Non-contact safety switch CET-AP-..., M12
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4 / PL e according to EN ISO 13849-1
- With 1 plug connector M12, 8-pin
- Multicode
- Door monitoring output
- Indication of the door position by LED
- Escape release, 75 mm long
- Approach direction A (delivery state)
Ismertetés
Safety switch
The device may be operated only in conjunction with the actuator CET-A-....
Important: The actuator must be ordered separately.
Multicode evaluation
Every suitable actuator is detected by the switch.
Solenoid operating voltage
- DC 24 V +10%, -15%
Guard locking type
CET4 | Open-circuit current principle, guard locking by solenoid force. Activation of the guard locking by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D also remains set when guard locking is active. |
LED function display
State LED | Status LED |
DIA LED | Diagnostics LED |
LED 1 rd | illuminates when the solenoid is energized |
LED 2 gn | illuminates when door is closed |
Additional connections
OUT | Monitoring output (semiconductor) |
OUT D | Door monitoring output |
Category according to EN ISO 13849-1
Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4 / PL e according to EN ISO 13849-1
- The stated safety characteristics apply to any installation orientations of the safety switch.
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.
Escape release
This is used for manual release of guard locking from the danger zone without tools.
Dimensional drawings
Connection examples
Connection examples
Műszaki adatok
Approvals
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | 10 % |
Electrical connection values
Fuse | |
external (operating voltage UB) | 0.25 ... 8 A |
external (solenoid operating voltage UCM) | 0.5 ... 8 A |
Power consumption | |
Solenoid | 11 W |
Connecting cable | 30V DC, 2A (for UL requirement UL category code (CYJV/CYJV7)) |
Operating voltage DC | |
LED | 24 V DC -15% V DC ... +10% V DC |
UB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV (The device tolerates voltage interruptions of up to 5 ms) |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Utilization category | |
DC-13 | 24 V 200 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads) |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV |
Solenoid duty cycle | 100 % |
Risk time according to EN 60947-5-3 | max. 400 ms |
Switching load | |
according to UL | 24V DC, Class 2 (For alternatives, see operating instructions) |
Safety class | III |
Current consumption | |
ICM | 450 mA |
IB | 80 mA |
Test pulse duration | max. 0.3 ms (Applies to a load with C<= 30 nF and R<= 20 kohm) |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring output OUT D | |
Output type | p-switching, short circuit-proof |
Output voltage | |
OUT D | 0.8xUB ... UB V DC |
Switching current | |
OUT D | 1 ... 50 mA |
Switching delay from state change | max. 700 ms |
Monitoring output OUT | |
Output type | p-switching, short circuit-proof |
Output voltage | |
OUT | 0.8xUB ... UB V DC |
Switching current | |
OUT | 1 ... 50 mA |
Switching delay from state change | max. 400 ms |
Safety outputs OA / OB | |
Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
HIGH U(OA,OB) | UB-1.5V ... UB V DC |
LOW U(OA,OB) | 0 ... 1 V DC |
Discrepancy time | |
both safety outputs | max. 10 ms |
Turn-on time | 400 ms |
Off-state current Ir | max. 0.25 mA |
Risk time according to EN 60947-5-3 | |
Single device | |
Switching current | |
per safety output OA / OB | 1 ... 200 mA |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection type | 1 plug connector M12, 8-pin |
Ready delay | 1 s |
Installation orientation | any |
Switching frequency | max. 0.5 Hz |
Degree of freedom X | ±5 mm |
Degree of freedom Y | ±5 mm |
Degree of freedom Z | ±4 mm |
Mechanical life | 2 x 10⁶ |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP67 (When inserted and secured) |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Material | |
Ramp | Stainless steel |
Safety switch housing | Die-cast aluminum |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N (FZH = FMAX/1.3) |
Guard locking principle | Open-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of guard locking | PL e | - | 3.1x10-9 | 4 | 20 y |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
Tartozékok
AM-C-SW4-V3-161344
- Plastic inserts for hexagon socket screws a/f 4
- Efficient protection against tampering for safety switch mounting
- The packaging includes inserts for 18 screws
AM-C-SW5-V3-161348
- Plastic inserts for hexagon socket screws a/f 5
- Efficient protection against tampering for safety switch mounting
- The packaging includes inserts for 18 screws
Letöltések
Teljes csomag
Minden fontos dokumentum letöltése egyetlen kattintással.
Tartalom:
- A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
- A használati utasítást kiegészítő adatlapok
- A megfelelőségi nyilatkozat
Egyedi dokumentumok
Egyéb dokumentumok
Rendelési adatok
Rend. sz. | 161178 |
Cikk neve | CET4-AP-CRA-CH-50F-SA-161178 |
Súly | 1,4kg |
Vámtarifaszám | 85365019000 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |