Evaluation module and bus module MGB-L1...-PN... (guard locking by spring force) with 4 control elements, 7/8" and M12 plugs
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850, illuminated
- 3 illuminated pushbuttons with symbol
- Connection via 7/8" and M12 plugs
- Pre-assembled on mounting plates
- Integrated Profinet RT switch
- Unicode
Ismertetés
Profinet connection
7/8" plugs according to ANSI/B93.55M-1981 and M12 plugs (d-coded) according to IEC 61076-2-101
Profinet RT switch
Point-to-point topology network structure due to integrated RT switch.
Flexible use as interlocking or guard locking
By means of the corresponding evaluation of the safe device data by the control system, use can be as either interlocking or guard locking (with or without monitoring).
Illuminated emergency stop
Emergency stop with illumination that can be controlled as required.
Dimensional drawings
Műszaki adatok
Approvals
Workspace
Secured switch-off distance sar | |
Door position | max. 65 mm |
Operating and display elements
Occupancy diagram | |
B1 | |
L0 |
Item | Color | Extras | Switching element | Slide-in label | Note slide-in label | Version | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
90 | white | printed | 1NO | Illuminated pushbutton | |||||
91 | white | printed | 1NO | Illuminated pushbutton | |||||
92 | Green | printed | 1NO | Illuminated pushbutton | |||||
94 | 2 PD | Emergency stop illuminated |
Electrical connection values
Connecting cable | |
Ethernet | Profinet I/O cable, at least cat. 5e |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
maximum feed-in current in the connection block | |
X1, X2 | max. 4000 mA |
Safety class | III |
Current consumption | max. 500 mA |
Transponder coding | Unicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Power supply X1 | |
Fuse | |
external | min. 1 A slow blow |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system) |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Mechanical values and environment
Connection type | |
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e | M12, D-coded, screened (X4 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) |
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e | M12, D-coded, screened (X3 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) |
7/8" Power (X1 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) | |
7/8" Power (X2 (The PROFINET 'Cabling and Interconnection Technology' document from the PNO helps with the correct selection of cables).) | |
Installation orientation | Door hinge DIN right |
Switching frequency | 0.25 Hz |
Mechanical life | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
1 x 10⁶ | |
Response time | |
Guard locking | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Emergency stop / machine stop | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Bolt position | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Door position | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP54 |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Locking force FZh | 2000 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Control of guard locking | PL e | - | 3.91x10-8 | 4 | 20 y |
Monitoring of the guard position | PL e | 3 | 4.07x10-8 | 4 | 20 y |
Monitoring of guard locking | PL e | 3 | 4.07x10-8 | 4 | 20 y |
Evaluating safety signals | PL e | 3 | 4.1x10-8 | 4 | 20 y |
Applies to all additionally included safety functions such as EMERGENCY STOP, enabling switch, etc. |
B10D | Mission time | |
---|---|---|
Emergency stop | 0.13x106 | 20 y |
Miscellaneous
Product version number | V3.30.10 |
Interface
Bus data protocol | Profinet (IEC 61158 type 10) |
Safety data protocol | Profisafe (IEC 61784-3-3) |
Date interface | |
Ethernet |
Tartozékok
Letöltések
Teljes csomag
Minden fontos dokumentum letöltése egyetlen kattintással.
Tartalom:
- A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
- A használati utasítást kiegészítő adatlapok
- A megfelelőségi nyilatkozat
Egyedi dokumentumok
Egyéb dokumentumok
Rendelési adatok
Rend. sz. | 122733 |
Cikk neve | MGB-L1B-PNA-R-122733 |
Súly | 4,kg |
Vámtarifaszám | 85371098 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |