Series GLBF... 12 mm, mechanical
- Plunger spacing 12 mm
- Horizontal housing
- Degree of protection IP67 according to IEC 60529
- LED function display optional
Açıklama
Switching elements
ES 502 E | Snap-action switching contact 1 NC + 1 NO |
ES 508 | Slow-action switching contact 1 NC |
On the usage of safety switching elements, the dog distance must be maintained to achieve the positively driven travel. The dogs must be positively mounted according to EN ISO 14119, i.e. riveted, welded or secured in some other way against becoming loose.
LED function display (optional)
Function displays are available for the following voltage ranges (see accessories)
LE060 | 12 ... 60 V AC/DC |
LE110 | 110 V AC ±15% |
LE220 | 220 V AC ±15% |
Dimensional drawings
Connection examples
Connection examples
Connection examples
Teknik Veriler
Approvals
Electrical connection values
Connection cross section | 0.34 ... 1.5 mm² |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2.5 kV |
Utilization category | |
AC-12 Switching element ES502E | 8 A 250 V |
DC-13 | 6 A 24 V |
AC-15 | 6 A 230 V |
Short circuit protection according to IEC 60269-1 | 8A gG |
Switching current | |
min. at DC 24V, switching element ES508 | min. 10 mA (applies to station 1) |
min. at DC 12V, switching element ES502E | min. 10 mA (applies from station 2) |
thermal rated current Ith | 8 A |
Mechanical values and environment
Approach speed | 0.01 ... 40 m/min |
Connection type | |
4 x | M25 x 1.5 |
Number NC contacts | 3 |
Number of switching elements | 4 |
Number of NO contacts | 3 |
Number of positively driven contacts | 1 |
Design | horizontal |
Actuating element | Chisel plunger |
Actuating force | min. 20 N |
Installation orientation | any |
Mechanical life | 30 x 10⁶ |
Switching principle | |
Switching element ES502E | Snap-action switching contact (Contact closing time<4 ms, contact bounce time<3 ms; applies from station 2) |
Switching element ES508 | Slow-action switching contact (applies to station 1) |
Operating point accuracy | ± 0,002 (The reproducible operating point accuracy refers to the axial travel of the plunger after the switching element ES 502 E has been run-in with approx. 2,000 operating cycles.) |
Degree of protection | IP67 |
Plunger spacing | 12 mm |
Ambient temperature | -5 ... +80 °C |
Material | |
Housing | Die-cast aluminum, anodized |
Contact | Silver alloy, gold flashed |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
B10D | 20 x 10⁶ |
Miscellaneous
Additional information | Mixed contact assembly (On horizontal multiple limit switches, it is necessary to start with the safety station/s on the left side (view on the plunger side). If several safety stations are to be installed, these must be installed directly one after the other.) |
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler
Déclaration UE de conformité
Declaración de conformidad UE
EU-Konformitätserklärung
Dichiarazione UE di conformità
Déclaration UE de conformité
Declaración de conformidad UE
EU-Konformitätserklärung
Dichiarazione UE di conformità
Mode d’emploi Boîtiers multipistes de précision RG, GS, GL 12/16 mm
Betriebsanleitung Präzisions-Reihengrenztaster RG, GS, GL 12/16 mm
Istruzioni di impiego Finecorsa multipli di precisione RG, GS, GL 12/16 mm
Diğer Belgeler
CAD Verileri
Sipariş verileri
Sip. No. | 091151 |
Makale adı | GLBF04D12-1508-M |
Ağırlık | 0,819kg |
Gümrük sınıfı | 85365019000 |
ECLASS | 27-27-06-02 Multi-position switch |