MCM-MLI-YE6E6A4A4-PA-163584 (Rend. sz. 163584)

Expansion module MCM-MLI... (2 white covers for indicators, 2 key-operated rotary switches)

  • Function expansion for bus module MBM and locking module MGB2-L.-MLI
  • Four slots for mounting submodules
  • Category 4/PL e for the evaluation of all safety functions
  • 2 white covers for indicators, 2 key-operated rotary switches
  • 2 blanking covers
  • Submodule connection type: N/P
  • Compatible with all Modular devices
MCM-MLI-YE6E6A4A4-PA-163584 (Rend. sz. 163584)

Ismertetés

Function

The MCM Modular can be connected directly or remotely to the bus module and in this way can be operated as a control terminal. It can also be used to extend the control features on a locking module. The MCM Modular offers four slots for mounting submodules.

Expandable via connection on the top

Either a module plug connector or a plug for the direct connection of a signal light with up to four lamps can be used on the top of the MCM.

Dimension drawing
Dimension drawing
MGB2 Modular: at a glance
Multifunctional door locking systems

Dimensional drawings

Dimensional drawings

Műszaki adatok

Approvals

c_UL_us_E155795_3/9

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PFHD 2.82 x 10-9 (Fixed failure rate without consideration of faults in wearing parts)

Submodules MSM-1-N-AA-000-A4-126372 (Order no. 126372)

Submodules MSM-1-N-AA-000-A4-126372  (Order no. 126372)

Mechanical values and environment

Installation orientation any
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Ambient temperature
with UB = 24 V DC -30 ... +55 °C
Material Fiber glass reinforced plastic

Module connector AC-MC-SB-M-A-157024 (Order no. 157024)

Module connector AC-MC-SB-M-A-157024  (Order no. 157024)

Electrical connection values

Connecting cable
MLI 5-pin, M12x1
Rated voltage 36 V
Rated voltage 30 V
Nominal current
at 40 °C 4 A
Degree of contamination according to EN 60664-1 3

Mechanical values and environment

Ambient temperature -30 ... +55 °C
Connection 1
Connection type 2x M4 screws
Connection type Male plug
Number of pins 5
Degree of protection IP65 (Only in the screwed tight state with the related mating components.)
Insertion cycles 100
Material
Plug housing Plastic
Connection 2
Connection type Screw terminal
Connection type Male plug
Type specification M12 EN 61076-2-101 / A-coded
Number of pins 5
Degree of protection IP65 (Only in the screwed tight state with the related mating components.)
Insertion cycles 100
Material
Plug housing Plastic, die-cast zinc, nickel plated
Plug lock die-cast zinc, nickel plated

Control modules MCM-MLI-Y00000000-JJ-157854 (Order no. 157854)

Control modules MCM-MLI-Y00000000-JJ-157854  (Order no. 157854)

Electrical connection values

Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements EMC Directive 2014/30/EU
Safety class III
Current consumption max. 75 mA
Degree of contamination (external, according to EN 60947-1) 3

Mechanical values and environment

Switching frequency 0.25 Hz
Mechanical life 1 x 10⁶
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (This is the case only in the closed state with correctly mounted connecting cables and submodules.)
Ambient temperature
with UB = 24 V DC -25 ... +55 °C
Material
Housing Fiber glass reinforced plastic, die-cast zinc, nickel plated

Submodules MSM-1-P-CA-LQU-E6-163610 (Order no. 163610)

Submodules MSM-1-P-CA-LQU-E6-163610  (Order no. 163610)

Operating and display elements

ItemColorExtrasSwitching elementVersionNote slide-in labelSlide-in labelNumberDesignation1LED
1whiteprinted2NOCover for indicators
217.5x27 mmPosition for slide-in label
3E2Key-operated rotary switch

Electrical connection values

Current consumption max. 12 mA
Controls and indicators
Breaking capacity max. 0.25 W
Switching voltage 24 V
Switching current 5 ... 10 mA
LED power supply 24 V DC

Mechanical values and environment

Installation orientation any
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (IP20) (IP65: only in the screwed tight state with the specified base units.)
Ambient temperature
with UB = 24 V DC -25 ... +55 °C
Material Fiber glass reinforced plastic, die-cast zinc, nickel plated

Miscellaneous

Slide-in label
NumberLabelingNote
1without marking
Software ID (SW ID) 9000018

AC-MC-00-0-B-156718 (Order no. 156718)

AC-MC-00-0-B-156718  (Order no. 156718)

Electrical connection values

Degree of contamination according to EN 60664-1 3

Mechanical values and environment

Ambient temperature -30 ... +55 °C
Material Fiber glass reinforced plastic
Connection 1
Connection type 2x M4 screws
Degree of protection IP65 (Only in the screwed tight state with the specified base units.)

Miscellaneous

Color black
Additional feature
incl. fixing screws
incl. seal

Tartozékok

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 8,3 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 163584
Cikk neve MCM-MLI-YE6E6A4A4-PA-163584
Súly 1,365kg
Vámtarifaszám 85371098
ECLASS 27-24-26-03 Field bus, decentralized peripheral - module carrier

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu

Cookie-értesítés

Műszakilag szükséges sütiket használunk, amelyek a weboldal működéséhez elengedhetetlenek. Ezenkívül statisztikai sütit használunk a weboldalunk használatának elemzésére és kínálatunk folyamatos fejlesztésére. Ön maga döntheti el, hogy beleegyezik-e a statisztikai cookie használatába. További információk az adatvédelmi szabályzatunkban találhatók.