Read heads CMS design A - with NC/NO contacts, PVC
- In combination with evaluation units CMS-E-BR/CMS-E-ER/CMS-E-FR
- Cube-shaped version, 88 x 25 mm
- Connecting cable
- Cable type: PVC
Açıklama
Dimensional drawings
Connection examples
Teknik Veriler
Approvals
Workspace
Secured switch-off distance sar | max. 31 mm (The assured release distance corresponds to the reset distance) |
Secured switching distance sao | |
with center offset m=0 | min. 6 mm (Value applies only if there is no ferromagnetic material in the vicinity of the read head and the actuator.) |
Repeat accuracy R | max. 10 % |
Electrical connection values
Rated insulation voltage Ui | 26.4 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Switching voltage | 24 V |
Switching voltage according to UL | |
according to UL Class 2 | max. 24 V AC/DC |
Switching current | 8 ... 500 mA |
Switching characteristics | NO + NC |
Mechanical values and environment
Connection type | Hard-wired encapsulated cable with cable end sleeves 0.34 mm2 |
Number NC contacts | 1 NC contact |
Number of NO contacts | 1 NO contacts |
Tightening torque | 0.4 ... 0.5 Nm |
Design | A |
Installation orientation | any |
Cable length | 3 m |
Mechanical life | 100 x 10⁶ |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP67 |
Ambient temperature | -20 ... +60 °C |
Material | |
Housing | Fiber glass reinforced PPS |
Cable material | PVC |
Method of operation | magnetic, reed contact |
Miscellaneous
in compliance with | EN ISO 13849-1:2015; EN 50178:1997; EN 60204-1:2006/A1:2009; EN ISO 14119:2013; EN 61000-6-2:2005; EN 61000-6-3:2007/A1:2011; EN 60947-5-3:2013 |
Aksesuar
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler
Declarations of conformity
EU-Konformitätserklärung
Dok. No.
Versiyon
Dil
Boyut
EU-Konformitätserklärung
Dok. No.
EDC2112987
Versiyon
Dil
Boyut
0,2 MB
UKCA-Konformitätserklärung
Dok. No.
Versiyon
Dil
Boyut
UKCA-Konformitätserklärung
Dok. No.
EDC20001569
Versiyon
Dil
Boyut
0,1 MB
Instructions
Operating Instructions Read Heads/Actuators for Evaluation Units CMS
Dok. No.
Versiyon
Dil
Boyut
Operating Instructions Read Heads/Actuators for Evaluation Units CMS
Mode d’emploi Têtes de lecture / actionneurs pour analyseurs CMS
Manual de instrucciones Cabezas de lectura/actuadores para unidades de evaluación CMS
Betriebsanleitung Leseköpfe/Betätiger für Auswertegeräte CMS
Mode d’emploi Têtes de lecture / actionneurs pour analyseurs CMS
Manual de instrucciones Cabezas de lectura/actuadores para unidades de evaluación CMS
Betriebsanleitung Leseköpfe/Betätiger für Auswertegeräte CMS
Dok. No.
2085673
Versiyon
17-11/23
Dil
Boyut
3,1 MB
Betriebsanleitung Leseköpfe/Betätiger für Auswertegeräte CMS
Dok. No.
2085673
Versiyon
17-11/23
Dil
Boyut
0,8 MB
Diğer Belgeler
Approvals and certificates
TUEV Süd München Z10 Zertifikat
Dok. No.
Versiyon
Dil
Boyut
TUEV Süd München Z10 Zertifikat
Dok. No.
Versiyon
Dil
Boyut
0,5 MB
c UL us
Dok. No.
Versiyon
Dil
Boyut
c UL us
Dok. No.
Versiyon
Dil
Boyut
1,0 MB
Sales documents
Interrupteurs de sécurité à codage magnétique CMS
Dok. No.
Versiyon
Dil
Boyut
Interrupteurs de sécurité à codage magnétique CMS
Dok. No.
090606
Versiyon
10-11/20
Dil
Boyut
5,8 MB
CAD Verileri
Sipariş verileri
Sip. No. | 084587 |
Makale adı | CMS-R-AXH-03V |
Ağırlık | 0,2kg |
Gümrük sınıfı | 85389099990 |
ECLASS | 27-27-24-02 Safety-related magnetic proximity switch |