EUCHNER – More than safety.
EUCHNER – More than safety.

CMS-R-BZB-03V (Sip. No. 097368)

Read heads design B for ESM, PVC

  • In combination with evaluation units ESM-BA...
  • Cube-shaped version, 36 x 26 mm
  • Connecting cable
  • Cable type: PVC
CMS-R-BZB-03V (Sip. No. 097368)

Açıklama

Alignment of read head and actuator

Operating diagram, design B

CMS-R-BZB

<p>CMS-R-BZB</p>
  • typ. operating distance
  • typ. release distance
Dimension drawing
Dimension drawing
Circuit diagram CMS-R-BZB… (not actuated)
Circuit diagram CMS-R-BZB… (not actuated)

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_5/2

Electrical connection values

Fuse
Power supply / safety contacts, external contact protection Fuse 10 A gG (Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..)
rated conditional short-circuit current 100 A (Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..)
Electrical switching frequency
at I_min = 10 mA max. 5 Hz (Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..)
At nominal current 8 A max. 0.1 Hz (Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..)
Switching voltage 24 ... 35 V (DC)
Switching voltage according to UL
according to UL Class 2 max. 24 V AC/DC
Switching current max. 100 mA
Switching characteristics parallel
Switching delay from state change max. 26 ms (Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..)

Mechanical values and environment

Connection type Hard-wired encapsulated cable with cable end sleeves 0.34 mm2
Number of NO contacts 2 NO contacts with internal fuse, 100 mA each
Tightening torque 0.4 ... 0.5 Nm
Design B
Installation orientation any
Cable length 3 m
Mechanical life 100 x 10⁶
Degree of protection IP67
Ambient temperature -20 ... +60 °C
Material
Cable material PVC
Housing Fiber glass reinforced PPS
Method of operation magnetic, reed contact

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Monitoring of the guard position
B10D 20 x 10⁶

Miscellaneous

in compliance with EN ISO 13849-1: 2015; EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015; EN ISO 14119: 2013; IEC 60947-5-3: 2013
Classification according to EN IEC 60947-5-3 M3D36AS1

In combination with read head ESM-BA201, ESM-BA202, ESM-BA203, ESM-BA301, ESM-BA302, ESM-BA303, ESM-BA201P, ESM-BA301P and actuator CMS-M-BH

Secured switch-off distance sar max. 20 mm (The assured release distance s_ar corresponds to the reset distance.)
Secured switching distance sao
with center offset m=0 min. 7 mm (Value applies only if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
Center offset
at s=3 mm read distance 2.5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 4,1 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 097368
Makale adı CMS-R-BZB-03V
Ağırlık 0,185kg
Gümrük sınıfı 85389099990
ECLASS 27-27-24-02 Safety-related magnetic proximity switch

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.