EUCHNER – More than safety.
EUCHNER – More than safety.

HBAS-072949 (Sip. No. 072949)

Hand-held pendant station HBAS, EMERGENCY STOP device, pushbuttons, membrane keypad, programmable pulse generator, LC display

  • Programmable pulse generator
  • Tamper-proof EMERGENCY STOP device according to EN ISO 13850, dual-channel
  • Membrane keypad with 20 keys and 2 LEDs
  • LC display with LED background lighting, switchable 4-line/8-column or 8-line/16-column
  • RS422 interface, 3964R protocol
  • 2 pushbuttons, 2-stage, 1 NO contact each, e.g. for enabling function
  • Coiled cable can be expanded to 3.5 m
HBAS-072949 (Sip. No. 072949)

Açıklama

Notes

  • ActiveX module available for integrating the user’s application (for ActiveX capable user programs under MS Windows®)
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
Hand-held pendant stations and hand wheels

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00972/20c_UL_us_E206093_1/2

Operating and display elements

ItemColorExtrasNote slide-in labelSlide-in labelVersionSwitching elementNumberDesignation1LED
---Display-1
---Pulse generator-1
see data sheetsred-black with yellow plate-Emergency stop2 pos. driven contacts1
see data sheets--Membrane keys-20
see data sheets--Pushbutton1 NO contact each2
see data sheets--LED-2

Electrical connection values

Connecting cable 23x0.14 mm²
Output type
Pulse generator RS422
Operating voltage DC 24 V DC -20% ... +20%
Utilization category
DC-13 Emergency stop 30 V / 3 A
Switching voltage
Pushbutton max. DC 50 V
Pushbutton max. AC32 V
Switching current
Pushbutton max. 100 mA
Current consumption max. 100 mA (without switched-on LEDs)

Mechanical values and environment

Connection type Plug connector (19-pin, metal version)
Cable length
coiled 3.5 m (extended)
Atmospheric humidity
Condensation not permissible max. 80 % rH
Shock and vibration resistance according to EN 60068-2-27/-2-6
Degree of protection
IP65 (When installed)
according to NEMA 250-12 (When installed)
Ambient temperature 0 ... +50 °C
Material Polycarbonate

Miscellaneous

Color
Housing Gray RAL 7040
The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures
Additional feature
Acoustic sensor (see manual)
Pulse generator (see manual)
Firmware update (see manual)

Interface

Data protocol 3964R, 8 data bits, even parity
Data rate 9.6 ... 19.2 kbit/s (automatic adjustment during initialization)
Date interface RS422

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 2,1 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 072949
Makale adı HBAS-072949
Ağırlık 1,5kg
Gümrük sınıfı 85371098
ECLASS 27-33-02-02 Mobile Panel (HMI)

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.