EUCHNER – More than safety.
EUCHNER – More than safety.

TP3-4141A024SEM4AS1 (Sip. No. 088256)

Safety switch TP AS1, plug connector M12 (closed-circuit current principle)

  • Auxiliary release on the front
  • Increased horizontal overtravel
  • Optionally without guard lock monitoring
TP3-4141A024SEM4AS1 (Sip. No. 088256)

Açıklama

Guard locking types

TP3

Closed-circuit current principle, guard locking by spring force. Release by control of AS-i output 0.

TP4

Open-circuit current principle, guard locking by control of AS-i output 0. Release by spring force.

Control of the guard locking solenoid

The guard locking solenoid is controlled by the control system via AS-Interface bus bit D0. In addition, the 24V connection can be switched safely.

AS-Interface inputs, version AS1

D0, D1

Door monitoring contact SK

D2, D3

Solenoid monitoring contact ÜK

AS-Interface outputs

D0

Guard locking solenoid

D1

LED red

D2

LED green

LED function display

  • The Power LED indicates the operating voltage on the bus.
  • The Fault LED indicates if a fault has been detected on the AS-Interface bus.
  • The green and the red LEDs can be controlled as required by the control system via the bus using bits D1 and D2.

Auxiliary release

This is used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.

Dimension drawing
Dimension drawing
Connector assignment
Connector assignment
Electromechanical safety switches in use

Dimensional drawings

Dimensional drawings
1Auxiliary release
2Locking screw
3LED indicator

Connection examples

Connection examples
View of plug side

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20CCC2024010305643586_SafetySwitch T_STc_UL_us_E155795_2/5DGUV_ET 20002_ET 20003Asi Interface_56201_

Electrical connection values

ASI operating current max. 45 mA
ASI data in
according to AS-i Safety at Work D0, D1, D2, D3 (see positively driven contact)
ASI data out
Guard locking solenoid D0 (1 = Solenoid energized)
LED red D1 (1 = LED on)
LED green D2 (1 = LED on)
AS-Interface auxiliary voltage
IEC 60742, PELV 24 V -15% ... +10%
Auxiliary current AS-Interface 300 mA
AS-Interface LED
green Power
red Fault
AS-Interface protocol ASi-3
AS-Interface slave type ID-Code: B, EA-Code: 7
ASI voltage 22.5 ... 30 ... 31.6 V
Solenoid duty cycle 100 %

Mechanical values and environment

Approach speed max. 20 m/min
Connection type
1 x Plug connector M12 (4-pin)
Number of door position positively driven contacts
according to AS-i Safety at Work 1 (D0,D1 / 1 = door closed)
Number of guard lock monitoring positively driven contacts
according to AS-i Safety at Work 1 D2,D3 (1 = locked)
Extraction force 20 N
Actuation frequency max. 1200 1/h
Actuating force 10 N
Installation orientation any
Vertical insertion depth 29.5 mm
Mechanical life 1 x 10⁶
Retention force 10 N
Switching principle Slow-action switching contact
Degree of protection IP67
Ambient temperature -20 ... +55 °C
Material
Contact Silver alloy, gold flashed
Housing Reinforced thermoplastic
Locking force Fmax 1300 N
Locking force FZh 1000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10DMission time
Monitoring of the guard position3x10620 y
Important! Values valid at DC-13 100 mA/24V
Monitoring of guard locking3x10620 y
Important! Values valid at DC-13 100 mA/24V


In combination with actuator ACTUATOR-P-GT

Horizontal insertion depth 28 mm
Vertical insertion depth 29.5 mm
Horizontal overtravel 2 mm
Vertical overtravel 1.5 mm

In combination with actuator ACTUATOR-P-GNT

Horizontal insertion depth 28 mm
Horizontal overtravel 7 mm

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 4,1 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 088256
Makale adı TP3-4141A024SEM4AS1
Ağırlık 0,464kg
Gümrük sınıfı 85365019000
ECLASS 27-27-26-03 Safety switch with guard control

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.