EUCHNER – More than safety.
EUCHNER – More than safety.

CTP-L1-AP-U-HA-AZ-SII-129477 (Rend. sz. 129477)

Transponder-coded safety switch CTP-AP, 2 x M12

  • Safety switch with guard locking and integrated evaluation electronics
  • Direct connection to decentralized peripheral systems (e.g. ET200pro)
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • With 2 plug connectors M12
  • Unicode
  • Door monitoring output
  • Approach directions A, B and C (delivery state)
CTP-L1-AP-U-HA-AZ-SII-129477 (Rend. sz. 129477)

Ismertetés

Approach direction

Horizontal

Can be adjusted in 90° steps

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.

Guard locking type

CTP‑L1

Guard locking actuated by spring force and power-ON released (closed-circuit current principle).

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

X 1.1UBOperating voltage of AP electronics, 24 V DCBN
X 1.2FO1ASafety output, channel 1WH
X 1.30 V UBAP electronics operating voltage, 0 VBU
X 1.4FO1BSafety output, channel 2BK
X 1.5-Not usedGY
X 2.1-Not usedBN
X 2.2ODDoor monitoring outputWH
X 2.3IMMControl input of guard locking solenoid, 0 VBU
X 2.4IMPControl input of guard locking solenoid, 24 V DCBK
X 2.5-Not usedGY
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
CTP at a glance

Dimensional drawings

Dimensional drawings
1Auxiliary release
2Locking screw
3LEDs

Connection examples

Connection examples

Műszaki adatok

Approvals

EAC_RU C-DE.MO05.B.00971/20DGUV_CTP_ET 22017_ET 22018c_UL_us_E155795_3/11FCC_2AJ58-05_

Workspace

Repeat accuracy R
according to EN 60947-5-2 10 %

Electrical connection values

Fuse
external (operating voltage UB) 0.25 ... 8 A
external (solenoid operating voltage IMP) 0.5 ... 8 A
Power consumption 6 W
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 0.5 kV
Operating voltage DC
UUB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
EMC protection requirements Acc. to EN IEC 60947-5-3
Utilization category
DC-13 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV
Solenoid duty cycle 100 %
Switching load
according to UL 24V DC, Class 2 (alternatively, see operating instructions)
Safety class III
Current consumption
IUB 40 mA
IIMP 400 mA
Test pulse duration max. 0.3 ms (Applies to a load with C<= 30 nF and R<= 20 kohm)
Test pulse interval min. 100 ms
Degree of contamination (external, according to EN 60947-1) 3
Monitoring output OD
Output type p-switching, short circuit-proof
Output voltage 0.8xUB ... UB V DC
Switching current 1 ... 50 mA
Safety outputs FO1A / FO1B
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage
HIGH U(FO1A) / U(FO1B) UB-1.5 ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Discrepancy time
both safety outputs max. 10 ms Acc. to EN IEC 60947-5-3
Turn-on time max. 400 ms
Off-state current Ir max. 0.25 mA
Switching current
per safety output FO1A / FO1B 1 ... 150 mA

Mechanical values and environment

Approach speed max. 20 m/min
Connection type 2 plug connectors M12, 5-pin + pin 5 not used
Extraction force 20 N
Ready delay max. 1 s
Actuating force 10 N
Installation orientation any
Switching frequency max. 0.5 Hz
Mechanical life 1 x 10⁶
Overtravel 5 mm
Retention force 20 N
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67/IP69/IP69K (When inserted and secured)
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Material
Safety switch housing Reinforced thermoplastic
Switch head cover Die-cast zinc
Locking force Fmax 3900 N
Locking force FZh 3000 N (Fzh = Fmax/1.3, depending on the actuator used)
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of guard lockingPL e-4.1x10-9420 y


PLMaximum SILCategoryMission time
Control of guard lockingDepending on external control of guard locking20 y


Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Tartozékok

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 12,9 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 129477
Cikk neve CTP-L1-AP-U-HA-AZ-SII-129477
Súly 0,6kg
Vámtarifaszám 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu

Cookie-értesítés

Műszakilag szükséges sütiket használunk, amelyek a weboldal működéséhez elengedhetetlenek. Ezenkívül statisztikai sütit használunk a weboldalunk használatának elemzésére és kínálatunk folyamatos fejlesztésére. Ön maga döntheti el, hogy beleegyezik-e a statisztikai cookie használatába. További információk az adatvédelmi szabályzatunkban találhatók.