EUCHNER – More than safety.
EUCHNER – More than safety.

CES-FD-AS2A-U-01-U002-172238 (Rend. sz. 172238)

Field evaluation unit CES-FD-AS2A with ASi connection

  • Connection of a CES read head or CKS Electronic-Key adapter via M8 plug connector(s)
  • Evaluation of transponder data
  • Integrated ASi connection, permanently connected PUR cable
  • Unicode
  • Highest safety at category 4 / PL e according to EN ISO 13849-1
CES-FD-AS2A-U-01-U002-172238 (Rend. sz. 172238)

Ismertetés

Unicode evaluation

Each actuator/key contains a transponder with a high coding level in accordance with EN ISO 14119. The evaluation unit only recognizes taught-in actuators. Further actuators can be taught-in. Only the last actuator learned is recognized.

AS-Interface

ASi-3 protocol
PUR connection cable, connecting cable with flying lead, 2-wire

AS-Interface inputs

D0, D1, D2, D3 Detection of actuators/keys
Evaluation takes place via a safety monitor

LED function display

The STATE LED indicates the status of the switch
The DIA LED indicates whether an error has been detected in the switch

Dimension drawing
Dimension drawing

Dimensional drawings

Dimensional drawings
1LED status indication
2Cable end sleeve

Műszaki adatok

Electrical connection values

ASI data in
according to AS-Interface Safety ta Work D0 - D3 (Key / actuator detection)
ASI slave type
min. EA code: 0
max. ID code: B
ASI voltage
DC 19 ... 31.6 V
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp 1.5 kV
Turn-on time
Safety outputs max. 300 ms
Risk time according to EN 60947-5-3 max. 260 ms
Safety class III
Current consumption
total max. 50 mA
Degree of contamination (external, according to EN 60947-1) 3

Mechanical values and environment

Connection type
Read head PUR connection cable, connecting cable with flying lead, 2-core
Evaluation Connection cable, connecting cable PUR with plug connector(s) M8X1 3-pin
Ready delay 0.5 s
Installation orientation any
Switching frequency max. 1 Hz
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65/IP67
Cable ambient temperature (dynamic) -5 ... +65 °C
Cable ambient temperature (static) -20 ... +55 °C
Material
Housing Plastic, PBT

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionLesekopf CES-A-LMNPL e-4.5x10-9420 y
Safe key detectionLesekopf CKS-A-L..PL e-4.5x10-9320 y


Miscellaneous

The following applies to the approval according to UL Mode only with UL Class 2 power supply

Tartozékok

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 2,2 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 172238
Cikk neve CES-FD-AS2A-U-01-U002-172238
Súly 0,kg
Vámtarifaszám 85365019000
ECLASS 27-27-24-03 Safety-related transponder switch

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu

Cookie-értesítés

Műszakilag szükséges sütiket használunk, amelyek a weboldal működéséhez elengedhetetlenek. Ezenkívül statisztikai sütit használunk a weboldalunk használatának elemzésére és kínálatunk folyamatos fejlesztésére. Ön maga döntheti el, hogy beleegyezik-e a statisztikai cookie használatába. További információk az adatvédelmi szabályzatunkban találhatók.