TP AS2 safety switch, plug connector(s) M12 (open-circuit current principle)
- Auxiliary release on the front
- Increased horizontal overtravel
- Optionally without guard lock monitoring
Ismertetés
Guard locking types
TP3 | Closed-circuit current principle, guard locking by spring force. Release by control of AS-i output 0. |
TP4 | Open-circuit current principle, guard locking by control of AS-i output 0. Release by spring force. |
Control of the guard locking solenoid
The guard locking solenoid is controlled by the control system via AS-Interface bus bit D0. In addition, the 24V connection can be switched safely.
AS-Interface inputs version AS2
D0, D1 | Door monitoring contact SK 1 |
D2, D3 | Door monitoring contact SK 2 |
Evaluation is performed via a safety monitor.
AS-Interface outputs
D0 | Guard locking solenoid |
D1 | LED red |
D2 | LED green |
LED function display
- The Power LED indicates the operating voltage on the bus.
- The Fault LED indicates if a fault has been detected on the AS-Interface bus.
- The green and the red LEDs can be controlled as required by the control system via the bus using bits D1 and D2.
Auxiliary release
This is used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.
Dimensional drawings
1 | Auxiliary release |
2 | Locking screw |
3 | LED indicator |
Connection examples
View of plug side |
Műszaki adatok
Approvals
Electrical connection values
ASI operating current | max. 45 mA |
ASI data in | |
according to AS-i Safety at Work | D0, D1, D2, D3 (see positively driven contact) |
ASI data out | |
LED red | D1 (1 = LED on) |
LED green | D2 (1 = LED on) |
Guard locking solenoid | D0 (1 = Solenoid energized) |
AS-Interface auxiliary voltage | |
IEC 60742, PELV | 24 V -15% ... +10% |
Auxiliary current AS-Interface | 300 mA |
AS-Interface LED | |
green | Power |
red | Fault |
AS-Interface protocol | ASi-3 |
AS-Interface slave type | ID-Code: B, EA-Code: 7 |
ASI voltage | 22.5 ... 30 ... 31.6 V |
Solenoid duty cycle | 100 % |
Mechanical values and environment
Approach speed | max. 20 m/min |
Approach direction | A |
Connection type | |
1 x | Plug connector M12 (4-pin) |
Number of door position positively driven contacts | |
according to AS-i Safety at Work | 2 (D0,D1,D2,D3 / 1 = door closed) |
Extraction force | 20 N |
Actuation frequency | max. 1200 1/h |
Actuating force | 10 N |
Installation orientation | any |
Vertical insertion depth | 29.5 mm |
Mechanical life | 1 x 10⁶ |
Retention force | 10 N |
Switching principle | Slow-action switching contact |
Degree of protection | IP67 |
Ambient temperature | -20 ... +55 °C |
Material | |
Contact | Silver alloy, gold flashed |
Housing | Reinforced thermoplastic |
Locking force Fmax | 1300 N |
Locking force FZh | 1000 N |
Guard locking principle | Open-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
B10D | Mission time | |
---|---|---|
Monitoring of the guard position | 3x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V | ||
Monitoring of guard locking | 3x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V |
In combination with actuator ACTUATOR-P-GT
Horizontal insertion depth | 28 mm |
Vertical insertion depth | 29.5 mm |
Horizontal overtravel | 2 mm |
Vertical overtravel | 1.5 mm |
In combination with actuator ACTUATOR-P-GNT
Horizontal insertion depth | 28 mm |
Horizontal overtravel | 7 mm |
Tartozékok
AE-K-A1-DULK1-84177
- Lock unique locking
- Key removable in “unlocked” and “locked” positions
AE-K-A1-IULK1-86236
- Identical locking
- Key removable in “unlocked” and “locked” positions
AE-K-A1-IUK2-109212
- Identical locking
- Key can be removed only in “unlocked” position
AE-K-A1-ILK1-121917
- Identical locking
- Key removable in “locked” position
AE-B-A1-02,0-096230
- Can be used as escape release or emergency release
- no automatic return
- Sheath length 2 m (rope length 6 m)
AE-B-A1-02,0-F-097747
- Can be used as escape release or emergency release
- automatic return
- Sheath length 2 m (rope length 6 m)
AE-B-A1-03,0-098313
- Can be used as escape release or emergency release
- no automatic return
- Sheath length 3 m (rope length 6 m)
AE-B-A1-04,0-098314
- Can be used as escape release or emergency release
- no automatic return
- Sheath length 4 m (rope length 6 m)
AE-B-A1-03,0-F-111233
- Can be used as escape release or emergency release
- automatic return
- Sheath length 3 m (rope length 6 m)
AE-B-A1-06,0-125582
- Can be used as escape release or emergency release
- no automatic return
- Rope length 6 m (without sheath)
AE-B-A1-06,0-F-124770
- Can be used as escape release or emergency release
- automatic return
- Rope length 6 m (without sheath)
RIEGEL 0 NP/TP OHNE RASTUNG
- Bolt for safety switch NP... and TP...A
- Steel bolt
- For doors hinged on the left or right
- Suitable for a door gap of approx. 6 mm
RIEGEL 1 NP/TP 1X RASTUNG ZU
- Bolt for safety switch NP...AS,TP...A and GP
- Steel bolt
- For doors hinged on the left or right
- Suitable for a door gap of approx. 15 mm
Letöltések
Teljes csomag
Minden fontos dokumentum letöltése egyetlen kattintással.
Tartalom:
- A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
- A használati utasítást kiegészítő adatlapok
- A megfelelőségi nyilatkozat
Egyedi dokumentumok
Déclaration UE de conformité
Declaración de conformidad UE
EU-Konformitätserklärung
Dichiarazione UE di conformità
Déclaration UE de conformité
Declaración de conformidad UE
EU-Konformitätserklärung
Dichiarazione UE di conformità
Mode d’emploi Interrupteur de sécurité TP…AS2
Manual de instrucciones Interruptor de seguridad TP…AS2
Betriebsanleitung Sicherheitsschalter TP…AS2
Egyéb dokumentumok
Rendelési adatok
Rend. sz. | 091676 |
Cikk neve | TP4-4141A024SEM4AS2 |
Súly | 0,469kg |
Vámtarifaszám | 85365019000 |
ECLASS | 27-27-26-03 Safety switch with guard control |