EUCHNER – More than safety.
EUCHNER – More than safety.

MGBS-P-L1-AR-U-R-AEE-SH-161206 (Rend. sz. 161206)

MGBS-AR, M23, 1 pushbutton, with escape release, door hinge on right

  • Locking module (order handle module separately)
  • Adjustable door hinge; factory setting: right
  • Series connection possible (up to 20 AR devices in series)
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • 1 pushbuttons (illuminated)
  • With plug connector M23
  • Unicode
  • Door position monitoring output
  • With escape release (order inner door handle separately)
MGBS-P-L1-AR-U-R-AEE-SH-161206 (Rend. sz. 161206)

Ismertetés

Door hinge

The door hinge can be changed.

Unicode evaluation

Each handle module is highly coded (unicode). The locking module detects only handle modules that have been taught-in. Additional handle modules can be taught-in. Only the last handle module taught-in is detected.

Guard locking type

MGBS-L1

Guard locking actuated by spring force and power-ON released (closed-circuit current principle).

Lens set

The color of the pushbuttons can be selected using the color cover set included (5 colors).

Escape release

It is used for manual release of the guard locking without tools in an emergency. The inner door handle permits escape from the danger zone.

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1IMPSolenoid operating voltage, 24 V DCVT
2FI1AEnable input, channel ARD
3FI1BEnable input, channel BGY
4FO1ASafety output, channel ARD/BU
5FO1BSafety output, channel BGN
6UBElectronics operating voltage, 24 V DCBU
7RSTReset inputGY/PK
8ODDoor position monitoring outputGN/WH
9OIDiagnostic monitoring outputYE/WH
10OLGuard lock monitoring outputGY/WH
11-n.c.BK
12FEFunctional earth (must be connected to meet the EMC requirements)GN/YE
13IMMSolenoid operating voltage, 0 V DCPK
14-n.c.BN/GY
15-n.c.BN/YE
16-n.c.BN/GN
17S3Pushbutton 3 (illuminated)WH
18H3LED 3YE
190VUBElectronics operating voltage, 0 V DCBN
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
MGBS
Multifunctional door locking systems

Dimensional drawings

Dimensional drawings
1LEDs
2Auxiliary release
3Pushbutton 1 illuminated

Connection examples

Connection examples

Műszaki adatok

Approvals

c_UL_us_E155795_3/11FCC_2AJ58-05_

Workspace

Repeat accuracy R
according to EN 60947-5-2 10 %

Operating and display elements

ItemColorExtrasVersionNote slide-in labelSlide-in labelSwitching elementNumberDesignation1LED
3Illuminated pushbutton1NO

Electrical connection values

Fuse
external (operating voltage UB) 0.25 ... 8 A
external (solenoid operating voltage IMP) 0.5 ... 8 A
Power consumption 6 W
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 0.5 kV
Operating voltage DC
UUB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
EMC protection requirements Acc. to EN IEC 60947-5-3
Utilization category
DC-13 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV
Solenoid duty cycle 100 %
Risk time according to EN 60947-5-3 max. 260 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Switching load
according to UL 24V DC, Class 2 (alternatively, see operating instructions)
Safety class
EN IEC 61140 III
Current consumption
IUB 40 mA
IIMP 400 mA
Test pulse duration max. 1.0 ms (Applies to a load with C<= 30 nF and R<= 20 kohm)
Test pulse interval min. 140 ms
Degree of contamination (external, according to EN 60947-1) 3
Controls and indicators
Operating voltage UB V
Operating current 1 ... 50 mA
Power supply
LED 24 V
Current consumption
LED 10 mA
Monitoring output OD, OI, OL
Output type p-switching, short circuit-proof
Output voltage 0.8xUB ... UB V DC
Switching current 1 ... 50 mA
Safety outputs FO1A / FO1B
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage
HIGH U(FO1A) / U(FO1B) UB-1.5 ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Discrepancy time
both safety outputs max. 10 ms Acc. to EN IEC 60947-5-3
Turn-on time max. 400 ms
Off-state current Ir max. 0.25 mA
Switching current
per safety output FO1A / FO1B 1 ... 150 mA

Mechanical values and environment

Approach speed max. 20 m/min
Connection type 1 plug connector M23, 19-pin, RC18
Extraction force 20 N
Ready delay 8 s
Actuating force 10 N
Installation orientation Door hinge DIN right
Switching frequency max. 0.5 Hz
Mechanical life 1 x 10⁶
Overtravel 5 mm
Retention force 20 N
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (screwed tight plug connector/mating component)
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Material
Switch bracket Die-cast zinc
Safety switch housing Reinforced thermoplastic
Locking force Fmax 3900 N
Locking force FZh 3000 N (Fzh = Fmax/1.3, depending on the actuator used)
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of guard lockingPL e-4.1x10-9420 y


PLMaximum SILCategoryMission time
Control of guard lockingDepending on external control of guard locking20 y


Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions
Additional feature
Escape release actuated by pushing
incl. lens set, ID no. 120344

Tartozékok

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 16,3 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 161206
Cikk neve MGBS-P-L1-AR-U-R-AEE-SH-161206
Súly 2,178kg
Vámtarifaszám 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu

Cookie-értesítés

Műszakilag szükséges sütiket használunk, amelyek a weboldal működéséhez elengedhetetlenek. Ezenkívül statisztikai sütit használunk a weboldalunk használatának elemzésére és kínálatunk folyamatos fejlesztésére. Ön maga döntheti el, hogy beleegyezik-e a statisztikai cookie használatába. További információk az adatvédelmi szabályzatunkban találhatók.