EUCHNER – More than safety.
EUCHNER – More than safety.

TK1-4131AB024M (Sip. No. 099686)

Safety switch TK, locking pin right, closed-circuit current principle

  • Mounting on plastic housing TP with actuating head and locking pin made of metal
  • High locking forces of 5000 N
  • Auxiliary release on the switch head
  • Actuating element for contact separation on the front
  • Cable entry M20 x 1.5
TK1-4131AB024M (Sip. No. 099686)

Açıklama

Solenoid operating voltage

  • AC/DC 24 V +10%, -15%

Guard locking type

TK1

Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid.

Switching element

4131

Slow-action switching contact 2 NC + 2 NO

Auxiliary release

This is used for releasing the guard locking with the aid of a tool.

Contact separation

When actuated, positively driven contacts 21-22 and 41-42 are opened. Guard locking is not fully unlocked. The auxiliary release must be sealed to prevent tampering (e.g. with sealing lacquer).

Switching function
Switching function
Dimension drawing
Dimension drawing
Wiring diagram 4131 (without door monitoring contact)
Wiring diagram 4131 (without door monitoring contact)
Electromechanical safety switches in use

Functional drawings

Functional drawings

Dimensional drawings

Dimensional drawings
1Auxiliary release on both sides
2Contact separation

Connection examples

Connection examples
Solenoid monitoring

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20CCC2024010305643586_SafetySwitch T_STc_UL_us_E155795_2/1

Electrical connection values

Power consumption 8 W
Connection cross section 0.34 ... 1.5 mm²
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2.5 kV
Utilization category
DC-13 4 A 24 V
AC-15 4 A 230 V
Short circuit protection according to IEC 60269-1 4A gG
Solenoid operating voltage
AC/DC 24 V -15% ... +10%
Solenoid duty cycle 100 %
Switching voltage
min. at 10 mA 12 V
Switching current
min. at 24 V 1 mA
thermal rated current Ith 4 A

Mechanical values and environment

Approach direction A
Connection type
3 x M20 x 1.5
Number of guard lock monitoring NO contacts 2
Number of guard lock monitoring positively driven contacts 2
Actuation frequency max. 1200 1/h
Installation orientation any
Mechanical life 1 x 10⁶
Switching principle Slow-action switching contact
Degree of protection IP67
Ambient temperature -20 ... +55 °C
Material
Contact Silver alloy, gold flashed
Housing Reinforced thermoplastic
Locking force Fmax 5000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10DMission time
Monitoring of guard locking2x10620 y
Important! Values valid at DC-13 100 mA/24V


PLMaximum SILCategoryMission time
Control of guard lockingDepending on external control of guard locking20 y


İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 3,3 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 099686
Makale adı TK1-4131AB024M
Ağırlık 0,601kg
Gümrük sınıfı 85365019000
ECLASS 27-27-26-03 Safety switch with guard control

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr

Çerez bildirimi

Web sitesinin çalışması için gerekli olan teknik olarak gerekli çerezleri kullanıyoruz. Buna ek olarak, web sitemizin kullanımını analiz etmek ve teklifimizi sürekli olarak iyileştirmek için bir istatistik çerezi kullanıyoruz. İstatistik çerezinin kullanımına izin vermek isteyip istemediğinize kendiniz karar verebilirsiniz. Daha fazla bilgiyi gizlilik politikamızda bulabilirsiniz.