Safety switch TP, plug connector SR11, with door monitoring contact, escape release
- Auxiliary release on the front
- Escape release from the rear
- With door monitoring contact
- Increased horizontal overtravel
- Plug connector
Açıklama
Approach direction
Horizontal and vertical
Can be adjusted in 90° steps
Increased overtravel for horizontal approach direction
Solenoid operating voltage
- AC/DC 24 V +10%, -15%
Guard locking type
TP3 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. |
Switching element
2131 | Slow-action switching contact 2 NC + 1 NO + 1 NC (door monitoring contact) |
Auxiliary release
This is used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.
Escape release (C1993, long actuator shaft)
This is used for manual release of guard locking from the danger zone without tools. With identification of On/Off position.
Functional drawings
Dimensional drawings
1) | Auxiliary release |
2) | Locking screw |
3) | Escape release, basic position |
4) | Escape release, unlocked position |
Connection examples
Door monitoring | |
Solenoid monitoring |
Teknik Veriler
Approvals
Electrical connection values
Power consumption | 8 W |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Utilization category | |
DC-13 | 4 A 24 V |
AC-15 | 4 A 50 V |
Short circuit protection according to IEC 60269-1 | 4A gG |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Solenoid duty cycle | 100 % |
Switching voltage | |
min. at 10 mA | 12 V |
Switching current | |
min. at 24 V | 1 mA |
thermal rated current Ith | 4 A |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection type | |
1 x | Plug connector SR11 |
Number of door position NC contacts | 1 |
Number of guard lock monitoring NO contacts | 1 |
Number of guard lock monitoring positively driven contacts | 2 |
Extraction force | 20 N |
Actuation frequency | max. 1200 1/h |
Actuating force | 10 N |
Installation orientation | any |
Mechanical life | 1 x 10⁶ |
Retention force | 10 N |
Switching principle | Slow-action switching contact |
Degree of protection | IP65 |
Ambient temperature | -20 ... +55 °C |
Material | |
Housing | Reinforced thermoplastic |
Contact | Silver alloy, gold flashed |
Locking force Fmax | 1300 N |
Locking force FZh | 1000 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
B10D | Mission time | |
---|---|---|
Monitoring of the guard position | 3x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V | ||
Monitoring of guard locking | 3x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V |
PL | Maximum SIL | Category | Mission time | |
---|---|---|---|---|
Control of guard locking | Depending on external control of guard locking | 20 y |
Miscellaneous
C number | |
C1993 | Escape release long |
In combination with actuator ACTUATOR-P-GNT
Horizontal overtravel | 7 mm |
In combination with actuator ACTUATOR-P-GT
Horizontal overtravel | 2 mm |
Vertical overtravel | 1.5 mm |
Aksesuar
AE-K-A1-DULK1-84177
- Lock unique locking
- Key removable in “unlocked” and “locked” positions
AE-K-A1-IULK1-86236
- Identical locking
- Key removable in “unlocked” and “locked” positions
AE-K-A1-IUK2-109212
- Identical locking
- Key can be removed only in “unlocked” position
AE-K-A1-ILK1-121917
- Identical locking
- Key removable in “locked” position
AE-B-A1-02,0-096230
- Can be used as escape release or emergency release
- no automatic return
- Sheath length 2 m (rope length 6 m)
AE-B-A1-02,0-F-097747
- Can be used as escape release or emergency release
- automatic return
- Sheath length 2 m (rope length 6 m)
AE-B-A1-03,0-098313
- Can be used as escape release or emergency release
- no automatic return
- Sheath length 3 m (rope length 6 m)
AE-B-A1-04,0-098314
- Can be used as escape release or emergency release
- no automatic return
- Sheath length 4 m (rope length 6 m)
AE-B-A1-03,0-F-111233
- Can be used as escape release or emergency release
- automatic return
- Sheath length 3 m (rope length 6 m)
AE-B-A1-06,0-125582
- Can be used as escape release or emergency release
- no automatic return
- Rope length 6 m (without sheath)
AE-B-A1-06,0-F-124770
- Can be used as escape release or emergency release
- automatic return
- Rope length 6 m (without sheath)
RIEGEL 0 NP/TP OHNE RASTUNG
- Bolt for safety switch NP... and TP...A
- Steel bolt
- For doors hinged on the left or right
- Suitable for a door gap of approx. 6 mm
RIEGEL 1 NP/TP 1X RASTUNG ZU
- Bolt for safety switch NP...AS,TP...A and GP
- Steel bolt
- For doors hinged on the left or right
- Suitable for a door gap of approx. 15 mm
RIEGEL TP-AF
- Bolt for safety switch with escape release GP and TP
- Steel bolt
- For doors hinged on the right
- escape lever
- Detent knob in open position
- Suitable for a door gap of approx. 15 mm
RIEGEL TP-CF
- Bolt for safety switch GP and TP with escape release
- Steel bolt
- For doors hinged on the left
- escape lever
- Latching in open position
- Suitable for a door gap of approx. 15 mm
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler
Déclaration UE de conformité
Declaración de conformidad UE
EU-Konformitätserklärung
Dichiarazione UE di conformità
Déclaration UE de conformité
Declaración de conformidad UE
EU-Konformitätserklärung
Dichiarazione UE di conformità
Mode d’emploi Interrupteur de sécurité TP…
Manual de instrucciones Interruptor de seguridad TP…
Betriebsanleitung Sicherheitsschalter TP…
Diğer Belgeler
Sipariş verileri
Sip. No. | 097897 |
Makale adı | TP3-2131A024SR11C1993 |
Ağırlık | 0,607kg |
Gümrük sınıfı | 85365019000 |
ECLASS | 27-27-26-03 Safety switch with guard control |