MGB-L2HEB-EIA-R-161479 (Rend. sz. 161479)

Locking set MGB-L2...-EI (guard locking by solenoid force) with 4 pushbuttons, emergency stop, 7/8" and M12 plugs

  • Guard locking with guard lock monitoring
  • Emergency stop according to ISO 13850, illuminated
  • 4 illuminated pushbuttons
  • including adhesive labels
  • Connection via 7/8" and M12 plugs
  • including terminal plug for stack light (M12, 5-pin)
  • Pre-assembled on mounting plates
  • With escape release
  • Unicode
MGB-L2HEB-EIA-R-161479 (Rend. sz. 161479)

Ismertetés

Ethernet/IP connection

7/8" and M12 plugs (d-coded)

Integrated switches

Integrated switches permit linear and DLR network structures

Flexible use as interlocking or guard locking

By means of the corresponding evaluation of the safe device data by the control system, use can be as either interlocking or guard locking (with or without monitoring).

Illuminated emergency stop

Emergency stop with illumination that can be controlled as required.

Escape release

The escape release enables people accidentally shut in to open the guard locked door from the danger zone.

Dimension drawing
Dimension drawing
MGB: impact test
MGB: mounting door on right, without escape release
MGB: mounting door on left, with escape release
MGB: mounting door on left, without escape release
MGB: in use
MGB: deactivating guard lock monitoring
MGB: pushbutton lens replacement
MGB: activating release monitoring
MGB: activating guard lock monitoring

Dimensional drawings

Dimensional drawings

Műszaki adatok

Approvals

c_UL_us_E155795_3/9EAC_RU C-DE.HX37.B.14157/20

Handle modules MGB-H-AA1A2-R-106049 (Order no. 106049)

Handle modules MGB-H-AA1A2-R-106049  (Order no. 106049)

Mechanical values and environment

Installation orientation Door hinge DIN right
Degree of protection IP65
Ambient temperature -20 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Miscellaneous

Product version number V3.0.0
Additional feature with mounting plate

Escape release MGB-E-A2-106051 (Order no. 106051)

Escape release MGB-E-A2-106051  (Order no. 106051)

Mechanical values and environment

Installation orientation any
Mechanical life 1 x 10⁶
Ambient temperature -30 ... +55 °C
Material
Housing Die-cast zinc/stainless steel, powder-coated

Miscellaneous

Product version number V2.0.0
Additional feature with mounting plate

Locking modules MGB-L2B-EIA-R-136511 (Order no. 136511)

Locking modules MGB-L2B-EIA-R-136511  (Order no. 136511)

Workspace

Secured switch-off distance sar
Door position max. 65 mm

Operating and display elements

Occupancy diagram
B1
L1
ItemColorExtrasSwitching elementSlide-in labelNote slide-in labelVersionNumberDesignation1LED
1with adhesive ring2 PDEmergency stop illuminated
90Red1NOIlluminated pushbutton
92Green1NOIlluminated pushbutton
93Yellow1NOIlluminated pushbutton
95Green1NOIlluminated pushbutton

Electrical connection values

Connecting cable
Ethernet Ethernet/IP cable, at least cat. 5e
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
maximum feed-in current in the connection block
X1, X2 max. 4000 mA
Safety class III
Current consumption max. 500 mA
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3
Power supply X1
Fuse
external min. 1 A slow blow
Operating voltage DC
L1 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... +10% (For looping through for connected devices)
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (For looping through for connected devices)

Mechanical values and environment

Connection type
Plug connector M12 (X6)
7/8" Power (X1)
Ethernet/IP cable, at least cat. 5e M12, D-coded, screened (X4)
7/8" Power (X2)
Ethernet/IP cable, at least cat. 5e M12, D-coded, screened (X3)
Installation orientation Door hinge DIN right
Switching frequency 0.25 Hz
Mechanical life
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
1 x 10⁶
Response time
Emergency stop / machine stop max. 100 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Door position max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Bolt position max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Guard locking max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP54
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel
Locking force FZh 2000 N
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
Safety Integrity Level SIL 3 (EN 62061:2005)
Control of guard locking
Category 4
Performance Level PL e
PFHD 4.91 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.)
Emergency stop
B10D
Emergency stop 0.13 x 10⁶
Emergency-stop evaluation
Category 4
Performance Level PL e
PFHD 3.05 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.)
Monitoring of guard locking and the guard position
Diagnostic Coverage (DC) 99 %
Category 4
Performance Level PL e
PFHD 3.37 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.)

Miscellaneous

Slide-in label
NumberLabelingNote
4without marking
Product version number V1.5

Interface

Bus data protocol Ethernet/IP
Safety data protocol CIP Safety
Date interface
Ethernet

Tartozékok

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 11,2 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 161479
Cikk neve MGB-L2HEB-EIA-R-161479
Súly 6,96kg
Vámtarifaszám 85371098
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu

Cookie-értesítés

Műszakilag szükséges sütiket használunk, amelyek a weboldal működéséhez elengedhetetlenek. Ezenkívül statisztikai sütit használunk a weboldalunk használatának elemzésére és kínálatunk folyamatos fejlesztésére. Ön maga döntheti el, hogy beleegyezik-e a statisztikai cookie használatába. További információk az adatvédelmi szabályzatunkban találhatók.