Interlocking modules MGBS-P-I-AP
- Safety system without guard locking with interlocking function
- Several functions in one solution: door handle, safety door protection, door stop, lockout mechanism
- Optionally with control elements, emergency stop device and escape release
- Safety category 4 and PL e according to EN ISO 13849-1
- Integrated AP electronics
- A special evaluation unit is not required
- Suitable for doors hinged on the right or left and for sliding doors
MGBS - a strong team
Why not combine the best features from different products? Take a CTP transponder-coded safety switch, mount it on a sturdy sub plate, combine everything with an MGB handle module, and what you get is a compact safety door protection device: the new MGBS. This is the ideal solution wherever a slimline switch housing is advantageous, such as on safety fence corner posts. Concealed mounting holes in the handle module and interlocking module provide excellent protection against tampering. A lockout mechanism is included in the handle module. This prevents the installation from starting, e.g. during maintenance and cleaning work. A simple plug connection reduces wiring work. The system is optionally available with an emergency stop device and with controls and indicators. The resulting MGBS is a slimline safety door protection device with the properties of an MGB. Thanks to the transponder technology, the system achieves category 4/PL e according to EN ISO 13849-1, without additional fault exclusion. It complies with all the requirements of EN ISO 14119.Termékek (2)
Nem található eredmény
162586
MGBS-P-I-AP-U-R-ZZ-SA-162586
MGBS-P-I-AP, M12
MGBS-P-I-AP-U-R-ZZ-SA-162586
MGBS-P-I-AP, M12
- Interlocking module without guard locking (order handle module separately)
- Adjustable door hinge; factory setting: right
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4 / PL e according to EN ISO 13849-1
- With plug connector M12
- Unicode
- Door position monitoring output
162926
MGBS-P-I-AP-U-R-ZZE-SBB-162926
MGBS-P-I-AP, emergency stop, 2 x M12
MGBS-P-I-AP-U-R-ZZE-SBB-162926
MGBS-P-I-AP, emergency stop, 2 x M12
- Interlocking module without guard locking (order handle module separately)
- Adjustable door hinge; factory setting: right
- Direct connection to decentralized peripheral systems (e.g. ET200pro)
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4 / PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Unicode
- Emergency stop