EUCHNER – More than safety.
EUCHNER – More than safety.

MGBS-P-L1HE-AR-U-R-SH-160520 (Rend. sz. 160520)

MGBS set AR, M23, emergency stop, 2 pushbuttons, with escape release, door hinge on right

  • Locking module with handle module
  • suitable for doors hinged on the right
  • Series connection possible (up to 20 AR devices in series)
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • Emergency stop
  • 2 pushbuttons (illuminated)
  • With plug connector M23
  • Unicode
  • Door position monitoring output
  • incl. escape release and inner door handle
MGBS-P-L1HE-AR-U-R-SH-160520 (Rend. sz. 160520)

Ismertetés

Unicode evaluation

Each handle module is highly coded (unicode). The locking module detects only handle modules that have been taught-in. Additional handle modules can be taught-in. Only the last handle module taught-in is detected.

Guard locking type

MGBS-L1

Guard locking actuated by spring force and power-ON released (closed-circuit current principle).

Lens set

The color of the pushbuttons can be selected using the color cover set included (5 colors).

Escape release

It is used for manual release of the guard locking without tools in an emergency. The inner door handle permits escape from the danger zone.

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1IMPSolenoid operating voltage, 24 V DCVT
2FI1AEnable input, channel ARD
3FI1BEnable input, channel BGY
4FO1ASafety output, channel ARD/BU
5FO1BSafety output, channel BGN
6UBElectronics operating voltage, 24 V DCBU
7RSTReset inputGY/PK
8ODDoor position monitoring outputGN/WH
9OIDiagnostic monitoring outputYE/WH
10S1.A1EMERGENCY STOP (channel A)GY/WH
11S1.A2EMERGENCY STOP (channel A)BK
12FEFunctional earth (must be connected to meet the EMC requirements)GN/YE
13S1.B1EMERGENCY STOP (channel B)PK
14S1.B2EMERGENCY STOP (channel B)BN/GY
15S2Pushbutton 2 (illuminated)BN/YE
16H2LED 2BN/GN
17S3Pushbutton 3 (illuminated)WH
18H3LED 3YE
190 VElectronics and solenoid operating voltage, 0 V DCBN
Dimension drawing MGBS set with escape release
Dimension drawing MGBS set with escape release
Wiring diagram
Wiring diagram
MGBS
Multifunctional door locking systems

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Műszaki adatok

Approvals

c_UL_us_E155795_3/11

Escape release AE-R-S1-158322 (Order no. 158322)

Escape release AE-R-S1-158322  (Order no. 158322)

Mechanical values and environment

Installation orientation any
Mechanical life 1 x 10⁶
Ambient temperature -20 ... +55 °C
Material
Housing Die-cast zinc, stainless steel powder-coated, brass

Miscellaneous

Additional feature with silver-colored handle

Handle modules MGBS-H-BA1A3-R-157543 (Order no. 157543)

Handle modules MGBS-H-BA1A3-R-157543  (Order no. 157543)

Mechanical values and environment

Installation orientation Door hinge DIN right
Degree of protection IP65
Ambient temperature -20 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Miscellaneous

Product version number V1.0.0
Additional feature with automatic lockout mechanism

Locking modules MGBS-P-L1-AR-U-R-AEE-SH-159086 (Order no. 159086)

Locking modules MGBS-P-L1-AR-U-R-AEE-SH-159086  (Order no. 159086)

Workspace

Repeat accuracy R
according to EN 60947-5-2 10 %

Operating and display elements

ItemColorExtrasSlide-in labelSwitching elementNote slide-in labelVersionNumberDesignation1LED
12 PDEmergency stop
21NOIlluminated pushbutton
31NOIlluminated pushbutton

Electrical connection values

Fuse
external (operating voltage UB) 0.25 ... 8 A
external (solenoid operating voltage IMP) 0.5 ... 8 A
Power consumption 6 W
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 0.5 kV
Operating voltage DC
UUB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
EMC protection requirements Acc. to EN IEC 60947-5-3
Utilization category
DC-13 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV
Solenoid duty cycle 100 %
Risk time according to EN 60947-5-3 max. 260 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Switching load
according to UL 24V DC, Class 2 (alternatively, see operating instructions)
Safety class
EN IEC 61140 III
Current consumption
IUB 40 mA
IIMP 400 mA
Test pulse duration max. 1.0 ms (Applies to a load with C<= 30 nF and R<= 20 kohm)
Test pulse interval min. 140 ms
Degree of contamination (external, according to EN 60947-1) 3
Controls and indicators
Operating voltage UB V
Operating current 1 ... 50 mA
Power supply
LED 24 V
Current consumption
LED 10 mA
Emergency stop
Breaking capacity max. 0.25 W
Switching voltage 5 ... 24 V
Switching current 1 ... 100 mA
Monitoring output OD, OI
Output type p-switching, short circuit-proof
Output voltage 0.8xUB ... UB V DC
Switching current 1 ... 50 mA
Safety outputs FO1A / FO1B
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage
HIGH U(FO1A) / U(FO1B) UB-1.5 ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Discrepancy time
both safety outputs max. 10 ms Acc. to EN IEC 60947-5-3
Turn-on time max. 400 ms
Off-state current Ir max. 0.25 mA
Switching current
per safety output FO1A / FO1B 1 ... 150 mA

Mechanical values and environment

Approach speed max. 20 m/min
Connection type 1 plug connector M23, 19-pin, RC18
Extraction force 20 N
Ready delay 8 s
Actuating force 10 N
Installation orientation Door hinge DIN right
Switching frequency max. 0.5 Hz
Mechanical life 1 x 10⁶
Overtravel 5 mm
Retention force 20 N
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (screwed tight plug connector/mating component)
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Material
Safety switch housing Reinforced thermoplastic
Switch bracket Die-cast zinc
Locking force Fmax 3900 N
Locking force FZh 3000 N (Fzh = Fmax/1.3, depending on the actuator used)
Guard locking principle Closed-circuit current principle

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions
Additional feature
incl. lens set, ID no. 120344
Escape release actuated by pushing

Tartozékok

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 16,6 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 160520
Cikk neve MGBS-P-L1HE-AR-U-R-SH-160520
Súly 4,661kg
Vámtarifaszám 85371098
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu

Cookie-értesítés

Műszakilag szükséges sütiket használunk, amelyek a weboldal működéséhez elengedhetetlenek. Ezenkívül statisztikai sütit használunk a weboldalunk használatának elemzésére és kínálatunk folyamatos fejlesztésére. Ön maga döntheti el, hogy beleegyezik-e a statisztikai cookie használatába. További információk az adatvédelmi szabályzatunkban találhatók.