EUCHNER – More than safety.
EUCHNER – More than safety.

CES-A-C5H-01 (Sip. No. 091458)

Non-contact safety switch CES-A-C5...

  • Safety switch with integrated evaluation electronics
  • Pulsed signals can be switched
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • Unicode
CES-A-C5H-01 (Sip. No. 091458)

Açıklama

Approach direction

Can be adjusted in 90° steps

Unicode evaluation

Each actuator is highly coded (unicode). The evaluation unit detects only actuators that have been taught-in. Additional actuators can be taught-in.

Category according to EN ISO 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN ISO 13849-1

LED indicator

STATE

Status LED

OUT/ERROR

Safety outputs status / diagnostics LED (combined)

Additional connection

OUT

Monitoring output (semiconductor)

Attention:

The actuating range may vary depending on the substrate material and installation situation.

Typical actuating range
(Only in combination with actuator CES-A-BBA, CES-A-BCA)

<p>Typical actuating range<br>(Only in combination with actuator CES-A-BBA, CES-A-BCA)</p>

For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the actuating range of the side lobes is not entered.

Typical actuating range
(Only in combination with actuator CES-A-BPA)

<p>Typical actuating range<br>(Only in combination with actuator CES-A-BPA)</p>

For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.

Dimension drawing
Dimension drawing
Connector assignment (view of connection side on the safety switch)
Connector assignment (view of connection side on the safety switch)
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1LED status indication
2LED status indication
3Active face

Connection examples

Connection examples

Connection examples

Connection examples

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20DGUV_ET 21020_ET21021TUEV Süd München_71322708_c_UL_us_E155795_3/2

Workspace

Repeat accuracy R
according to EN 60947-5-2 max. 10 %

Operating and display elements

LED display
Status - LED
Safety outputs status / diagnostics (combined)

Electrical connection values

Fuse
(external) operating voltage 0.25 ... 8 A
Rated insulation voltage Ui 300 V (Tested by the employers’ liability insurance association up to 75 V.)
Rated impulse withstand voltage Uimp 1.5 kV
Operating voltage DC 18 ... 24 ... 27 V DC regulated, residual ripple<5%
EMC protection requirements Acc. to EN 60947-5-3
Current consumption 80 mA
Degree of contamination (external, according to EN 60947-1) 3
Monitoring output OUT
Output type Semiconductor output, p-switching, short circuit-proof
Output voltage 0.8 x UB ... UB V DC
Switching current max. 20 mA
Safety outputs LA / LB
Fuse
external, safety circuit U(+LA) / U(+LB) 0.4 A medium slow-blow
Output type Semiconductor outputs, p-switching, short circuit-proof, electrically decoupled (To ensure safety, both safety outputs (LA and LB) must be evaluated.)
Output voltage
LOW U(LA) / U(LB) 0 ... 1 V DC
HIGH U(LB) U(+LB) - 1.5 ... U(+LB) V DC
HIGH U(LA) U(+LA) - 1.5 ... U(+LA) V DC
rated conditional short-circuit current max. 100 A
Discrepancy time
(between the operating points of both safety outputs) max. 120 ms
Utilization category
DC-13 Safety outputs LA / LB 24 V 400 mA
Switching load
according to UL max. DC 24 V, Class 2
Switching current
per safety output 1 ... 400 mA
Power supply output load
U(+LA) / U(+LB) 18 ... 24 ... 27 V DC

Mechanical values and environment

Dimensions according to EN 60947-5-2: (LxWxH) 131x40x40
Connection type M12 plug connector, 8-pin; shield can be connected
Tightening torque
Screws, read head mounting bracket max. 0.6 Nm
Fixing screws, housing max. 1 Nm
Ready delay max. 3 s (After the operating voltage is switched on, the semiconductor outputs are switched off and the monitoring outputs are set to LOW level during the ready delay.)
Installation orientation any
Switching frequency max. 1 Hz
Mounting distance
between read heads min. 80 mm
Response time
after change in the actuation status max. 180 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum OFF time for the safety outputs following removal of the actuator.)
Degree of protection IP65/IP67
Ambient temperature
with UB = 24 V DC -20 ... +55 °C
Dwell time min. 0.5 s (The dwell time of an actuator inside and outside the actuating range must be at least 0.5 s to ensure safe detection of internal faults in the evaluation unit (self-monitoring).)
Material
Housing Plastic, PBT

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionPL e-3.7x10-9420 y


Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures

In combination with actuator CES-A-BBA-071840, CES-A-BCA

Actuator distance s
Minimum distance for side approach direction min. 4 mm
Switch-on distance
with center offset m=0 20 mm (The values apply to surface mounting of the actuator.)
Secured switch-off distance sar max. 40 mm
Secured switching distance sao
with center offset m=0 min. 18 mm (The values apply to surface mounting of the actuator.)
Switching hysteresis 2 ... 3 mm (The values apply to surface mounting of the actuator.)

In combination with actuator CES-A-BPA-098775

Actuator distance s
Minimum distance for side approach direction min. 6 mm
Switch-on distance
with center offset m=0 22 mm (applies to surface mounting on aluminum; in a non-metallic environment, the typical operating distances increase to 30 mm.)
Secured switch-off distance sar max. 58 mm
Secured switching distance sao
with center offset m=0 min. 15 mm (applies to surface mounting on aluminum)
Switching hysteresis 1 ... 2 mm (applies to surface mounting on aluminum)

In combination with actuator CES-A-BDA-20

Actuator distance s
Minimum distance for side approach direction min. 5 mm
Switch-on distance
with center offset m=0 21 mm (in non-metallic environment)
Secured switch-off distance sar max. 41 mm
Secured switching distance sao
with center offset m=0 min. 19 mm (in non-metallic environment)
Switching hysteresis 2 ... 3 mm (in non-metallic environment)

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 6,3 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 091458
Makale adı CES-A-C5H-01
Ağırlık 0,354kg
GTIN 4047048000919
Gümrük sınıfı 85365019000
ECLASS 27-27-24-03 Safety-related transponder switch

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.