Submodule MSM-1-R... (3 x M12 plug connectors for OSSD safety switches)
- Function expansion for modules MGB2 and MCM
- Connection type: R
- 3 x M12 plug connectors for connecting OSSD safety switches
- Status LED per M12 plug connector
![MSM-1-R-DA-SISISI-H1-165628 (Rend. sz. 165628)](https://assets2.euchner.de/files/41/60/ast_1954160_xl.png)
Ismertetés
Dimensional drawings
![Dimensional drawings](https://assets2.euchner.de/files/18/30/ast_1951830.png)
1 | Coding alignment |
2 | Red built-in socket |
LED1 | LED indicator |
LED2 | LED indicator |
LED3 | LED indicator |
Pos 1 | M12 plug connector for connecting an OSSD safety switch |
Pos 2 | M12 plug connector for connecting an OSSD safety switch |
Pos 3 | M12 plug connector for connecting an OSSD safety switch |
Z | marks position of Item 1 |
Dimensional drawings
![Dimensional drawings](https://assets2.euchner.de/files/30/85/ast_643085.png)
Műszaki adatok
Operating and display elements
Item | Color | Extras | Slide-in label | Version | Note slide-in label | Switching element | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
1 | Connection M12x1 for OSSD device | ||||||||
2 | Connection M12x1 for OSSD device | ||||||||
3 | Connection M12x1 for OSSD device |
Electrical connection values
Current consumption | max. 50 mA |
Controls and indicators | |
Breaking capacity | max. 0.25 W |
Switching voltage | 24 V |
Switching current | 5 ... 10 mA |
Mechanical values and environment
Installation orientation | any |
Response time | See operating instructions for bus module MBM-... or interlocking/locking module MGB2-I.-BR-... / MGB2-L.-BR-... |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65 (IP20) (IP65: only in the screwed tight state with the specified base units.) |
Ambient temperature | |
at UB = 24 V DC | -25 ... +55 °C |
Material | Fiber glass reinforced plastic, die-cast zinc, nickel plated |
Miscellaneous
Software ID (SW ID) | 165628 |
Tartozékok
CES-AP
Non-contact safety switch CES-AP-C01-...
![CES-AP-C01-CH-SB-106798](https://assets2.euchner.de/files/63/40/ast_736340_xs.png)
106798
CES-AP-C01-CH-SB-106798
CES-AP-C01-CH-SB-106798
- Safety switch with integrated evaluation electronics
- No series connection
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- M12 plug connector 5-pin
- Multicode
![CES-AP-C01-CH-SB-111708](https://assets2.euchner.de/files/63/40/ast_736340_xs.png)
111708
CES-AP-C01-CH-SB-111708
CES-AP-C01-CH-SB-111708
- Safety switch with integrated evaluation electronics
- No series connection
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- M12 plug connector 5-pin; pin 5 not used
- Multicode
![CES-AP-C01-AH-SB-111145](https://assets2.euchner.de/files/63/40/ast_736340_xs.png)
111145
CES-AP-C01-AH-SB-111145
CES-AP-C01-AH-SB-111145
- Safety switch with integrated evaluation electronics
- No series connection
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- M12 plug connector 5-pin; pin 5 not used
- Unicode
Non-contact safety switch CES-AP-CL2-... , M12; pin 5 not used, PUR
![CES-AP-CL2-CH-SB-109167](https://assets2.euchner.de/files/70/58/ast_737058_xs.png)
109167
CES-AP-CL2-CH-SB-109167
CES-AP-CL2-CH-SB-109167
- Safety switch with integrated evaluation electronics
- No series connection
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Door hinge left
- Category 4 / PL e according to EN ISO 13849-1
- Connecting cable PUR, 0.2 m, plug connector M12, 5-pin; pin 5 not used
- Multicode
- Two safety screws M4x14 included
![CES-AP-CL2-AH-SB-111747](https://assets2.euchner.de/files/70/58/ast_737058_xs.png)
111747
CES-AP-CL2-AH-SB-111747
CES-AP-CL2-AH-SB-111747
- Safety switch with integrated evaluation electronics
- No series connection
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Door hinge left
- Category 4 / PL e according to EN ISO 13849-1
- Connecting cable PUR, 0.2 m, plug connector M12, 5-pin; pin 5 not used
- Unicode
- Two safety screws M4x14 included
Non-contact safety switch CES-AP-CR2-... , M12; pin 5 not used, PUR
![CES-AP-CR2-CH-SB-109168](https://assets2.euchner.de/files/70/58/ast_737058_xs.png)
109168
CES-AP-CR2-CH-SB-109168
CES-AP-CR2-CH-SB-109168
- Safety switch with integrated evaluation electronics
- No series connection
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Door hinge right
- Category 4 / PL e according to EN ISO 13849-1
- Connecting cable PUR, 0.2 m, plug connector M12, 5-pin; pin 5 not used
- Multicode
- Two safety screws M4x14 included
![CES-AP-CR2-AH-SB-111748](https://assets2.euchner.de/files/70/58/ast_737058_xs.png)
111748
CES-AP-CR2-AH-SB-111748
CES-AP-CR2-AH-SB-111748
- Safety switch with integrated evaluation electronics
- No series connection
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Door hinge right
- Category 4 / PL e according to EN ISO 13849-1
- Connecting cable PUR, 0.2 m, plug connector M12, 5-pin; pin 5 not used
- Unicode
- Two safety screws M4x14 included
Non-contact safety switches CES-I-AP-.-C04-, M12; pin 5 not used
![CES-I-AP-U-C04-USI-115150](https://assets2.euchner.de/files/70/59/ast_737059_xs.png)
115150
CES-I-AP-U-C04-USI-115150
CES-I-AP-U-C04-USI-115150
- Safety switch with integrated evaluation electronics
- No series connection
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces
- Connecting cable PUR, 0.1 m, plug connector M12, 5-pin; pin 5 not used
- Unicode
![CES-I-AP-M-C04-USI-117323](https://assets2.euchner.de/files/70/59/ast_737059_xs.png)
117323
CES-I-AP-M-C04-USI-117323
CES-I-AP-M-C04-USI-117323
- Safety switch with integrated evaluation electronics
- No series connection
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces
- Connecting cable PUR, 0.1 m, plug connector M12, 5-pin; pin 5 not used
- Multicode
![CES-I-AP-M-C04-USI-160832](https://assets2.euchner.de/files/70/59/ast_737059_xs.png)
160832
CES-I-AP-M-C04-USI-160832
CES-I-AP-M-C04-USI-160832
- Safety switch with integrated evaluation electronics
- No series connection
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces
- Connecting cable PUR, 1.5 m, plug connector M12, 5-pin; pin 5 not used
- Multicode
![CES-I-AP-M-C04-USI-162592](https://assets2.euchner.de/files/70/59/ast_737059_xs.png)
162592
CES-I-AP-M-C04-USI-162592
CES-I-AP-M-C04-USI-162592
- Safety switch with integrated evaluation electronics
- No series connection
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces
- Connecting cable PUR, 2 m, plug connector M12, 5-pin; pin 5 not used
- Multicode
Non-contact safety switches CES-I-AP-.-C04-…, M12
![CES-I-AP-U-C04-USB-116502](https://assets2.euchner.de/files/70/59/ast_737059_xs.png)
116502
CES-I-AP-U-C04-USB-116502
CES-I-AP-U-C04-USB-116502
- Safety switch with integrated evaluation electronics
- No series connection
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces
- Connecting cable PUR, 0.22 m, plug connector M12, 5-core
- Unicode
- Monitoring output OD
![CES-I-AP-M-C04-USB-117324](https://assets2.euchner.de/files/70/59/ast_737059_xs.png)
117324
CES-I-AP-M-C04-USB-117324
CES-I-AP-M-C04-USB-117324
- Safety switch with integrated evaluation electronics
- No series connection
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces
- Connecting cable PUR, 0.22 m, plug connector M12, 5-core
- Multicode
- Monitoring output OD
CES-FD
Field evaluation unit CES-FD-AP-…
![CES-FD-AP-M-01-USI-115534](https://assets2.euchner.de/files/63/37/ast_736337_xs.png)
115534
CES-FD-AP-M-01-USI-115534
CES-FD-AP-M-01-USI-115534
- Connection of a CES/CKS read head
- Evaluation of signals in the field
- Connection to the ET200s and ET200pro
- Familiar EUCHNER AP interface
- Multicode
![CES-FD-AP-U-01-USI-119865](https://assets2.euchner.de/files/63/37/ast_736337_xs.png)
119865
CES-FD-AP-U-01-USI-119865
CES-FD-AP-U-01-USI-119865
- Connection of a CES/CKS read head
- Evaluation of signals in the field
- Connection to the ET200s and ET200pro
- Familiar EUCHNER AP interface
- Unicode
CES-I-BP
Non-contact safety switches CES-I-BP-.-C07, M12
![CES-I-BP-M-C07-SB-160076](https://assets2.euchner.de/files/70/21/ast_737021_xs.png)
160076
CES-I-BP-M-C07-SB-160076
CES-I-BP-M-C07-SB-160076
- Safety switch with integrated evaluation electronics
- Suitable for separate operation (no series connection)
- Multicode
- M12 plug connector, 5-pin
- With door monitoring output OD
- Diagnostics via IO-Link with safety module ESM-CB
- 2 safety outputs (semiconductor outputs)
- Short circuit monitoring
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces
![CES-I-BP-U-C07-SB-160080](https://assets2.euchner.de/files/70/21/ast_737021_xs.png)
160080
CES-I-BP-U-C07-SB-160080
CES-I-BP-U-C07-SB-160080
- Safety switch with integrated evaluation electronics
- Suitable for separate operation (no series connection)
- Unicode
- M12 plug connector, 5-pin
- With door monitoring output OD
- Diagnostics via IO-Link with safety module ESM-CB
- 2 safety outputs (semiconductor outputs)
- Short circuit monitoring
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces
![CES-I-BP-M-C07-SI-162813](https://assets2.euchner.de/files/70/21/ast_737021_xs.png)
162813
CES-I-BP-M-C07-SI-162813
CES-I-BP-M-C07-SI-162813
- Safety switch with integrated evaluation electronics
- Suitable for separate operation (no series connection)
- Multicode
- M12 plug connector, 5-pin (pin 5 not used)
- Direct connection to IP67 field modules
- 2 safety outputs (semiconductor outputs)
- Short circuit monitoring
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces
![CES-I-BP-U-C07-SI-162815](https://assets2.euchner.de/files/70/21/ast_737021_xs.png)
162815
CES-I-BP-U-C07-SI-162815
CES-I-BP-U-C07-SI-162815
- Safety switch with integrated evaluation electronics
- Suitable for separate operation (no series connection)
- Unicode
- M12 plug connector, 5-pin (pin 5 not used)
- Direct connection to IP67 field modules
- 2 safety outputs (semiconductor outputs)
- Short circuit monitoring
- Category 4 / PL e according to EN ISO 13849-1
- Three active faces
Letöltések
Teljes csomag
Minden fontos dokumentum letöltése egyetlen kattintással.
Tartalom:
- A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
- A használati utasítást kiegészítő adatlapok
- A megfelelőségi nyilatkozat
Declarations of conformity
UKCA-Konformitätserklärung
Dok. sz.
Változat
Nyelv
Méret
![Dok. sz. EDC20001508](https://assets2.euchner.de/files/61/69/ast_2636169_thumb.jpg)
UKCA-Konformitätserklärung
Dok. sz.
EDC20001508
Változat
Nyelv
Méret
0,1 MB
Instructions
Operating Instructions Submodule MSM-1-R-.A-…
Dok. sz.
Változat
Nyelv
Méret
![Dok. sz. 2539735](https://assets2.euchner.de/files/43/82/ast_2604382_thumb.jpg)
Operating Instructions Submodule MSM-1-R-.A-…
Dok. sz.
2539735
Változat
12/22
Nyelv
Méret
1,1 MB
![Dok. sz. 2539735](https://assets2.euchner.de/files/43/84/ast_2604384_thumb.jpg)
Mode d’emploi Sous-module MSM-1-R-.A-…
Dok. sz.
2539735
Változat
12/22
Nyelv
Méret
1,1 MB
![Dok. sz. 2539735](https://assets2.euchner.de/files/43/83/ast_2604383_thumb.jpg)
Manual de instrucciones Submódulo MSM-1-R-.A-…
Dok. sz.
2539735
Változat
12/22
Nyelv
Méret
1,1 MB
![Dok. sz. 2539735](https://assets2.euchner.de/files/34/87/ast_2603487_thumb.jpg)
Betriebsanleitung Submodul MSM-1-R-.A-…
Dok. sz.
2539735
Változat
12/22
Nyelv
Méret
1,1 MB
CAD-adatok
Rendelési adatok
Rend. sz. | 165628 |
Cikk neve | MSM-1-R-DA-SISISI-H1-165628 |
Súly | 0,125kg |
Vámtarifaszám | 85371098 |
ECLASS | 27-24-26-05 Field bus, decentralized peripheral - function-/technology module |