EUCHNER – More than safety.
EUCHNER – More than safety.

CES-FD-AP-U-01-USI-166446 (Rend. sz. 166446)

Field evaluation unit CES-FD-AP-…

  • connection of a CES/CKS read head
  • Evaluation of signals in the field
  • EUCHNER AP interface
  • Suitable for separate operation (no series connection)
  • Unicode
  • Direct connection to IP67 field modules (e.g. ET200pro)
  • Connecting cables PUR, with plug connector: - M8 angled / 3-pin (read head connection) - M12 straight / 5-pin (AP interface)
CES-FD-AP-U-01-USI-166446 (Rend. sz. 166446)

Ismertetés

Short circuit monitoring

The switch generates its own clock signal on the output lines FO1A/FO1B. Pay attention to this aspect when connecting to control systems and relays.

Category according to EN ISO 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN ISO 13849-1

Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must always be evaluated.

LED indicator

STATE

Status LED

DIA

Diagnostics LED

Connection for control system

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1UBPower supply, DC 24 VBN
2FO1ASafety output, channel 1WH
30 VGround, DC 0 VBU
4FO1BSafety output, channel 2BK
5-n.c.GY

Connection for read head

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1H1Data lineBN
3H2Data lineWH
4SHShield-
Dimension drawing
Dimension drawing

Dimensional drawings

Dimensional drawings
1LED status indication
2Coding lug

Műszaki adatok

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E346349_1/1

Workspace

Repeat accuracy R
according to EN 60947-5-2 <= 10

Electrical connection values

Fuse
external (operating voltage) 0.25 ... 8 A
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 1.5 kV
Operating voltage DC
UB (PELV, see operating instructions) (reverse polarity protected, regulated, residual ripple<5%) 24 V DC -15% ... +15% (The device tolerates voltage interruptions in the operating voltage, e.g. test pulses, of up to 5 ms. These voltage interruptions are also output on the safety outputs.)
Turn-on time
Safety outputs max. 400 ms
EMC protection requirements Acc. to EN IEC 60947-5-3
Risk time according to EN 60947-5-3 max. 260 ms
Safety class III
Current consumption max. 45 mA
Degree of contamination (external, according to EN 60947-1) 3
Safety outputs FO1A / FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
rated conditional short-circuit current 100 A
Discrepancy time max. 10 ms
Utilization category
DC-13 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Off-state current Ir max. 0.25 mA
Switching current
per safety output 1 ... 150 mA
Test pulse duration max. 0.3 ms (Applies to a load with C<= 30 nF and R<= 20 kohm)
Test pulse interval min. 100 ms

Mechanical values and environment

Connection type Connecting cable PUR with plug connector M12, 5-pin; pin 5 not used
Tightening torque max. 1 Nm
Ready delay 1 s
Installation orientation any
Switching frequency max. 1 Hz
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65/IP67
Cable ambient temperature (dynamic) -5 ... +65 °C
Cable ambient temperature (static) -20 ... +65 °C
Material
Housing Plastic, PBT

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
Monitoring of the guard position
Category 4
Performance Level PL e
PFHD 4.5 x 10-9

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures

In combination with read head CES-A-LMN-SC and actuator CES-A-BMB

Switch-on distance 5 mm (With read head CES-A-LMN-SC and actuator CES-A-BMB)
Secured switch-off distance sar max. 10 mm (With read head CES-A-LMN-SC and actuator CES-A-BMB)
Secured switching distance sao min. 3.4 mm (With read head CES-A-LMN-SC and actuator CES-A-BMB)
Switching hysteresis 0.05 ... 0.2 mm (With read head CES-A-LMN-SC and actuator CES-A-BMB)

Tartozékok

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 1,9 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 166446
Cikk neve CES-FD-AP-U-01-USI-166446
Súly 0,85kg
Vámtarifaszám 85365019
ECLASS 27-27-24-03 Safety-related transponder switch

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu

Cookie-értesítés

Műszakilag szükséges sütiket használunk, amelyek a weboldal működéséhez elengedhetetlenek. Ezenkívül statisztikai sütit használunk a weboldalunk használatának elemzésére és kínálatunk folyamatos fejlesztésére. Ön maga döntheti el, hogy beleegyezik-e a statisztikai cookie használatába. További információk az adatvédelmi szabályzatunkban találhatók.