EUCHNER – More than safety.
EUCHNER – More than safety.

CEM-A-LH10K-S3 (Sip. No. 095170)

Read head CEM-A-LH10K-S3 with guard locking without guard lock monitoring with remanence

  • Read head with guard locking without guard lock monitoring
  • Locking force 1000 N
  • With remanence
  • Up to category 4 according to EN ISO 13849-1
CEM-A-LH10K-S3 (Sip. No. 095170)

Açıklama

Combination options

Suitable for connection to a CES-AZ evaluation unit

Approach direction

<p>Approach direction</p>

Typical actuating range

<p>Typical actuating range</p>

Note assured release distance sar = 20 mm for internal component failure. Safety outputs are safely switched off.

Dimension drawing
Dimension drawing
Connection solenoid operating voltage plug S1. A free-wheeling diode is already integrated into each CEM.
Connection solenoid operating voltage plug S1. A free-wheeling diode is already integrated into each CEM.
Connection solenoid operating voltage plug S1. A free-wheeling diode is already integrated into each CEM.
Connection solenoid operating voltage plug S1. A free-wheeling diode is already integrated into each CEM.

Dimensional drawings

Dimensional drawings
1Active face of read head
2Active face magnet

Connection examples

Connection examples

Connection examples

Connection examples
Evaluation unit CES
X1.1U
X1.2+U
X1.30 V/GND
X1.4Functional earth
X2.1LED +
X2.2-
X2.3LED 0 V
X2.4-
X3.1Data line
X3.3Data line
X3.4SH (screen)

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/5

Workspace

Secured switch-off distance sar max. 20 mm (in combination with evaluation unit CES-A-...B or CES-AZ-...B)
Secured switching distance sao
with center offset m=0 0 mm (in combination with evaluation unit CES-A-...B or CES-AZ-...B)
Center offset -2.5 ... +2.5 mm
Switching hysteresis
with center offset m=0 0.7 mm (in combination with evaluation unit CES-A-...B or CES-AZ-...B)

Electrical connection values

Power consumption 5.4 W
Operating voltage DC
UCM 24 V DC -15% ... +10%
Solenoid duty cycle 100 %
Current consumption
UB 225 mA

Mechanical values and environment

Connection type
X3, read head Plug connector M8x1, 3-pin, plug (with snap-action/screw terminal)
X1, solenoid (yellow LED integrated in the plug) Plug connector M8x1, 4-pin, plug (with snap-action/screw terminal)
X2, external LED Plug connector M8x1, 4-pin socket (with screw terminal)
Installation orientation any
Switching frequency
Solenoid max. 1 Hz
Adhesive force
due to remanence 40 N -25% ... +25%
Cable length max. 25 m
Read head material Plastic (PPS)
Mechanical life
in case of use as door stop, and 1 Joule impact energy 1 x 10⁶
Degree of protection IP67
Ambient temperature -25 ... +50 °C
Material
Housing Die-cast aluminum
Read head Plastic (PPS)
Solenoid Steel, nickel plated
Locking force F
(not monitored, in axial direction) at UCM=24 V 1000 N
Guard locking principle Open-circuit current principle

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 1,5 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 095170
Makale adı CEM-A-LH10K-S3
Ağırlık 0,863kg
Gümrük sınıfı 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.