4/PL e according to EN 13849-1

Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated.

LED indicator

STATE

Status LED

DIA

Diagnostics LED

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1UBPower supply, DC 24 VBN
2FO1ASafety output, channel 1WH
30 VGround, DC 0 VBU
4FO1BSafety output, channel 2BK
5ODMonitoring outputGY
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
CES-C04: in use

Dimensional drawings

Dimensional drawings
1Active face
2LED status indication
3With rubber support

Connection examples

Connection examples

Műszaki adatok

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E346349_1/1ECOLAB__

Workspace

Repeat accuracy R
according to EN 60947-5-2 <= 10

Electrical connection values

Fuse
external (operating voltage) 0.25 ... 8 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp 1.5 kV
Operating voltage DC
UB 24 V DC -15% ... +15% regulated, residual ripple<5%, PELV (The device tolerates voltage interruptions in the operating voltage, e.g. test pulses, of up to 5 ms. These voltage interruptions are also output on the outputs.)
Turn-on time
Safety outputs max. 300 ms
EMC protection requirements Acc. to EN IEC 60947-5-3
Risk time according to EN 60947-5-3 max. 260 ms
Safety class III
Current consumption
no load on outputs max. 35 mA
Degree of contamination (external, according to EN 60947-1) 3
Monitoring output OD
Output type p-switching, short circuit-proof
Output voltage 0.8 x UB ... UB V DC
Switching current max. 50 mA
Safety outputs FO1A / FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
rated conditional short-circuit current 100 A
Discrepancy time max. 10 ms
Utilization category
DC-13 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Off-state current Ir max. 0.25 mA
Switching current
per safety output 1 ... 150 mA
Test pulse duration max. 0.3 ms (Applies to a load with C<= 30 nF and R<= 20 kohm)
Test pulse interval min. 100 ms

Mechanical values and environment

Connection type PUR cable, 200 mm, with plug connector M12x1, 5-pin
Tightening torque
Fixing screws max. 0.8 Nm
Ready delay 0.5 s
Dynamic bending radius 10 x cable diameter
Static bending radius 5 x cable diameter
Installation orientation any
Switching frequency max. 1 Hz
Mounting distance
between switches min. 80 mm
Mounting type non-flush on metal
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67
Cable ambient temperature (dynamic) -25 ... +65 °C
Cable ambient temperature (static) -25 ... +65 °C
Material
Housing Plastic, PBT
Rubber support NBR 80 ±5 Shore

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionPL e-4.1x10-9420 y


Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures
Additional feature Rubber support included

In combination with actuator CES-A-BBN-C04-115271, CES-A-BBN-C04-EX-137527

Switch-on distance
Installation position C or D (broad side) 11 mm
Installation position A or B (front side) 15 mm
Secured switch-off distance sar
in x/z direction max. 40 mm
in y direction max. 60 mm
Secured switching distance sao
Installation position C or D (broad side) min. 6 mm
Installation position A or B (front side) min. 10 mm
Switching hysteresis 1 ... 2 mm

In combination with actuator CES-A-BDN-06-161742

Switch-on distance
Installation position A 25 mm
Installation position C 20 mm
Secured switch-off distance sar
Installation position C max. 72 mm
Installation position A max. 77 mm
Secured switching distance sao
Installation position C min. 10 mm
Installation position A min. 15 mm
Switching hysteresis 1 ... 2 mm

In combination with actuator CES-A-BDN-06-104730

Switch-on distance
Installation position A or B (front side) 19 mm
Installation position C or D (broad side) 15 mm
Secured switch-off distance sar
in x/z direction max. 40 mm
in y direction max. 60 mm
Secured switching distance sao
Installation position A or B (front side) min. 14 mm
Installation position C or D (broad side) min. 10 mm
Switching hysteresis 1 ... 2 mm

In combination with actuator CES-A-BBN-161502

Switch-on distance
Installation position A + B 25 mm
Installation position C + D 20 mm
Secured switch-off distance sar
in x/z direction / installation position A + B max. 69 mm
in x/z direction / installation position C + D max. 64 mm
in y direction / installation position A + B max. 77 mm
in y direction / installation position C + D max. 72 mm
Secured switching distance sao
in z direction / installation position A + B min. 15 mm
in x direction/installation position C + D min. 10 mm
Switching hysteresis
in z direction / installation position A + B 1 ... 2 mm
in x direction/installation position C + D 1 ... 2 mm

Tartozékok

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 6,8 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 117324
Cikk neve CES-I-AP-M-C04-USB-117324
Súly 0,085kg
Vámtarifaszám 85365019000
ECLASS 27-27-24-03 Safety-related transponder switch

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu

Cookie-értesítés

Műszakilag szükséges sütiket használunk, amelyek a weboldal működéséhez elengedhetetlenek. Ezenkívül statisztikai sütit használunk a weboldalunk használatának elemzésére és kínálatunk folyamatos fejlesztésére. Ön maga döntheti el, hogy beleegyezik-e a statisztikai cookie használatába. További információk az adatvédelmi szabályzatunkban találhatók.