Read-only head CIT3 with parallel interface, plugged in axially
- Parallel interface
- Cylindrical design M30
- M12 plug connector
- Axial connection
Açıklama
Mounting instructions
On mounting the read head and data carrier, it is to be ensured the crossing direction as per the direction of the arrow on the active face of the read head is observed.
Attention:
On the use of a screened cable the connecting cable is allowed to be max. 50 m long.
Dimensional drawings
1 | LED |
1) | Clear zone |
2 | Active face |
3 | Crossing direction |
m | Center offset |
s | Read distance |
Connection examples
Teknik Veriler
Approvals
Operating and display elements
LED display | Yellow: data carrier active |
Electrical connection values
Output type | Push-pull |
Output voltage | |
0 ... 2 V DC for LOW level | |
UB - 3 ... UB V DC for HIGH level | |
Operating voltage DC | 20 ... 24 ... 28 V DC (All the electrical connections must either be isolated from the mains supply by a safety transformer according IEC/ EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.) |
Input voltage | |
max. 2 V DC SKIP input LOW level | |
min. 15 V DC SKIP input HIGH level | |
Switching current | |
per output | -30 ... +30 mA |
Current consumption | |
without load | 65 ... 100 mA |
Resistance | 4.5 kΩ Input resistance |
Mechanical values and environment
Connection type | M12 plug, 8-pin, axial connection (The shield on the connecting cable is connected to the read head's housing via the knurled nut on the M12 plug connector.) |
Mounting type | surface |
Degree of protection | IP67 |
Ambient temperature | 0 ... +50 °C |
Material | |
Housing | CuZn, nickel plated |
Interface
Date interface | 4-bit parallel, binary coded via HIGH/LOW level |
In combination with data carrier CIS3P16D08KH16YSNOU, CIS3P16D08KH16YSNOP
Read distance | 0 ... 5 ... 14 mm |
Center offset | |
at 25 °C | -6 ... 6 mm (Center offset mL in y direction (for sL = 5 mm)) |
at 25 °C | -18 ... 18 mm (Center offset mL in x direction (for sL = 5 mm)) |
In combination with data carrier CIS3P35X16SH16YHNOU, CIS3P35X16SH16YHNOP, CIS3P35X16SH16YVNOU, CIS3P35X16SH16YVNOP
Read distance | |
at 21 °C | 0 ... 7 ... 18 mm |
Center offset | |
at 21 °C | -23 ... 23 mm (Center offset mL in x direction (for sL = 7 mm)) |
at 21 °C | -8 ... 8 mm (Center offset mL in y direction (for sL = 7 mm)) |
Aksesuar
Connection material
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler
Declarations of conformity
EU-Konformitätserklärung
Dok. No.
Versiyon
Dil
Boyut
EU-Konformitätserklärung
Dok. No.
EDC2077155
Versiyon
Dil
Boyut
0,2 MB
UKCA-Konformitätserklärung
Dok. No.
Versiyon
Dil
Boyut
UKCA-Konformitätserklärung
Dok. No.
EDC20001517
Versiyon
Dil
Boyut
0,1 MB
Diğer Belgeler
CAD Verileri
Sipariş verileri
Sip. No. | 071552 |
Makale adı | CIT3PL1N30-STA |
Ağırlık | 0,22kg |
Gümrük sınıfı | 85389099990 |
ECLASS | 27-28-04-01 Identification, RFID Reader |