Read/write head CIT3 G05 with serial interface
- Serial interface RS232
- Active face can be adjusted to 5 different positions
- Standard housing according to EN 50041
- Connection terminals
Ismertetés
Serial interface
The individual commands for reading and writing the data carrier are in accordance with the common 3964R protocol and are described in the EUCHNER CIS3 system manual (order no. 071 652). For data carrier programming away from the system, a convenient WINDOWS®-compatible PC software application is available (Transponder Coding software, see page 41).
Standard housing
The size of the robust housing in degree of protection IP65 is compliant with the standard EN 50041. The division into 3 assemblies permits easy mounting and straightforward replacement.
Mounting instructions
On mounting the read/write head and data carrier, it is to be ensured the crossing direction as per the direction of the arrow on the active face of the read/write head is observed.
Attention:
On the use of a screened cable the connecting cable for the serial interface is allowed to be max. 5 m long.
Dimensional drawings
1 | Active face |
2 | Crossing direction |
3 | LED status indication |
4 | Shield spring |
m | Center offset |
s | Read distance |
Connection examples
Műszaki adatok
Approvals
Operating and display elements
LED display | |
Green | operational |
Yellow | Data carrier in actuating range |
Electrical connection values
Operating voltage DC | 20 ... 24 ... 28 V DC (All the electrical connections must either be isolated from the mains supply by a safety transformer according IEC/ EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.) |
Current consumption | max. 140 mA |
Mechanical values and environment
Connection type | Screw terminal |
Cable length | max. 5 m for RS232 |
Degree of protection | IP65 |
Ambient temperature | 0 ... +55 °C |
Material | |
Housing | Plastic |
Interface
Data protocol | 3964R via RS232 8 data bits, even parity |
Data rate | 9,6 kbit/s |
Date interface | RS232 |
In combination with data carrier CIS3P16D08KH16YSNOU, CIS3P16D08KH16YSNOP
Read distance | 0 ... 5 ... 14 mm |
Center offset | |
at 25 °C, read distance s=5 mm, in X direction | -10 ... 10 mm |
at 25 °C, read distance s=5 mm, in Y direction | -6 ... 6 mm |
Write distance | |
at 25 °C | 0 ... 5 ... 9 mm |
In combination with data carrier CIS3P35X16SH16YHNOU, CIS3P35X16SH16YHNOP, CIS3P35X16SH16YVNOU, CIS3P35X16SH16YVNOP
Read distance | |
at 25 °C | 0 ... 7 ... 18 mm |
Center offset | |
at 25 °C, read distance s=5 mm, in Y direction | -8 ... 8 mm |
at 25 °C, read distance s=5 mm, in X direction | -10 ... 10 mm |
Write distance | |
at 25 °C | 0 ... 5 ... 10 mm |
Tartozékok
Letöltések
Teljes csomag
Minden fontos dokumentum letöltése egyetlen kattintással.
Tartalom:
- A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
- A használati utasítást kiegészítő adatlapok
- A megfelelőségi nyilatkozat
Egyedi dokumentumok
Egyéb dokumentumok
Rendelési adatok
Rend. sz. | 096560 |
Cikk neve | CIT3SX1R1G05KX |
Súly | 0,372kg |
Vámtarifaszám | 85389099990 |
ECLASS | 27-28-04-01 Identification, RFID Reader |