Locking set MGB-L1...-EI (guard locking by spring force) with 3 pushbuttons, emergency stop and key-operated rotary switch
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850
- 3 illuminated pushbuttons
- OM.R key-operated rotary switch (2-channel)
- Connection via M12 plug
- Pre-assembled on mounting plates
- Integrated switch
- With escape release
- Unicode
Ismertetés
Ethernet/IP connection
M12 plug (a-coded) 4-pin according to IEC 61076-2-101
Integrated switch
Point-to-point topology network structure due to integrated switch.
Flexible use as interlocking or guard locking
By means of the corresponding evaluation of the safe device data by the control system, use can be as either interlocking or guard locking (with or without monitoring).
Escape release
The escape release enables people shut in to open the guard locked door from the danger zone.
Dimensional drawings
Connection examples
Connection examples
Műszaki adatok
Approvals
Escape release MGB-E-A2-106051 (Order no. 106051)
Mechanical values and environment
Installation orientation | any |
Mechanical life | 1 x 10⁶ |
Ambient temperature | -30 ... +55 °C |
Material | |
Housing | Die-cast zinc/stainless steel, powder-coated |
Miscellaneous
Product version number | V2.0.0 |
Additional feature | with mounting plate |
Handle modules MGB-H-AA1A6-L-111839 (Order no. 111839)
Mechanical values and environment
Installation orientation | Door hinge DIN left |
Degree of protection | IP65 |
Ambient temperature | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Miscellaneous
Product version number | V3.0.0 |
Additional feature | with mounting plate and automatic lockout mechanism |
Locking modules MGB-L1B-EIA-L-136485 (Order no. 136485)
Workspace
Secured switch-off distance sar | |
Door position | max. 65 mm |
Operating and display elements
Occupancy diagram | |
B1 | |
L1 |
Item | Color | Extras | Switching element | Slide-in label | Note slide-in label | Version | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
1 | 2 PD | Emergency stop | |||||||
2 | white | printed | 1NO | Illuminated pushbutton | |||||
3 | Red | 1NO | Illuminated pushbutton | ||||||
4 | Green | printed | 1NO | Illuminated pushbutton | |||||
91 | OM.R | 2NO | Key-operated rotary switch |
Electrical connection values
Connecting cable | |
Ethernet | Ethernet/IP cable, at least cat. 5e |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
maximum feed-in current in the connection block | |
X1, X2 | max. 4000 mA |
Safety class | III |
Current consumption | max. 500 mA |
Transponder coding | Unicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Power supply X1 | |
Fuse | |
external | min. 1 A slow blow |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system) |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Mechanical values and environment
Connection type | |
M12 Power, A-coded (X2) | |
Ethernet/IP cable, at least cat. 5e | M12, D-coded, screened (X4) |
Ethernet/IP cable, at least cat. 5e | M12, D-coded, screened (X3) |
M12 Power, A-coded (X1) | |
Installation orientation | Door hinge DIN left |
Switching frequency | 0.25 Hz |
Mechanical life | |
1 x 10⁶ | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
Response time | |
Bolt position | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Door position | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Emergency stop / machine stop | max. 100 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Key-operated rotary switch | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Guard locking | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP54 |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Locking force FZh | 2000 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Mission time | 20 y |
Safety Integrity Level | SIL 3 (EN 62061:2005) |
Control of guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.91 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.) |
Emergency stop | |
B10D | |
Emergency stop | 0.13 x 10⁶ |
Emergency-stop evaluation | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.05 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.) |
Key-operated rotary switch evaluation | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.74 x 10-12 (Fixed failure rate without consideration of faults in wearing parts.) |
Key-operated rotary switch | |
B 10 | |
Key-operated rotary switch | 0.03 x 10⁶ |
Monitoring of guard locking and the guard position | |
Diagnostic Coverage (DC) | 99 % |
Category | 4 |
Performance Level | PL e |
PFHD | 3.37 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.) |
Miscellaneous
Product version number | V1.5 |
Interface
Bus data protocol | Ethernet/IP |
Safety data protocol | CIP Safety |
Date interface | |
Ethernet |
Komponensek
106051
MGB-E-A2-106051
Escape release module MGB-E... pre-assembled on mounting plate
MGB-E-A2-106051
Escape release module MGB-E... pre-assembled on mounting plate
- Escape release from the danger zone
- Mounted on mounting plate
- Signal red door handle
- Designed for door profiles up to 40 mm
- Extended actuation axis for thicker doors (available optionally)
111839
MGB-H-AA1A6-L-111839
Handle module MGB-H... with automatically extending lockout mechanism
MGB-H-AA1A6-L-111839
Handle module MGB-H... with automatically extending lockout mechanism
- Intelligent bolt tongue
- Fold-out lockout mechanism
- Second automatically extending lockout mechanism
- Door handle
- Mounting plate
136485
MGB-L1B-EIA-L-136485
Locking module MGB-L1...-EI (guard locking by spring force) with 3 pushbuttons, emergency stop and key-operated rotary switch
MGB-L1B-EIA-L-136485
Locking module MGB-L1...-EI (guard locking by spring force) with 3 pushbuttons, emergency stop and key-operated rotary switch
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850
- 3 illuminated pushbuttons
- OM.R key-operated rotary switch (2-channel)
- Connection via M12 plug
- Pre-assembled on mounting plates
- Integrated switch
- Unicode
Tartozékok
Letöltések
Teljes csomag
Minden fontos dokumentum letöltése egyetlen kattintással.
Tartalom:
- A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
- A használati utasítást kiegészítő adatlapok
- A megfelelőségi nyilatkozat
Egyedi dokumentumok
Declarations of conformity
EU-Konformitätserklärung
Dok. sz.
Változat
Nyelv
Méret
EU-Konformitätserklärung
Dok. sz.
EDC2123624
Változat
Nyelv
Méret
0,2 MB
UKCA-Konformitätserklärung
Dok. sz.
Változat
Nyelv
Méret
UKCA-Konformitätserklärung
Dok. sz.
EDC20001506
Változat
Nyelv
Méret
0,1 MB
Instructions
Operating Instructions Safety Systems MGB-L..B-EI-… (Ethernet/IP) and With Data Structure Type A From V1.5.0
Dok. sz.
Változat
Nyelv
Méret
Operating Instructions Safety Systems MGB-L..B-EI-… (Ethernet/IP) and With Data Structure Type A From V1.5.0
Dok. sz.
2126330
Változat
09/21
Nyelv
Méret
2,9 MB
Manual de instrucciones Sistemas de seguridad MGB-L..B-EI-… (Ethernet/IP) y con estructura de datos de tipo A V1.5.0 o superior
Dok. sz.
2126330
Változat
09/21
Nyelv
Méret
3,0 MB
Betriebsanleitung Sicherheitssysteme MGB-L..B-EI-… (Ethernet/IP) und mit Datenstruktur Typ A ab V1.5.0
Dok. sz.
2126330
Változat
09/21
Nyelv
Méret
2,9 MB
사용 설명서 안전 시스템 MGB-L..B-EI-…(이더넷/IP) 데이터 구조 타입 A 포함 V1.5.0부터
Dok. sz.
2126330
Változat
09/21
Nyelv
Méret
3,3 MB
Instrucțiuni de utilizare Sisteme de siguranță MGB-L..B-EI-… (Ethernet/IP) și cu structură de date tip A începând de la versiunea V1.5.0
Dok. sz.
2126330
Változat
09/21
Nyelv
Méret
3,1 MB
Egyéb dokumentumok
Rendelési adatok
Rend. sz. | 166743 |
Cikk neve | MGB-L1HEB-EIA-L-166743 |
Súly | 6,98kg |
Vámtarifaszám | 85371098 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |