EUCHNER – More than safety.
EUCHNER – More than safety.

Safety switch CTP-AR

Benefits for you

  • Safety switch with guard locking and safe guard lock monitoring
  • Integrated CES-AR electronics
  • A special evaluation unit is not required
  • Up to 20 AR devices can be connected in series in a chain
  • Safety category 4 and PL e according to EN ISO 13849-1
  • Mounting compatible with existing safety switches
The safety switch CTP combines the proven principle of operation of electromechanical safety switches with guard locking and modern transponder-coded safety engineering.
Thanks to the transponder technology, even a single CTP achieves category 4/PL e according to EN ISO 13849-1, without additional fault exclusion, and meets all the requirements of EN ISO 14119. It is ideally suited to applications in which a high Performance Level and a locking force of up to 3,900 N are required
Safety switch CTP-AR

Versatile use

The CTP reliably secures safety doors and flaps on machines and systems. Thanks to the integrated guard locking and guard lock monitoring, it can be used both for process protection and the protection of personnel. Its compact design permits space-saving mounting on the guard.
With a guard locking force of 3,900 N the CTP effectively prevents the opening of safety doors. The very robust plastic housing with metal head as well as the high degree of protection IP67/IP69/IP69K make the CTP the all-rounder for almost every industrial use. The CTP is suitable even for harsh, dirty environments.

Mounting and principle of operation

The CTP consists of two components, a safety switch and a separate actuator. The safety switch is mounted on the fixed part of the guard, the actuator on the movable part.
The CTP can be approached from four directions. For improved insertion of the actuator, the head is equipped with an integrated funnel. This feature is particularly advantageous on unstable door designs as well as if the door is incorrectly adjusted.
When the guard is closed, the actuator moves into the head on the safety switch. The safety outputs are switched on if the integrated transponder chip in the actuator is detected and the guard locking activated.
Thanks to the integrated prevention of inadvertent locking position (faulty closure protection), unintentional activation of the safety outputs is prevented if the actuator is not completely inserted into the head.

System family AR

In the AR version up to 20 safety switches CTP or other EUCHNER products that belong to the AR system family can be connected in series. 2 different wiring concepts are available:
Series connection in the control cabinet:
Wiring takes place in the control cabinet. All information about the status of individual CTPs can be forwarded directly to the control system.
Series connection in the field:
For field wiring, EUCHNER offers the option of using M12 plugs and Y-distributors to connect together several CTPs.
Instead of the Y-plug connectors, it is also possible to use a passive distribution module. On this device, all safety and status signals are collected together in the field and forwarded to the control system using one cable.

Termékek (19)

Nem található eredmény

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu

Cookie-értesítés

Műszakilag szükséges sütiket használunk, amelyek a weboldal működéséhez elengedhetetlenek. Ezenkívül statisztikai sütit használunk a weboldalunk használatának elemzésére és kínálatunk folyamatos fejlesztésére. Ön maga döntheti el, hogy beleegyezik-e a statisztikai cookie használatába. További információk az adatvédelmi szabályzatunkban találhatók.