CTM-C2-BP-HC-FLX-AZ-SA-170491 (Rend. sz. 170491)

Transponder-coded safety switch CTM-C2-BP, M12

  • Guard locking suitable for process protection only
  • Open-circuit current principle
  • Category 4 / PL e according to EN ISO 13849-1
  • Actuation/extension/retention force: 20/18/5 N
  • Plug connector M12, 8-pin
  • Auxiliary release
  • High coding level
  • FlexFunction device
CTM-C2-BP-HC-FLX-AZ-SA-170491 (Rend. sz. 170491)

Ismertetés

Highly coded evaluation

Each actuator is highly coded (HC). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.

Guard locking type

CTM‑C2

Guard locking actuated by power ON and released by spring force (open-circuit current principle)

FlexFunction

The actuator configures the switch on setup. Depending on the actuator selected, guard lock monitoring of the safety switch is active or inactive.

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1IMPSolenoid control input 24 V DCWH
2UBElectronics and solenoid operating voltage, 24 V DCBN
3FO1ASafety output, channel AGN
4FO1BSafety output, channel BYE
5OIDiagnostic monitoring outputGY
6OD/CDoor position monitoring output/communicationPK
7OLGuard lock monitoring outputBU
80VUBElectronics and solenoid operating voltage, 0 V DCRD
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1LEDs
2Active read head face
3Auxiliary release

Connection examples

Connection examples

Műszaki adatok

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/11

Workspace

Repeat accuracy R
according to EN 60947-5-2 10 %

Electrical connection values

Fuse
external (operating voltage UB) 0.7 ... 8 A
Power consumption
at max. switching frequency 3 W
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 0.5 kV
Discrepancy time
both safety outputs max. 10 ms Acc. to EN 60947-5-3
Einschaltzeit
I-configuration (guard lock monitoring inactive) max. 100 ms
L configuration (guard lock monitoring active) max. 500 ms
Solenoid duty cycle 100 %
Off-state current Ir max. 0.25 mA
Risk time according to EN 60947-5-3 max. 200 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 10 ms
Switching load DC 24V, UL Class 2 (alternatively, see operating instructions)
Safety class III
Test pulse duration max. 0.3 ms
Test pulse interval 100 ms
Degree of contamination (external, according to EN 60947-1) 3
Solenoid IMP
Input voltage
Guard locking active (closed) 20.4 ... 26.4 V DC
Guard locking not active (open) 0 ... 5 V DC
Current consumption
Guard locking active (closed) 20 ... 50 mA
Diagnostic monitoring output OI, door position monitoring output/communication OD/C, guard lock monitoring output OL
Output type p-switching, short circuit-proof
Output voltage 0.8xUB ... UB V DC
Switching current 1 ... 50 mA
Safety outputs FO1A / FO1B
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage
HIGH U(FO1A) / U(FO1B) UB-1.5 ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Discrepancy time
both safety outputs max. 10 ms Acc. to EN 60947-5-3
Turn-on time max. 400 ms
Utilization category
DC-13 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Off-state current Ir max. 0.25 mA
Risk time according to EN 60947-5-3
Single device max. 200 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 10 ms
Electrical switching frequency max. 0.25 Hz
Switching current
per safety output FO1A / FO1B 1 ... 150 mA
Test pulse duration max. 0.3 ms (Applies to a load with C<= 30 nF and R<= 20 kohm)
Test pulse interval 100 ms
Operating voltage UB
Operating voltage DC
UUB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
Current consumption
IUB at operating voltage UB = 24 V max. 500 mA

Mechanical values and environment

Approach speed max. 20 m/min
Connection type Plug connector M12, 8-pin
Extraction force 18 N
Ready delay 5.5 s
Actuating force 20 N
Installation orientation any
Switching frequency max. 0.25 Hz
Mechanical life 1 x 10⁶
Overtravel 2 mm
Retention force 5 N
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65/IP67 (When inserted and secured)
Ambient temperature
with UB = 24 V DC -20 ... +60 °C
Material
Seals Fluorinated rubber (FKM)
Safety switch housing Reinforced thermoplastic
Locking force Fmax 1300 N
Locking force FZh 1000 N
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionPL e34.11x10-9420 y


Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Tartozékok

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 4,2 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 170491
Cikk neve CTM-C2-BP-HC-FLX-AZ-SA-170491
Súly 0,26kg
Vámtarifaszám 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu

Cookie-értesítés

Műszakilag szükséges sütiket használunk, amelyek a weboldal működéséhez elengedhetetlenek. Ezenkívül statisztikai sütit használunk a weboldalunk használatának elemzésére és kínálatunk folyamatos fejlesztésére. Ön maga döntheti el, hogy beleegyezik-e a statisztikai cookie használatába. További információk az adatvédelmi szabályzatunkban találhatók.