EUCHNER – More than safety.
EUCHNER – More than safety.

RGBF06D12-502AM-M (Sip. No. 087097)

Series RGBF...AM, 12 mm, mechanical

  • With exterior diaphragm
  • Plunger spacing 12 mm
  • Upright housing according to DIN 43697
  • Degree of protection IP67 according to IEC 60529
RGBF06D12-502AM-M (Sip. No. 087097)

Açıklama

Exterior diaphragm

The exterior diaphragm protects the plunger guide against the entry of very fine dust (dust from grinding, casting, glass, etc.) and prevents the plunger from seizing. At the same time, plunger sticking, caused by resinous lubricating coolants, can be prevented with this exterior diaphragm version.

Switching element

ES 502 E

Snap-action switching contact 1 NC + 1 NO

Dimension drawing
Dimension drawing
Wiring diagram ES 502 E
Wiring diagram ES 502 E

Dimensional drawings

Dimensional drawings
1Operating point
2Free position
3Groove for sealing ring
4Number of plungers

Connection examples

Connection examples

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/6CCC_2020980305000540_CQC2008010305306206

Electrical connection values

Connection cross section 0.34 ... 1.5 mm²
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2.5 kV
Utilization category
AC-15 6 A 230 V
DC-13 6 A 24 V
AC-12 8 A 250 V
Short circuit protection according to IEC 60269-1 8A gG
Switching current
min. at DC 12V min. 10 mA
thermal rated current Ith 8 A

Mechanical values and environment

Approach speed 0.01 ... 20 m/min
Connection type
4 x M25 x 1.5
Number NC contacts 6
Number of switching elements 6
Number of NO contacts 6
Design upright, according to DIN 43697
Actuating element Chisel plunger (Operating point accuracy ± 0.002. The reproducible operating point accuracy refers to the axial travel of the plunger after the switching element ES 502 E has been run-in with approx. 2,000 operating cycles.)
Actuating force min. 20 N
Installation orientation any
Mechanical life 30 x 10⁶
Switching principle Snap-action switching contact (Contact closing time<4 ms contact bounce time<3 ms)
Degree of protection IP67
Plunger spacing 12 mm
Ambient temperature -5 ... +80 °C
Material
Housing Die-cast aluminum, anodized
Contact Silver alloy, gold flashed

Miscellaneous

Additional feature (Exterior diaphragm = AM. The exterior diaphragm provides additional protection for the plunger guide. Plunger sticking, primarily caused by resinous lubricating coolants, can be prevented by this AM version.)

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 2,1 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 087097
Makale adı RGBF06D12-502AM-M
Ağırlık 1,03kg
GTIN 4047048002722
Gümrük sınıfı 85365019000
ECLASS 27-27-06-02 Multi-position switch

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.