Safety switch STM Pro, cable entry M20 x 1.5
- Actuating head made of plastic
- Auxiliary release
- LED indicator
- Cable entry M20 x 1.5
- Closed-circuit current principle

Ismertetés
Guard locking principle
closed-circuit current (power to unlock): In a safety guard with guard locking according to the closed-circuit current principle, the guard is locked by spring force until the guard locking solenoid is supplied with current. The guard is unlocked by means of magnetic force. This is also referred to as mechanical guard locking.
LED indicator
The LED indicator illuminates when voltage is applied to the guard locking solenoid.
Switching element
2222 | Slow-action switching contact |
Contacts for guard locking: 2 positively driven, positively driven contacts | |
Contacts for door monitoring: 2 positively driven, positively driven contacts |
Auxiliary release
The auxiliary release on the front allows access to the machine in the event of a malfunction, e.g. a power failure. It is unlocked using a tool or a key. The auxiliary release must be secured against misuse (sealing, laking).
Scope of delivery
Cable gland included in the scope of delivery.
Required accessories
Actuator is not included in the scope of delivery.
Functional drawings

Dimensional drawings

1 | M5 screw for fixed positioning in safety applications |
2 | LED |
3 | Insertion depth |
4 | Protection against twisting (M4 screw) |
5 | Auxiliary release |
6 | Actuator S standard |
7 | Locking screw (M = 0.5 Nm) |
8 | cable gland |
9 | cable diameter |
Connection examples

Műszaki adatok
Approvals

Electrical connection values
Power consumption | 6 W |
Connection cross section | 0.34 ... 1.5 mm² |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2.5 kV |
Utilization category | |
AC-15 | 4 A 24 V |
DC-13 | 4 A 24 V |
Short circuit protection according to IEC 60269-1 | 4A gG |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Solenoid duty cycle | 100 % |
Switching voltage | |
min. at 10 mA | 12 V |
Switching current | |
min. at 24 V | 1 mA |
thermal rated current Ith | 4 A |
Mechanical values and environment
Approach speed | max. 20 m/min |
Approach direction | B |
Connection type | |
1 x | M20 x 1.5 |
Number of door position positively driven contacts | 2 |
Number of guard lock monitoring positively driven contacts | 2 |
Extraction force | 30 N |
Actuation frequency | max. 1200 1/h |
Actuating force | 35 N |
Installation orientation | any |
Insertion depth | 24.5 mm |
Mechanical life | 2 x 10⁶ |
Retention force | 20 N |
Switching principle | Slow-action switching contact |
Degree of protection | IP67 |
Ambient temperature | -20 ... +55 °C |
Material | |
Contact | Silver alloy, gold flashed |
Housing | Reinforced thermoplastic |
Locking force Fmax | 1000 N |
Locking force FZh | 700 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
B10D | Mission time | |
---|---|---|
Monitoring of the guard position | 2x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V | ||
Monitoring of guard locking | 2x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V |
PL | Maximum SIL | Category | Mission time | |
---|---|---|---|---|
Control of guard locking | Depending on external control of guard locking | 20 y |
In combination with actuator ACTUATOR-S-GT-SN
Overtravel | 5 mm |
Tartozékok
Letöltések
Teljes csomag
Minden fontos dokumentum letöltése egyetlen kattintással.
Tartalom:
- A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
- A használati utasítást kiegészítő adatlapok
- A megfelelőségi nyilatkozat
Egyedi dokumentumok

Déclaration UE de conformité
Declaración de conformidad UE
EU-Konformitätserklärung
Dichiarazione UE di conformità

Déclaration UE de conformité
Declaración de conformidad UE
EU-Konformitätserklärung
Dichiarazione UE di conformità






Egyéb dokumentumok








Rendelési adatok
Rend. sz. | 172827 |
Cikk neve | STM1N-2222B024-L01-M-172827 |
Súly | 0,kg |
Vámtarifaszám | 85365019000 |
ECLASS | 27-27-26-03 Safety switch with guard control |